Permit Number: DP17-0089
Parcel: 136328050

Review Status: Completed

Review Details: GRADING

Permit Number - DP17-0089
Review Name: GRADING
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
05/24/2017 LOREN MAKUS ENGINEERING REVIEW Reqs Change 1. Clearly show the grades at tops and toes of proposed cut and fill slopes. For example, at the top of the driveway the existing contour is about 6 feet above the proposed garage floor elevation.
2. Show sufficient spot grades along the driveway and across the building pad to establish slopes.
3. Show the extent and slopes of runout from the graded areas to natural grade.
05/24/2017 ANDREW CONNOR ZONING REVIEW Reqs Change Ensure that all Enginerring comments and concerns are addressed prior to Zoning approval.
05/24/2017 ANDREW CONNOR NPPO REVIEW Reqs Change 5.2. HILLSIDE DEVELOPMENT ZONE (HDZ)
Add the following notes to the site plan:
Vegetation Retention and Revegetation
a. Vegetation Retention
(1) Existing viable and transplantable trees with four inch or greater trunk diameter and cacti shall be preserved in their original locations, except for building sites and access and utilities serving building sites.
(2) When retention of the above trees and cacti in their original locations is not possible due to building site location, the trees and cacti shall be salvaged and replanted in areas requiring revegetation, whenever possible.
b. Revegetation
All cut or fill slopes that are no steeper than three horizontal to one vertical and all utility trenches or septic leaching fields that are not located in parking or driveway areas shall be revegetated in compliance with the following standards:
(1) All plants used in revegetation shall be the same as the native vegetation on the site prior to grading or clearing or any adjacent site; and,
(2) Revegetation shall be accomplished with the following minimum standards for plants:
(a) Desert trees, a minimum of 15-gallon size with a minimum trunk diameter of two inches measured at the soil level, or large specimen cactus shall be placed at the same vegetation density found on the site prior to any clearing, grubbing, or grading; and,
(b) Seeds for trees, desert shrubs, and grasses shall be planted with a density adequate to control erosion and may use one of the following methods of planting: Raked into the soil with appropriate mulch materials; hydroseeding; anchored mulches; or established on jute, rolled straw, or similar material. Another method may be approved by PDSD.
(3) A temporary watering system shall be installed until the revegetation materials are established.
3. Slope Stabilization
All slopes steeper than a ratio of three horizontal to one vertical, with the exception of retaining walls, shall be stabilized with properly engineered stone riprapping or sculptured rock as follows:
a. Stone riprapping shall be hand-placed on the slope;
b. The stabilizing material used shall blend with the natural appearance of the site or lot and the surrounding terrain; and,
c. Vegetation retention and revegetation should be used in conjunction with riprapping.

Ensure that all Engineering comments are addressed.

Final Status

Task End Date Reviewer's Name Type of Review Description
05/31/2017 AMORALE3 OUT TO CUSTOMER Completed