Permit Review Detail
Review Status: Completed
Review Details: DEV PKG - RESUBMITTAL
Permit Number - DP17-0128
Review Name: DEV PKG - RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/22/2019 | SBEASLE1 | START | PLANS SUBMITTED | Completed | |
| 08/05/2019 | SBEASLE1 | OTHER AGENCIES | TUCSON AIRPORT AUTHORITY | Approved | August 5, 2019 Sharon Beasley, Permit Technician City of Tucson Public Works Buildings - 201 North Stone Avenue Tucson, AZ. 85701 RE: DP17-0128 Light Industrial Facility, 1560 E. 17th Street, 6th Submittal, Received July 22, 2019 Dear Ms. Beasley, Thank you for the opportunity to comment on DP17-0128, Light Industrial Facility, 1560 E. 17th Street, 6th submittal, a development package application for an approximately 0.85 acre site, located southeast of the intersection of South Vine Avenue and East 17th Street, with the project site being immediately northwest of the intersection of South Kino Parkway and East Aviation Parkway (SR-210). The property is zoned Industrial 1 (I-1), with the proposed development being a light industrial building. This site is within the Tucson International Airport avigation easement requirements and public disclosure area, FAA traffic pattern airspace, and FAA Part 77 airspace. The Tucson Airport Authority is satisfied with the 6th submittal of the project and has no further comments to provide. Please do not hesitate to contact me if you have any questions or concerns regarding this comment letter. I can be reached by email at srobidoux@flytucson.com or by telephone at 520-573-4811. Respectfully, Scott Robidoux, Senior Airport Planner |
| 08/14/2019 | SAMUEL ROGERS | ZONING | REVIEW | Reqs Change | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Samuel Rogers PDSD Zoning Review Section PROJECT: 17th Street Facility - General Manufacturing use Development Package (1st Review of revised development package) DP17-0128 - I-1 Zoning / 1560 E. 17 Street TRANSMITTAL DATE: 8/14/2019 DUE DATE: 8/20/2019 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is May 31, 2019. ***This corrected DP was reviewed as a new submittal for compliance with AM 2-06. Address the following zoning comments and resubmit. Address the follow up comments 1 - 2 of this review. Include any documentation requested by zoning 1. Follow up to previous comment 1: The project location map must include the section corners notated on each corner of the map. An email will be sent to rburton3@cox.net to clarify the requirement. 2-06.4.4.C - Section, township, and range; section corners; north arrow; and the scale will be labeled. 2. Follow up to previous comment 3: All lots must be combined and a signed Parcel Combo Form of approval or acceptance from the Pima County Assessor's office must be included in the next submittal. Additionally, the current plans do not match the legal description exhibit on Sheet 6. The former easement extended to Line L5 per the legal description exhibit, ensure plans reflect these dimensions. 2-06.4.8.A - Provide site boundary/subdivision perimeter information, including bearing in degrees, minutes, and seconds, with basis for bearing noted, together with distances in feet, to hundredths of a foot, or other functional reference system. 3. If lot combo documentation is presentation at the time of uploading the next submittal, the plan may be reviewed over the counter. If you have any questions about this transmittal, Contact Samuel Rogers at (520) 837-6932 or by email sameul.rogers@tucsonaz.gov or contact Steve Shields at (520) 837-4956 or email Steve.Shields@tucsonaz.gov RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package |
| 08/16/2019 | SBEASLE1 | ZONING-DECISION LETTER | REVIEW | Reqs Change | PLAN RETURNED FOR CORRECTIONS NOTICE - The reviews have been completed - A resubmittal is required Permit/Activity Number: DP17-0128 Description: SITE/GRADING - 17th Street facility. The fee balance is $0 (zero). To view the review comments: www.tucsonaz.gov/PRO, enter Activity Number. (If information isn't shown yet, check back later as data flows to PRO periodically throughout the day.) Name your 7th submittal documents accordingly, for example: 7_Plan_Set. Submit the following items to the PDSD Filedrop: https://www.tucsonaz.gov/file-upload-pdsd. In the Project Description field, please include the Activity Number. 1) Comment Response Letter (listing your response to reviewer's comments) 2) Plan Set (all pages, full set) 3) Any other items requested by review staff Thank you. Sharon Beasley, Permit Specialist City of Tucson Planning and Development Services Attn: Permit Counter/Payments 201 N. Stone Avenue, First Floor Tucson, AZ 85701 |
| 08/16/2019 | ANDREW CONNOR | LANDSCAPE | REVIEW | Reqs Change | This comment was not fully addressed from previous review. Street landscape borders are required along 17th Street and Cherry. At least 5' must be located on-site. Indicate how this comment is addressed or variance must be applied for. Not all of the required landscaping and screening can be located within the ROW move some of it onsite. Please set up an appointment for explination of comments. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 08/16/2019 | SBEASLE1 | OUT TO CUSTOMER | Completed |