Permit Number: DP16-0225
Parcel: 110113620

Address:
4811 E GRANT RD

Review Status: Completed

Review Details: DEV PKG

Permit Number - DP16-0225
Review Name: DEV PKG
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/06/2017 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Completed
01/09/2017 KLEE1 ZONING-DECISION LETTER REVIEW Reqs Change This review has been completed and resubmittal is required. Please resubmit the following items:

1) Two rolled sets of the plans
2) All approved documents submitted previously
3) A disk containing all items submitted
4) All items requested by review staff
5) All items needed to approve these plans
12/08/2016 AHINES2 UTILITIES SOUTHWEST GAS Passed Agency does not need to respond. Notified for informational purposes only.
12/08/2016 ARUIZ1 START PLANS SUBMITTED Completed
12/08/2016 AHINES2 OTHER AGENCIES PIMA ASSN OF GOVTS Passed Agency does not need to respond. Notified for informational purposes only.
12/08/2016 AHINES2 OTHER AGENCIES U. S. POST OFFICE Passed Agency does not need to respond. Notified for informational purposes only.
12/14/2016 MARTIN BROWN COT NON-DSD FIRE Approved
12/20/2016 STEVE SHIELDS ZONING REVIEW Reqs Change CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Steve Shields
Principal Planner

PROJECT: Crossroads Festival Lot 2
Development Package (1st Review)
DP16-0225

TRANSMITTAL DATE: December 21, 2016

DUE DATE: January 6, 2017

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is December 6, 2017.

CONTENT REQUIREMENTS

1. 2-06.4.3 - Provide the development package case number, DP16-0225, adjacent to the title block on all sheets.

1. 2-06.4.3 - Provide rezoning case number, C9-79-68, adjacent to the title block on all sheets.

2-06.4.8 - Existing Site Conditions The following information shall be provided on the plan/plat drawing to indicate the existing conditions on site and within 50 feet of the site. On sites bounded by a street with a width of 50 feet or greater, the existing conditions across the street will be provided.

2. 2-06.4.8.B - It appears that there is an existing electrical easement under the proposed addition that will need to be abandoned prior to approval of the development package. Clearly show the easement and the abandonment recordation information on the plan.

2-06.4.9 - Information on Proposed Development
The following information on the proposed project shall be shown on the drawing or added as notes.

3. 2-06.4.9.F - The C-1 zoning shown on sheet 3 is not correct.

4. 2-06.4.9.H.5.d - It appears that the short term bicycle parking calculation may not be correct. Based on development package, DP14-0068 there are ten (10) racks, equal to 20 spaces, shown east of the theater in a landscape area that have been eliminated. At least 12 of the spaces were required on development package, D06-0012. The required number D06-0012 will need to be replaced somewhere near the Women's Health building.

5. 2-06.4.9.H.5.d - Per DP14-0068 the existing bicycle parking for the entire shopping center was approved by the COT Bicycle Coordinator as is on site. That said the proposed expansion does not exceed the 25% expansion therefore short and long term bicycle parking meeting the requirements of UDC Articles 7.4.9.B, .C, & .D is required for the expansion only. Show the required short and long term bicycle parking on the plan and provide a detail for both or demonstrate on the plan that all existing short & long term bicycle parking meets the requirements of UDC Articles 7.4.9.B, .C, & .D .

6. 2-06.4.9.R - There are striped areas shown near the existing loading space east of the existing theater that go nowhere. This striped area needs to be removed from the site.

7. 2-06.4.9.R - Per TSM 7-01.4.3.A All sidewalks must be a minimum of four feet wide and installed to avoid any obstruction which decreases the minimum width to less than four feet. That said there is a provided sidewalk shown near the southwest corner of the proposed expansion that does not meet the minimum 4' width, 3.67'. Either this sidewalk needs to meet minimum width or a Technical Standards Modification Request (TSMR) will need to be applied for and approved. If you elect to use the TSMR provide the TSMR case number adjacent to the title block on all sheets of the DP and provide a general note stating the TSMR case number, date of approval, what was modified, and if applicable any conditions of approval.

If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
12/20/2016 ZELIN CANCHOLA COT NON-DSD TRAFFIC Approved
12/21/2016 SSHIELD1 ZONING HC REVIEW Approved
12/27/2016 LIZA CASTILLO UTILITIES TUCSON ELECTRIC POWER Approv-Cond Comments are informational only. TEP facilities map in SIRE


4350 E. Irvington Road, Tucson, AZ 85714
Post Office Box 711, Tucson, AZ 85702

December 19, 2016


WR# 6174818

DSD_CDRC@tucsonaz.gov
lisa@metroted.com
kmhall@cypresscivil.com

Dear Mr. Hall

SUBJECT: 4857 E Grant Rd


Tucson Electric Power Company has reviewed and approved the development plan. It appears there are TEP facilities that are in conflict with existincg facilities and will need to be relocated.

It appears 3Ø underground primary is in conflict from FEST-5 to FEST-6 and will need to be relocated Any relocation cost will be billable to the customer.

Enclosed is a copy of a TEP facilities map showing the approximate location of the existing facilities. Any relocation costs will be billable to the customer.

In order to apply for electric service, call the New Construction Department at (520) 918-8300. Submit a final set of plans including approved site, electrical load, paving off-site improvements and irrigation plans, if available include a CD with the AutoCAD version of the plans.

If easements are required, they will be secured by separate instrument. Your final plans should be sent to:
Tucson Electric Power Company
Attn: Rich Harrington
New Business Project Manager
P. O. Box 711 (DB-101)
Tucson, AZ 85702
520-917-8726

Should you have any technical questions, please call the area Designer, Chris Charter @ 520-918-8267.

Sincerely,
Beth Shelton
Elizabeth "Beth" Shelton
Admin Assistant
Design
12/29/2016 ANDREW CONNOR LANDSCAPE REVIEW Reqs Change UNIFIED DEVELOPMENT CODE
4.1 Identification and Descriptive Data
A. All improvements and site information, such as adjacent rights-of-way and property lines, shown on the landscape plan will be identical in size and location to those shown on the base plan (site plan or tentative plat). Should amendments be required to the base plan through the review process, the same amendments will be made to the landscape plan which will then be resubmitted along with the base plan.
B. The landscape plan will contain the following identification in the lower right corner of each sheet:
1. Legal description and address of site;
2. Cross-reference to:
a. Rezoning case;
b. Subdivision case;
c. Board of Adjustment case;
d. Design Development Option case;
e. Development Review Board (DRB) case; and/or,
f. Any other relevant case number for reviews or modifications that affect the site.
7.6. LANDSCAPING AND SCREENING
Canopy Trees in Vehicular Use Areas
a. General Standards
Within a vehicular use area, one canopy tree is required for each four motor vehicle parking spaces or fraction thereof.
(1) The canopy trees must be evenly distributed throughout the vehicular use area. Every parking space must be located within 40 feet of the trunk of a canopy tree (as measured from the center of the tree trunk). Verify if new vehicle use area meets canopy tree requirement.

Ensure that all zoning and Engineering comments and concerns are addressed.
Additional comments may apply.
12/29/2016 LOREN MAKUS ENGINEERING REVIEW Reqs Change 1. Near the east end of the proposed new parking lot there are three existing accessible spaces. The spaces don't have an accessible connection to the sidewalk adjacent to the office building nearby. Either provide an accessible connection or show that these spaces aren't required for the nearest building and convert the spaces to regular parking.
2. Provide curb openings to direct stormwater runoff to the proposed landscape/water harvesting areas.

Final Status

Task End Date Reviewer's Name Type of Review Description
01/18/2017 LBOJORQ1 REJECT SHELF Completed
01/09/2017 KLEE1 APPROVAL SHELF Completed
01/09/2017 KLEE1 OUT TO CUSTOMER Completed