Permit Review Detail
Review Status: Completed
Review Details: REVISION - - 1ST
Permit Number - DP16-0204
Review Name: REVISION - - 1ST
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/07/2020 | ANDREW CONNOR | LANDSCAPE | REVIEW | Reqs Change | Landscape and Screening requirements. 7.6.2. APPLICABILITY The provisions of this section apply to the following: A. All new development; and, B. Expansion of existing development, as provided below: 1. Buildings Greater Than 10,000 Square Feet On sites where the gross floor area of the existing building(s) is more than 10,000 square feet, expansion in square footage of land area, floor area, lot coverage, or vehicular use area as follows: a. If the expansion is less than 25%, the standards of this section apply only to the proposed expansion. Existing development on the site is subject to the zoning standards in effect at the time the existing development received zoning approval. b. If the expansion is 25% or greater or if expansions as of February 15, 1991, cumulatively result in a 25% or greater expansion in land area, floor area, lot coverage, or vehicular use area, the standards of this section apply to the entire site. Provide expansion calculations. Ensure that all Zoning and Engineering comments and concerns are addressed prior to landscape approval. |
| 01/09/2020 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: David Rivera PDSD Zoning Review Section PROJECT: Med Mar Green House Expansion - Retail Use Group - Med. Marijuana / DOSCL) Development Package (1st Review) - 265 E. Missouri Street DP16-0204 - I-1 Zoning TRANSMITTAL DATE: January 9, 2020 DUE DATE: January 9, 2020 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is December 10, 2020. CONTENT REQUIREMENTS 2-06.4.2 - The title block shall include the following information and be provided on each sheet: 2-06.4.2.D - The page number and the total number of pages in the package (i.e., sheet xx of xx). 1. COMMENT: 2-06.4.2.D - Label the sheet number on sheet four. 2-06.4.7.A.8 - For development package documents provide: 2-06.4.7.A.8.c - Percentage of building, lot area, or vehicular use area expansion. If the building(s) or lot area have been previously expanded, those calculations shall be included; and, 2. COMMENT: 2-06.4.7.A.8.c - Include a building (percentage) expansion calculation. Per the previous approved DP the green house SF was 16,632. This revision proposes a total of 18,000 SF of Green House areas. 2-06.4.8 - Existing Site Conditions The following information shall be provided on the plan/plat drawing to indicate the existing conditions on site and within 50 feet of the site. On sites bounded by a street with a width of 50 feet or greater, the existing conditions across the street will be provided. 3. COMMENT: 2-06.4.8 - Provide the information as noted by the standard above. 2-06.4.9.Q - Provide the square footage and the height of each commercial, industrial, or business structure and the specific use proposed within the footprint of the building(s). 4. COMMENT: 2-06.4.9.Q - Label Grow House number 5 with the Use, square footage and hgt. 5. COMMENT: - Label the wall heights around the perimeter of the site. ***For additional information on the any standard presented in this memo, please refer to the City of Tucson "Unified Development Code" - Administrative Manual Section 2-06 or Technical Standards noted in the comments. https://www.tucsonaz.gov/pdsd/all-codes-plans-determinations If you have any questions about this transmittal, Contact David Rivera on Tuesday, or Wednesday at (520) 837-4957 or by email David.Rivera@tucsonaz.gov or contact Steve Shields any time during the week at (520) 837-4956 or email Steve.Shields@tucsonaz.gov RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package |
| 01/09/2020 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Completed | |
| 01/09/2020 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | PDSD TRANSMITTAL FROM: Steve Shields Section Manager PROJECT: MED MAR Greenhouse Expansion DP16-0204 (Revision) Development Package TRANSMITTAL DATE: January 9, 2020 The development package has been reviewed by the Zoning Review Section for minimal compliance with the Administrative Manual Section 2-06. It has been determined that the submitted plans do not provide sufficient information to complete a plan review. The following items need to be addressed prior to re-submittal. 1. Provide a detailed revision letter that clearly describes what is being changed or modified. 2. As an expansion is proposed a Zoning Compliance Application for Medical Marijuana Locations must be submitted and approved prior to approval of the revision to the development package. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards. If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956 |
| 01/13/2020 | JOHN VAN WINKLE | ENGINEERING | REVIEW | Reqs Change | DP16-0204 1) Please obtain written approval from Pima County Flood Control District for the proposed work in the Rodeo Wash. Pima County Flood Control has a maintenance responsibility easement along this portion of the Rodeo Wash. Contact Ann Moynihan Ann.Moynihan@pima.gov 2) Confirm through infiltration testing, that the storm crate retention draw down time will be less than 12 hrs. Reference COT Stormwater Detention/Retention manual, section 3.5 3) This project proposed disturbance within a 100 year floodplain and also a WASH ordinance Wash. Reference Tucson City Code section 29 article VIII and provide the necessary mitigation/report for the proposed disturbance 4) The proposed plan shows a new structure being placed within the erosion hazard setback of the Rodeo Wash. All proposed structures must be placed outside of the erosion hazard set. Reference Tucson City Code section 26-7 5) Provide invert elevations for the proposed storm drain pipe at all inlet and outlet locations 6) Provide a cross section detail showing pipe bedding 7) Provide updated waste stream calculations based on proposed expansion of grow area. Note that the square footage of the grow areas shown on sheet 1 does not match that which is shown on sheet 2 8) Please update the expiration date on the Engineer Seal John Van Winkle, P.E. John.VanWinkle@tucsonaz.gov 520-837-5007 |
| 01/14/2020 | MARTIN BROWN | FIRE | REVIEW | Approved | |
| 01/15/2020 | SBEASLE1 | ZONING-DECISION LETTER | WRITE DECISION LETTER | Reqs Change | 1st REVISION PLAN RETURNED FOR CORRECTIONS NOTICE - A resubmittal is required Permit/Activity Number: DP16-0204 Project Description: SITE/GRADING - Med Mar Greenhouse. Fees Due: $ 429.00 (see the "Balance" column in image below). Please pay fees before sending in a resubmittal. Pay: (Online payments are not available for this permit number due to it being over two years old) 1. In person at the City Permit Counter (Mon-Fri, 8:00 AM to 2:00 PM) 2. By mail - a check payable to the City of Tucson (address is below), include the Activity Number View the documents and the reviewer's comments on PRO: www.tucsonaz.gov/pro (If information is not available, check back later after data transfers to PRO.) - Home page, left side, Activity Search, enter the Activity Number - Permits section, click on blue tab - Documents section, click on blue icon to the right of each document - Reviews section, click on Review Details After the corrections are made, please name your Revision #1, 2nd submittal documents accordingly, for example: REV-1_2_Plan_Set. YOUR NEXT STEPS: Submit the following items to the Filedrop- https://www.tucsonaz.gov/file-upload-pdsd (In the Project Description field, enter the Activity Number.) 1) Comment Response Letter (your response to the reviewer's Requires changes comments) 2) Plan Set (or individual sheets) 3) Any other items requested by review staff Thank you. Sharon Beasley, Permit Specialist City of Tucson Planning and Development Services Attn: Permit Counter/Payments 201 N. Stone Avenue, 3rd Floor Tucson, AZ 85701 email: COTDSDPermits@TucsonAz.gov |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 01/15/2020 | SBEASLE1 | OUT TO CUSTOMER | Completed |