Permit Review Detail
Review Status: Completed
Review Details: REVISION - TENT PLAT & CORE RESUB
Permit Number - DP16-0221
Review Name: REVISION - TENT PLAT & CORE RESUB
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/26/2017 | ALEXANDRA HINES | START | PLANS SUBMITTED | Completed | |
| 11/22/2017 | ALEXANDRA HINES | DESIGN PROFESSIONAL | REVIEW | Reqs Change | DATE: 20 November 2017 FROM: Richard Fe Tom, AIA, City of Tucson On-Call Design Professional TO: Kelly Lee, Planning and Development Services Department RE: Design Professional review comments for Flexible Lot Development Review DP16-0220 and DP16-0221 Mountain Vail Reserve per Design Criteria of UDC Section 8.7.3 M The following review comments are provided to detail the changes required on the plans and documents submitted to PDSD prior to the Design professional recommending approval of this project. The review is based upon our review of electronic copies of Development Packages DP16-0220 and DP16-0221 and paper copies of the Architectural Variation Plan (AVP) and Privacy Mitigation Plan (PMP) for Mountain Vail, Part B and Part 1 for compliance with Unified Development Code (UDC) Section 8.7.3 M: Design Criteria Design Criteria 1. Architectural Variation Approve. An Architectural Variation Plan (AVP) demonstrating compliance with the requirements of UDC Section 8.7.3.M.1.d.1 has been prepared in accordance with UDC Section 2-06.5.3.E. 2. Transition Edge Treatment and Mitigation for Adjacent Properties b.(3) A Privacy Mitigation Plan (PMP) has been prepared in accordance with UDC Section 2-06.5.3.F but the plan does not adequately demonstrate compliance with UDC Section 8.7.3.M.2.b "solar access" as noted in Design Criteria Comment #3.a below. 3. Solar Access and Passive Solar a. Indicate in the PMP that per the Uniform Development Code (UDC), Section 7.3.1, the use of solar energy collectors as part of a principal structure or as an accessory structure is permitted. Indicate how 2-story structures adjacent to Lots with 1-story structures have been oriented to mitigate or minimize the effect of shadows cast by the 2-story structure onto adjacent properties in accordance with Section 7.3.2 "Shadows cast from Multistory Structures." 4. Alternative Compliance. No Comment. No Alternative Compliance requests were submitted for consideration. End of Review |
| 11/22/2017 | ALEXANDRA HINES | ZONING-DECISION LETTER | REVIEW | Reqs Change | This review has been completed and resubmittal is required. Please resubmit the following items: 1) Two sets of the plans 2) All approved documents submitted previously 3) A disk containing all items submitted 4) All items requested by review staff 5) All items needed to approve these plans |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 11/27/2017 | ARUIZ1 | OUT TO CUSTOMER | Completed |