Permit Review Detail
Review Status: Completed
Review Details: DEV PKG - RESUBMITTAL
Permit Number - DP17-0130
Review Name: DEV PKG - RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/08/2017 | JOHN BEALL | COT NON-DSD | COMMUNITY PLANNING | Approved | |
| 08/08/2017 | LOREN MAKUS | ENGINEERING | REVIEW | Approved | |
| 08/08/2017 | DAVID RIVERA | ZONING | REVIEW | Approv-Cond | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: David Rivera for Steve Shields - Principal Planner PDSD Zoning Review Section PROJECT: Chamberlain Parking Expansion Development Package (2nd Review) DP17-0130 TRANSMITTAL DATE: August 8, 2017 DUE DATE: August 8, 2017 COMMENTS: DP17-0130 has been conditionally approved by Zoning, see follow up comment number 1. Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is June 9, 2018. 1. Follow Up To Previous Comment 8: The dedication recordation information for the 50-foot non-motorized trail "Rezoning condition 14" must be listed on the plan prior Mayor and Council agenda. It is acknowledged the recordation for the roadway has been listed as requested on the previous comment. 2-06.4.9.I - Show all right-of-way dedications on or abutting the site and label. If the development package documents have been prepared in conjunction with a subdivision plat or is required as a condition of approval of a review process, such as a rezoning, street dedications in accordance with the Major Streets and Routes (MS&R) Plan may be required by these processes. Projects bounded by streets having only a portion of the right-of-way width dedicated will be required to dedicate right-of-way, up to one-half, to complete the street width. Should there be any proposed street or alley vacation, provide this information. If vacation has occurred, include the recording information. PREVIOUS COMMENT 8: Clarify if the recordation of easements and dedication of right of way is to be recorded prior to approval of the DP under separate instruments or is the intent to prepare the documents and record them at time of M & C approval of the DP? Additional comment s may be forthcoming on this item. If you have any questions about this transmittal, Contact David Rivera on Tuesday or Wednesday at (520) 837-4957 or by email David.Rivera@tucsonaz.gov or contact Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov |
| 08/08/2017 | ARUIZ1 | START | PLANS SUBMITTED | Completed | |
| 08/08/2017 | DAVID RIVERA | ZONING HC | REVIEW | Approved | |
| 08/14/2017 | ANDREW CONNOR | LANDSCAPE | REVIEW | Approved | |
| 08/16/2017 | GLENN HICKS | COT NON-DSD | PARKS & RECREATION | Approved | All previous Tucson Parks and Recreation comments have been adequately addressed. Tucson Parks and Recreation recommends approval of this development package. Howard B. Dutt, RLA Landscape Architect Tucson Parks & Recreation (520) 837-8040 Howard.Dutt@tucsonaz.gov |
| 08/16/2017 | KELLY LEE | OTHER AGENCIES | TUCSON AIRPORT AUTHORITY | Approved | |
| 10/24/2017 | KELLY LEE | ZONING-DECISION LETTER | REVIEW | Approved | This review has been completed with a condition approval and resubmittal is required. This may be conducted as an "over the counter review" subject to the reviewers discretion. Please contact us to set an appointment and resubmit the following items: 1) Two rolled sets of the plans 2) All approved documents submitted previously 3) A disk containing all items submitted 4) All items requested by review staff 5) All items needed to approve these plans |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 10/25/2017 | KROBLES1 | OUT TO CUSTOMER | Completed |