Permit Number: DP17-0118
Parcel: 122170480

Address:
1135 N JONES BL

Review Status: Completed

Review Details: RESUB - SITE and/or GRADING

Permit Number - DP17-0118
Review Name: RESUB - SITE and/or GRADING
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/11/2017 STEVE SHIELDS ZONING REVIEW Reqs Change CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Steve Shields
Principal Planner

PROJECT: Connections AZ MAT Clinic
Development Package (1st Review)
DP17-0118

TRANSMITTAL DATE: July 11, 2017

DUE DATE: Walk Though

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

2-06.4.9 - Information on Proposed Development
The following information on the proposed project shall be shown on the drawing or added as notes.

1. 2-06.4.9.A - As this site is made up of two (2) parcels, 122-17-0480 & 122-17-0470a lot combination is required. Provide a copy of the approved Pima County Combo Request form with your next submittal.

2. 2-06.4.9.H.5 - Per UDC Article 7.4.6.H.1 Barriers, such as post barricades or wheel stop curbing, are required in a vehicular use area to prevent vehicles from extending beyond the property lines, to prevent cars from damaging adjacent landscaping, walls, or buildings, overhanging adjacent sidewalk areas, and/or driving onto unimproved portions of the site. Demonstrate on the plan how this requirement is met along the north and south side of the parking area.

3. 2-06.4.9.H.5.a - Provide a wheel stop location dimension on the plan, see UDC Article 7.4.6.H.3.

4. 2-06.4.9.H.5.a - Fully dimension the accessible vehicle parking spaces. It does not appear that the requirements for a van accessible space are met, see 2012 IBC Chapter 11 Section 1106.5 and ICC A117.1-2009 Section 502.

5. 2-06.4.9.R - Clearly show the accessible route from the accessible access aisle to the accessible sidewalk and to each building.

Once the above comments are addressed Zoning will provide an over -the-counter review. Call or email to schedule an appointment for the review.

If you have any questions about this transmittal, please Name, (520) 837-PHONE or email@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
07/11/2017 SSHIELD1 HC SITE REVIEW Reqs Change See Zoning comments
07/11/2017 ANDREW CONNOR NPPO REVIEW Reqs Change Submit a NPP plan or the following:
2-11.3.0 PERMITTED EXCEPTIONS
Requests for exceptions from the Native Plant Preservation requirements in accordance with Sections 7.7.3.D.3 and .4 of the UDC are reviewed by the Planning and Development Services Department (PDSD). Submittals are required to document that the site does not contain, or the proposed project does not impact, Protected Native Plants. Submittal requirements shall consist of one or more of the following items:
A signed statement from one of the plant professionals listed in Section 7.7.4.D, Professional Expertise, of the UDC who has visited the site and verified that Viable Protected Native Plants are not located on the subject site
07/11/2017 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Completed
07/11/2017 ANDREW CONNOR LANDSCAPE REVIEW Reqs Change Submit a NPP plan or the following:
2-11.3.0 PERMITTED EXCEPTIONS
Requests for exceptions from the Native Plant Preservation requirements in accordance with Sections 7.7.3.D.3 and .4 of the UDC are reviewed by the Planning and Development Services Department (PDSD). Submittals are required to document that the site does not contain, or the proposed project does not impact, Protected Native Plants. Submittal requirements shall consist of one or more of the following items:
A signed statement from one of the plant professionals listed in Section 7.7.4.D, Professional Expertise, of the UDC who has visited the site and verified that Viable Protected Native Plants are not located on the subject site
07/11/2017 LOREN MAKUS ENGINEERING REVIEW Approved
07/17/2017 ARUIZ1 FIRE REVIEW Needs Review