11/09/2017 KROBLES1 START PLANS SUBMITTED Completed
11/14/2017 ALEXANDRA HINES OTHER AGENCIES TUCSON AIRPORT AUTHORITY Approved
12/05/2017 STEVE SHIELDS ZONING REVIEW Reqs Change CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Steve Shields
Principal Planner

PROJECT: First Five
Development Package (1st Review)
DP17-0036

TRANSMITTAL DATE: December 5, 2017

DUE DATE: December 11, 2017

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is February 12, 2018.

CONTENT REQUIREMENTS

2-06.4.9 - Information on Proposed Development
The following information on the proposed project shall be shown on the drawing or added as notes.

1. Some type of easement is required to allow vehicle access across both properties. 2-06.4.9.H.5.a - Per 8.7.3.I.2 an alley abutting and existing development cannot be used to access vehicle parking. That said the proposed access off of the alley to Lots 1 & 2 is not allowed.

2. Provide copies of the CC&R's 2-06.4.9.L - There is a proposed "14' PRIVATE SEWER EASEMENT" shown on the plan. Provide documentation, addressing maintenance /repair of the proposed site walls shown within the easement if maintenance is required on the private sewer.

2-06.5.0 FLEXIBLE LOT DEVELOPMENT (FLD - ADDITIONAL REQUIREMENTS)

2-06.5.3 Additional Information
The following are required in addition to the requirements of the tentative plat or site plan, whichever is applicable:
3. 2-06.5.3.G.1 - Provide three copies of the Covenants, Conditions, and Restrictions (CC&Rs) regarding the homeowner's association's responsibility for the ownership and maintenance of commonly-owned property.

Once the above comments are addressed Zoning will provide an over the counter review. Call or email to schedule an appointment for this review.

If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
12/06/2017 JENNIFER STEPHENS PIMA COUNTY ADDRESSING Approv-Cond DP17-0036 First Five / 2nd Submittal is Conditionally Approved by Pima County Address subject to the legal description being corrected as follows:





Legal description should read:

“SOUTHERN HEIGHTS ADDITION” LOT 2 OF BLOCK 1, PER BK.2, PG.20 AND “NATIVE AMERICAN ADDITION” LOT 11 OF BLOCK 2, PER BK.2, PG.11…



Please let me know if you have any questions.

Thank you,



Robin Freiman

Addressing Official

Pima County Development Services Department

201 N Stone AV – 1st Floor
Tucson, AZ 85701

(520) 724-7570
12/08/2017 ANDREW CONNOR LANDSCAPE REVIEW Reqs Change Transportation approval for landscaping within ROW is required.

Ensure that all Zoning and Engineering comments and concerns are addressed prior to landscape approval.
12/12/2017 KELLY LEE UTILITIES TUCSON ELECTRIC POWER Approved Tucson Electric Power Co., (TEP) has reviewed and approves the 2nd submittal of the Tentative Plat for First Five Subdivision. Removal or relocation of existing TEP facilities will be billable to the Developer.



If you have any questions, please contact me at 520-917-8744.



Thank you,



Mary Burke

Right of Way Agent III

Tucson Electric Power Co.

Land Resources – RC 131

3950 E. Irvington Road

Tucson, AZ 85714-2114

Office - 520-917-8744

Cell - 520-401-9895

mburke@tep.com
12/13/2017 LOREN MAKUS ENGINEERING REVIEW Approved
12/14/2017 KELLY LEE ZONING-DECISION LETTER REVIEW Reqs Change This review has been completed and resubmittal is required. Please resubmit the following items:
1) Two rolled sets of the plans
2) All approved documents submitted previously
3) A disk containing all items submitted
4) All items requested by review staff
5) All items needed to approve these plans

Final Status

Task End Date Reviewer's Name Type of Review Description
11/09/2017 ANY REJECT SHELF RECEIVED