Permit Review Detail
Review Status: Completed
Review Details: SITE and/or GRADING
Permit Number - DP16-0198
Review Name: SITE and/or GRADING
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/15/2016 | KEN BROUILLETTE | FIRE | REVIEW | Approved | |
| 11/25/2016 | PAUL BAUGHMAN | ENGINEERING | REVIEW | Approved | |
| 12/02/2016 | SSHIELD1 | ADA | REVIEW | Passed | |
| 12/02/2016 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Steve Shields Principal Planner PROJECT: Realty Executives - Expansion Development Package (1st Review) DP16-0198 TRANSMITTAL DATE: December 2, 2016 DUE DATE: December12, 2016 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM). Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is November 09, 2017. CONTENT REQUIREMENTS 1. 2-06.4.3 - Provide the development package case number, DP16-0198, adjacent to the title block on all sheets. 2-06.4.7 - General Notes The following general notes are required. Additional notes specific to each plan are required where applicable. 2-06.4.7.A - Zoning and Land Use Notes 2. 2-06.4.7.A.4 - Zoning & Land Use Note 3 provide the Use Specific Standards for a Administrative and Professional Office in the C-2 zone; see UDC Table 4.8-4. 2-06.4.9 - Information on Proposed Development The following information on the proposed project shall be shown on the drawing or added as notes. 3. 2-06.4.9.H.5.d - Clearly demonstrate on the plan that the short term bicycle parking meets the requirements of UDC Article 7.4.9.C.2.a. The detail does not show any public entrances. 4. 2-06.4.9.H.5.d - Demonstrate how the requirements of UDC Articles 7.4.9.B.1.e & 7.4.9.B.2.a are met. 5. 2-06.4.9.R - Per TSM 7.01.4.2.A Sidewalks associated with PAALs must be physically separated from any vehicular travel lane by means of curbing, grade separation (minimum six inches), barriers, railings, or other means, except at designated crosswalks. That said it is not clear if the new sidewalk, called out under keynote 10, near the southeast corner of the proposed expansion highlighted in orange, is physically separated from the PAAL. Also clarify if the sidewalk, highlighted in blue, is a ramp or flush with pavement. Once the above comments are addressed Zoning will provide and over-the-counter review. If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package, & Approved Pima County Combo Request form. |
| 12/02/2016 | SSHIELD1 | H/C SITE | REVIEW | Reqs Change | See Zoning comments |
| 12/07/2016 | JOE LINVILLE | LANDSCAPE | REVIEW | Approved | |
| 12/07/2016 | JOE LINVILLE | NPPO | REVIEW | Approved | |
| 12/12/2016 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Reqs Change | Revise the site drawing to include the following information: a. The location of sanitary sewers including the pipe diameter and the invert and rim elevations of all manholes; along with the Pima County Wastewater Management Department (PCWMD) reference number. b. The points of connection to existing public sewers. Reference: City of Tucson Administrative Manual No. 2-06.0.0, Section 4.8 and Section 107.2.13, IBC 2012. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 12/13/2016 | ARUIZ1 | OUT TO CUSTOMER | Completed |