Permit Review Detail
Review Status: Completed
Review Details: DEV PKG - OK TO SUBMIT
Permit Number - DP17-0137
Review Name: DEV PKG - OK TO SUBMIT
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/01/2020 | SBEASLE1 | START | PLANS SUBMITTED | Completed | |
| 05/04/2020 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Steve Shields Section Manager PROJECT: Casitas De Cafe Development Package (Revision) DP17-0137 TRANSMITTAL DATE: May 4, 2020 DUE DATE: Revison OK to Submit. COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM). 1. Which building footprints changed. 2. Could not find the metal fences on the plan, cleary show them. 3. 2-06.4.9.A - Where is the proposed lot line at. Until it is clarified and the number of proposed lots is verified the process required to divide this parcel cannot be determined. 4. 2-06.4.9.O - Based on the new building height provided the required perimeter yard setback to the north and west property line is 17'-8", revise the setbacks shown on the plan. 5. 2-06.4.9.O - Based on the new building height provided the required street perimeter yard setback to both streets is 23'-6", revise the setbacks shown on the plan. 6. 2-06.4.9.Q - As the height of the proposed covered parking was not provide required perimeter yard setbacks cannot be verified. It appears that the structures shown along Brown Ave will not meet the minimum 21' required setback. Also per UDC Article 6.6.3.B etached accessory buildings are not permitted in the buildable area extending the full width of the lot between the principal building and the front street lot line, except for terraces and steps not over three feet high above the natural grade, paved areas, and fences or walls 7. 2-06.4.9.R - Provide width dimension for all sidewalks on this plan including the sidewalk between buildings 4 & 34 and the parking area. Per TSM Section 7-01.4.3.A the minimum width of a sidewalk is 4'-0". If you are proposing to reduce the width to less than 4'-0" a Technical Standards Modification Request (TSMR) must be submitted and approved prior to approval of this DP revision. 8. 2-06.4.9.R - Provide wheel stops to prevent vehicles from reducing the sidewalk width to less than 4'-0". If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package |
| 05/04/2020 | LOREN MAKUS | ENGINEERING | REVIEW | Denied | DP17-0137 Revision 1. Provide sheets showing dimensions of features affected by the revision. 2. The revisions letter indicates the space between the parking and buildings 4 and 34 has been reduced to 3 feet. TS 7-01.4 requires 4-foot sidewalks in this area. 3. Show parking blocks to prevent vehicles from reducing the width of the pedestrian circulation path. 4. Additional comments may be forthcoming once dimensioned sheets are included. Loren Makus, EIT loren.makus@tucsonaz.gov |
| 05/04/2020 | SBEASLE1 | ZONING-DECISION LETTER | WRITE DECISION LETTER | Reqs Change | REVISION PLAN RETURNED FOR CORRECTIONS/DENIED FOR REVIEW NOTICE - A resubmittal is required Project Description: SITE/GRADING/SWPPP - Casitas de Cafe, units 1-34. Permit: SITE/GRADING/SWPPP - Casitas de Cafe, units 1-34. View the reviewer's comments and documents on PRO: www.tucsonaz.gov/pro (If information is not available, check back later after data transfers to PRO.) - Home page, left side, Activity Search, enter the Activity Number - Permits section, click on blue tab - Documents section, click on blue icon to the right of each document - Reviews section, click on Review Details After the corrections are made, please name your Revision #1, 2nd submittal documents accordingly, for example: REV-1_2_Plan_Set. YOUR NEXT STEPS: Submit the following items to the Filedrop- https://www.tucsonaz.gov/file-upload-pdsd 1) Comment Response Letter (your response to the reviewer's Requires changes comments) 2) Plan Set (or individual sheets) 3) Any other items requested by review staff CONTACT US Monday-Friday, 8:00 am to 12:00 noon https://www.tucsonaz.gov/pdsd/virtual-service-counter To request information or an over-the-counter review, sign in to the Virtual Service Counter and we will give you a call. Thank you. Sharon Beasley, Permit Specialist City of Tucson Planning and Development Services email: COTDSDPermits@TucsonAz.gov |