Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: DP17-0010
Parcel: 114469380

Review Status: Completed

Review Details: RESUB - SITE and/or GRADING

Permit Number - DP17-0010
Review Name: RESUB - SITE and/or GRADING
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/22/2017 DAVID RIVERA ZONING REVIEW Approved
02/22/2017 DAVID RIVERA HC SITE REVIEW Approved
03/09/2017 PAUL BAUGHMAN ENGINEERING REVIEW Approved DATE: March 10, 2017
DUE DATE: March 15, 2017
SUBJECT: Neighborhood Health Site
TO: Mike Baker, PE
LOCATION: 7285 E Tanque Verde Road
REVIEWERS: Paul Baughman, PE, CFM
ACTIVITY: DP17-0010
SUMMARY: Engineering Division of Planning and Development Services Department has received and reviewed the 2nd submittal of the proposed Development Plan Package. Changes in curb location to accommodate a new TEP transformer at the northwest corner of the site have resulted in new comments. The following items need to be addressed:
1) Per AM 2-06.4.9T show vehicle maneuverability to permit solid waste and any fire trucks that may use the ambulance drop off are.
2) Per UDC 7.4.6E1a a minimum unobstructed radius of 18 feet is required where an access lane or PAAL designated as a fire lane or is used to access refuse and/or recycling collection or loading zones intersects another access lane or PAAL. Please show the required minimum 18 feet curb radius at the northeast corner of the new curb as shown on this second submittal. - emailed turning radius exhibit that shows wider PAALs are sufficient for vehicle movement per code requirements.
3) Please provide updated cut and fill quantities that reflect the changes proposed as part of the 2nd submittal with your response letter to allow for updating of fees in accordance with AM 4-01.5.5C. - aplicant said to double the last number created.
If you have any comments questions or wish to discuss new information, please call or email me at 520-837-5007 or paul.baughman@tucsonaz.gov.
03/14/2017 MARTIN BROWN FIRE REVIEW Approved
03/15/2017 JOE LINVILLE LANDSCAPE REVIEW Approved