Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: DP17-0024
Parcel: 13409013A

Review Status: Completed

Review Details: TENTATIVE PLAT REVIEW

Permit Number - DP17-0024
Review Name: TENTATIVE PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
05/08/2017 LBOJORQ1 START PLANS SUBMITTED Completed
05/09/2017 ALEXANDRA HINES PIMA COUNTY WASTEWATER Approved To: Richard Macias
Coronado Engineering.
zasX
____________________________________
From: Hussein Al Zubaidi, RWRD (520) 724-6404

Subject: Camino Seco Subdivision
P17WS00014 (DP17-0024
PSL-1ST Submittal

The Pima County Regional Wastewater Reclamation Department (PCRWRD) has reviewed the proposed sewer design for the above-referenced project. The Pima County Regional Wastewater Reclamation Department hereby approves the above referenced submittal of the Preliminary Sewer Layout (PSL), based upon PCRWRD Engineering Design Standards (EDS) 2016.

If you have any questions regarding this matter please contact me at your convenience.

Cc. Lorenzo Hernandez, P.E., RWRD
Tom Porter, P.E., RWRD
Francisco Galindo, P.E., RWRD
05/11/2017 PAUL BAUGHMAN ENGINEERING REVIEW Reqs Change Process differential grading request per previous comment and response number 16.

Process TSMR for alternate curb and detention in lieu of retention per previous comments and response numbers 4 and 14.
05/15/2017 ALEXANDRA HINES PIMA COUNTY ADDRESSING Approv-Cond DP17-0024 Camino Seco Subdivision / 2nd Submittal is Approved by Pima County Addressing subject to the following:

· Please correct spelling of Plat Name in the legal description

· Provide updated title report to verify ownership

Please let me know if you have any questions.

Thank you,

Robin Freiman
Addressing Official
Pima County Development Services Department
201 N Stone AV – 1st Floor
Tucson, AZ 85701
(520) 724-7570
05/16/2017 MARTIN BROWN COT NON-DSD FIRE Approved
05/17/2017 STEVE SHIELDS ZONING REVIEW Reqs Change CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Steve Shields
Principal Planner

PROJECT: Camion Seco Subdivision
Development Package (2nd Review)
DP17-0024

TRANSMITTAL DATE: Revised June 6, 2017

DUE DATE: June 02, 2017

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is January 26, 2018.

2-06.4.7 - General Notes
The following general notes are required. Additional notes specific to each plan are required where applicable.

2-06.4.7.A - Zoning and Land Use Notes

1. This comment was not addressed. 2-06.4.7.A.6.a - As a Technical Standard Modification Request (TSMR) will be required for this project provide the TSMR case number adjacent to the title block on all sheets. Also provide a General Note stating the case number, date of approval, what was modified, and if applicable any conditions of approval.

2-06.4.7.A.8 - For development package documents provide:

2-06.4.9 - Information on Proposed Development
The following information on the proposed project shall be shown on the drawing or added as notes.

2. This comment was not addressed. 2-06.4.9.H.7 As the proposed private streets do not match any of the figures located in TSM Section 10-01.9.0 a TSMR will need to be approved for width, vehicles backing out of visitors parking spaces directly into the street and elimination of required sidewalks.

3. This comment was not fully addressed, provide the recordation information on the plan. 2-06.4.9.I - It appears that alley vacation is proposed along the west side of this plan. Clearly show what is proposed and provide the recordation information on the plan.

2-06.5.0 FLEXIBLE LOT DEVELOPMENT (FLD - ADDITIONAL REQUIREMENTS)

2-06.5.3 Additional Information
The following are required in addition to the requirements of the tentative plat or site plan, whichever is applicable:

4. The reduced street perimeter yard setbacks have been approved by the PDSD Director subject to additional color variations being provided for all street building elevations. 2-06.5.3.A - The proposed reduced interior street perimeter yard setbacks will need to be approved by the PDSD Director, UDC Article 8.7.3.L.2, prior to approval of the development package.

5. This will need to be approved prior to approval of the development package. 2-06.5.3.E - The Architectural Variation Plan will need to be approved prior to approval of the development package.

6. This comment was not addressed. 2-06.5.3.G.1 - Provide the required copies of the CC&Rs with your next submittal.

Once the above comments have been addressed Zoning will provide an over-the-counter review. Call or email to schedule an appointment for this review.

If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
05/17/2017 ED ABRIGO PIMA COUNTY ASSESSOR Reqs Change Office of the Pima County Assessor
115 N. Church Ave.
Tucson, Arizona 85701

BILL STAPLES
ASSESSOR




TO: CDRC Office
Subdivision Review
City of Tucson


FROM: Ada Griffin
GIS Cartographer
Pima County Assessor's Office


DATE: May 17, 2017


RE: Assessor's Review and Comments Regarding:

DP17-0024 Camino Seco Subdivision / 2nd Submittal

_

* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *

Plat meets Assessor's Office requirements.
___X___ Plat does not meet Assessor's Office requirements.

COMMENTS:


" OWNERSHIP DOES NOT APPEAR TO MATCH OUR RECORDS. OUR RECODS INDICATE THE OWNER IS:

EVENCHIK HARVEY B REVOC TR



NOTE: THE ASSESSOR'S CURRENT INVOLVEMENT IN PROCESSING ITS MANUAL MAPS TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. THANK YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED.
05/17/2017 SSHIELD1 H/C SITE REVIEW Approved
05/22/2017 ZELIN CANCHOLA COT NON-DSD TRAFFIC Approved
05/25/2017 LIZA CASTILLO UTILITIES TUCSON ELECTRIC POWER Reqs Change Tucson Electric Power Co., (TEP) has reviewed the Tentative Plat for Camino Modern subdivision submitted on May 8, 2017, and is unable to approve the plat. There is a water conflict with TEP underground primary cable. Please review the TEP Equipment Placement that was provided to Cypress Civil on March 2, 2017, and contact the project Designer, Chuck Leon, to resolve the utility conflict.

Also please correct the name of the resubdivision referenced in the plat title block to “Desert Steppes Estates”.

If you have any questions, please contact me at 520-917-8744.

Thank you,

Mary Burke
Right of Way Agent III
Tucson Electric Power Co.
Mail Stop HQE613
PO Box 711, Tucson, AZ 85702
Office - 520-917-8744
Cell - 520-401-9895
mburke@tep.com
05/26/2017 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Reqs Change Verify the need for a backwater valve for lot 2. Backwater valves shall only be installed where the floor elevation is less than 12" above the rim elevation of the next upstream manhole. Reference: Section 715.1, IPC 2012, as amended by the City of Tucson.
06/01/2017 JOE LINVILLE LANDSCAPE REVIEW Approved
06/07/2017 ALEXANDRA HINES DESIGN PROFESSIONAL REVIEW Approv-Cond DATE: May 30, 2017

FROM: Scott Neeley, AIA
City of Tucson On-Call Design Professional

TO: Alexandra Hines, AICP
Planning & Development Services Department (PDSD)

RE: Design Professional review comments per UDC Section 8.7.3 M for Flexible Lot Development Review of: 450 S Camino Seco
DP17-0024

2nd Review
The review is based upon Unified Development Code (UDC) Sections:
UDC Section 8.7.3.M.1: Architectural Variation

The following review comments are provided to detail the changes required on the plans and documents submitted to PDSD prior to the Design Professional recommending approval of this project.

Comments:

1. Does not comply with UDC Section 8.7.3.M.1: Architectural Variation

Flexible Lot Development (FLD) provides greater flexibility and creativity in residential development but includes some explicit requirements. This project does not meet those requirements. Specifically, it does not comply with UDC Section 8.7.3.M.1: Architectural Variation.

UDC 8.7.M.1.c.3 states: "Garage Placement. For FLD projects with 20 or more single-family detached residential units, no more than 50% of detached residential units throughout the FLD shall be designed with garages that protrude from or are flush with the front wall of the living area or front porch of the house."

Non-compliance with this requirement was noted in the first review of this project. Applicant did not make changes to address this issue; applicant's response is that they consider the front wall of the house to be the wall facing a pedestrian alley, not the wall facing the street of the subdivision. (UDC 11.4.8 defines "Frontage" as "The length of a lot line that abuts a street right-of-way.")

The dominant element in the site plan is vehicular streets, not pedestrian paths. The streets are lined with garages. The result is a conventional garage-loaded street, albeit without pedestrian doors. Pedestrian paths are significantly narrower and are secondary.

The applicant's statement cites "new urbanism development standards to create a more pedestrian-friendly environment" yet the project fails to accomplish what NewUrbanism.org lists as the #1 principle of New Urbanism: "walkability". This includes "pedestrian friendly street design" - "buildings close to street; on street parking; narrow, slow speed streets."

The intention of new urbanism is to foster strong neighborhoods and a sense of community. This is facilitated by site plans that encourage interaction among neighbors and "eyes on the street." The proposed FLD, with garage-loaded primary streets, is not consistent with these intentions.

The dominance of garages also exacerbates the lack of a neighborhood focus or center. The houses on the perimeter have garages oriented towards the middle of the development, their pedestrian entrances pointing away from the other houses, further reducing the possibilities for interaction within the subdivision.
06/07/2017 ALEXANDRA HINES ZONING-DECISION LETTER REVIEW Reqs Change This review has been completed and resubmittal is required. Please resubmit the following items:
1) Two rolled sets of the plans
2) All approved documents submitted previously
3) A disk containing all items submitted
4) All items requested by review staff
5) All items needed to approve these plans
06/07/2017 ALEXANDRA HINES DESIGN PROFESSIONAL REVIEW Approv-Cond PDSD Director approves the proposed Architectural Variation Plan submitted 5/4/2017 in regards to UDC Section 8.7.3.M Design Criteria with the following condition: provide some color perspectives of the garages and the street. Based on those visuals, more architectural variation may be required.

Final Status

Task End Date Reviewer's Name Type of Review Description
09/21/2017 QJONES1 APPROVAL SHELF Completed
09/21/2017 QJONES1 OUT TO CUSTOMER Completed
09/21/2017 QJONES1 REJECT SHELF Completed