Permit Review Detail
Review Status: Completed
Review Details: SITE and/or GRADING
Permit Number - DP17-0101
Review Name: SITE and/or GRADING
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/28/2017 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Steve Shields Principal Planner PROJECT: 1039 N. 6th Avenue - Accessible Ramp Development Package (1st Review) DP17-0101 TRANSMITTAL DATE: April 28, 2017 DUE DATE: Walk Through COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM). Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is April 27, 2018. 1. 2-06.4.3 - Provide the development package case number, DP17-0101 , adjacent to the title block on all sheets. 2. 2-06.4.3 - Provide the historic case number adjacent to the title block on all sheets. 3. 2-06.4.7.A.6 - As this project is located within the HO-3 zone and exterior work is proposed Historic review is required. Contact Michael Taku for process and fees, (520) 837-4963 Michael.Taku@tucson az.gov. Once the historic review is completed provide a general note on the plan stating the historic case number, date of approval, and if applicable any conditions of approval. Also the development package will need to be stamped by the historic section prior to approval by Zoning. 4. 2-06.4.9.H.5 - Per UDC Article 7.4.6.F.4 a back-up spur is required at the north end of the PAAL just west of the proposed accessible vehicle parking space. 5. 2-06.4.9.H.5 - Provide a PAAL width dimension from the west end of the proposed accessible vehicle parking space to the angled spaces to the west. 6. 2-06.4.9.H.5.a - Some type of barrier is required to prevent vehicles that are parking in the accessible vehicle parking space from accessing the unimproved areas of the site, see UDC Article 7.4.6.H.1 7. 2-06.4.9.H.5.a - Show the required accessible sign on the plan and provide a detail for the sign on the plan. 8. 2-06.4.9.R - Provide a ramp railing detail that demonstrates how the requirements of ICC A117.1-2009 Section 505 are met. 9. 2-06.4.9.R - Provide a note on the plan stating that all accessible route slopes are to comply with ICC A117.1, Section 403.3; 5% maximum running slopes and 2% maximum cross slopes. 10. Provide a copy of the last approved site plan with your next submittal. If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package |
| 04/28/2017 | SSHIELD1 | H/C SITE | REVIEW | Reqs Change | See Zoning comments |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 05/31/2017 | ARUIZ1 | OUT TO CUSTOMER | Completed |