Permit Number: DP16-0219
Parcel: 140411150

Address:
3320 E ELVIRA RD

Review Status: Completed

Review Details: SITE and/or GRADING

Permit Number - DP16-0219
Review Name: SITE and/or GRADING
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
12/13/2016 DAVID RIVERA ZONING REVIEW Reqs Change CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: David Rivera for Steve Shields - Principal Planner
PDSD Zoning Review Section

PROJECT: Thermo King Tucson Expansion - 3320 E Elvira Road
Development Package (1st Review)
DP16-0219

TRANSMITTAL DATE: December 13, 2016
DUE DATE: December 28, 2016

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is November 29, 2017.

SECTION 2-06.0.0: DEVELOPMENT PACKAGE (TENTATIVE PLATS AND SITE PLANS)
Section


2-06.4.3 - The administrative street address and relevant case numbers (development package document, subdivision, rezoning, board of adjustment, DDO, MDR, DSMR, overlay, etc.) shall be provided adjacent to the title block on each sheet.

1. COMMENT: Provide the development package case number, DP16-0219, adjacent to the title block on each sheet.


2-06.4.7.A.6.a - List additional applications and overlays, by case number (if applicable), in lower right corner of each sheet. As a general note provide the type of application processed or overlays applicable, a statement that the project meets the criteria/conditions of the additional application or overlay, the case number, date of approval, what was approved, and the conditions of approval, if any.

2. COMMENT: The applicant/Owner is requesting approval of an IPP. Your request has been made to Glenn Moyer; unfortunately Glenn is no longer working for PDSD. The IPP plan must be submitted to Mark Castro who is currently the person assigned to review IPP requests. Mark can be reached at 837-4979 or by email at mark.castro@tucsonaz.gov . Mark will assign a case number to the IPP plan. The IPP plan case number must be listed next to the title block of all DP plan sheets. List the date of approval and if applicable any conditions related to the approval.

2-06.4.7.A.8.c - Percentage of building, lot area, or vehicular use area expansion. If the building(s) or lot area have been previously expanded, those calculations shall be included; and,

3. COMMENT: The previously approved DP included two parcels that had been combined into one lot. This DP includes a third lot. Include a lot area expansion under general note 17. Also, zoning is requesting that a Pima County Tax Parcel Combo be processed prior to approval of the DP. If the combo has already been processed provide copies of the Pima County Assessor's combo form signed by the Pima County Assessor's Office.


2-06.4.9.H.5.a - Show all motor vehicle off-street parking spaces provided, fully dimensioned. As a note, provide calculations on the number of spaces required (include the ratio used) and the number provided, including the number of spaces required and provided for the physically disabled. The drawing should indicate parking space locations for the physically disabled. A typical parking space detail shall be provided for both standard parking spaces and those for the physically disabled. For information on parking requirements for the physically disabled, refer to adopted building and accessibility codes of the City of Tucson. Design criteria for parking spaces and access are located in Section 7.4.6, Motor Vehicle Use Area Design Criteria, of the UDC.

4. COMMENT: This comment will remain until the IPP application process is completed and approved.


2-06.4.9.M - Grading Plan

2-06.4.9.M.1 - A conceptual grading plan is required on projects with significant topographic conditions. The PDSD Engineering Administrator or designee will determine the need for such a plan.
2-06.4.9.M.2 - Concurrent Review. For all projects, grading plans may be included in the development package and will be reviewed concurrently.

5. COMMENT: Once zoning approved the DP site plan the grading plan is also approved by zoning as it relates to the zoning review purview.


2-06.4.9.X - Show compliance with landscaping and screening requirements by locations, material descriptions, and dimensions. Specific plant or hardscape material shall be detailed on a landscape plan. A detailed landscape plan is required. In accordance with Section 2-11.0.0, Landscape Plan Requirements.

6. COMMENT: Review the Landscape Reviewer's comments related to landscape borders and screening.



If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
12/14/2016 DRIVERA1 ADA REVIEW Passed
12/14/2016 DAVID RIVERA H/C SITE REVIEW Approved
12/15/2016 PAUL BAUGHMAN ENGINEERING REVIEW Reqs Change DATE: December 15, 2016
DUE DATE: December 28, 2016
SUBJECT: Thermo King Tucson Expansion
TO: Kevin Hall, PE
LOCATION: 3320 E Elvira Road
REVIEWERS: Paul Baughman, PE, CFM
ACTIVITY: DP16-0219
SUMMARY: Engineering Division of Planning and Development Services Department has received and reviewed the proposed Development Plan Package. The following items need to be addressed:
1) Per AM 2-06.4.3 please add the case number (DP16-0219).
2) Per UDC 7.14.4, Section 14.2, item 1, retention requirements apply to any commercial or industrial development if the site or lot is larger than one standard acre. Since the overall development site is larger than an acre, 5-year retention is required. Please update the plan and drainage report accordingly. Please show calculation per UDC 7.14.3, Section 3.2.1 (equation 3.3) Infiltration rates for the required 12 hour drain down time will need to comply with UDC 7.14.3, Section 3.5.1, Item 3a.
3) Per UDC 7.4.6I and the 3rd paragraph of the November 28, 2016 Individual Parking Plan letter to Glenn Moyer, the vehicle use area for which keynote 19 is called out on sheet 2 does not qualify for the vehicle storage exemption. Please update detail A/4 to comply with the surfacing requirements of UDC 7.4.6I (a, b or c). The Google Street View Picture shows actual use of this area.

4) Keynote 5 and keynote 7 are both called out west of the south half of the existing building. This appears to be a conflict. Please update accordingly.
5) Keynote 23 is calling for an existing non compliant condition to remain. See the Google Street View. Please make appropriate adjustments.
If you have any comments questions or wish to discuss new information, please call or email me at 520-837-5007 or paul.baughman@tucsonaz.gov.
12/21/2016 MARTIN BROWN FIRE REVIEW Approved
12/27/2016 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Reqs Change Revise the site utility drawing to include the location, invert and rim elevations of the upstream and downstream sanitary sewer manholes along with the Pima County Wastewater Management Department (PCWMD) reference number. If the rim elevation of the next upstream sanitary manhole is higher than the first floor elevation or is less than 12" below the first floor elevation, provide a note on the plans requiring the installation of a backwater valve when future plumbing activities take place. Reference: City of Tucson Administrative Manual, Section 2-06.4.8D; Section 715.1, IPC 2012, as amended by the City of Tucson; and Section 107.2.1, IBC 2012.
12/29/2016 JOE LINVILLE LANDSCAPE REVIEW Reqs Change UNIFIED DEVELOPMENT CODE
4.1 Identification and Descriptive Data
A. All improvements and site information, such as adjacent rights-of-way and property lines, shown on the landscape plan will be identical in size and location to those shown on the base plan (site plan or tentative plat). Should amendments be required to the base plan through the review process, the same amendments will be made to the landscape plan which will then be resubmitted along with the base plan.
Ensure that all zoning and Engineering comments and concerns are addressed.
Additional comments may apply.
12/29/2016 JOE LINVILLE NPPO REVIEW Approved