Permit Review Detail
Review Status: Completed
Review Details: TENTATIVE PLAT REVIEW
Permit Number - DP16-0176
Review Name: TENTATIVE PLAT REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/28/2017 | MMENDIB1 | START | PLANS SUBMITTED | Completed | |
| 03/08/2017 | DAVID RIVERA | H/C SITE | REVIEW | Reqs Change | See Zoning Comments. |
| 03/08/2017 | KLEE1 | PIMA COUNTY | ADDRESSING | Approv-Cond | DP16-0176_6th & Medina Tentative Plat/2nd Submittal is being Returned for Corrections by Pima County Addressing. There are two minor corrections requested in the attached pdf. Please note that the attached pdf was provided to me by the applicant on 3/6/17 when I noticed that the 2nd submittal plans and the Comment Response on your website did not include Addressing’s comments. The revision date on this DP16-0176 is 3/3/17. Please let me know if you have any questions. Thank you, Robin Freiman Addressing Official Pima County Development Services Department 201 N Stone AV – 1st Floor Tucson, AZ 85701 (520) 724-7570 |
| 03/08/2017 | DAVID RIVERA | ZONING | REVIEW | Reqs Change | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: David Rivera for Steve Shields - Principal Planner PDSD Zoning Review Section PROJECT: Development Package (2nd Review) DP16-0176 TRANSMITTAL DATE: March 8, 2017 DUE DATE: March 29, 2017 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM). Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is November 1, 2017. 2-06.2.4 Concurrent Reviews The development package is designed to allow for concurrent review of any site related reviews. Concurrent review means that all plans and documents needed for the review are submitted as one package. Examples of site related reviews include but are not limited to: site plans, landscape plans, NPPO plans, water harvesting plans, grading plans, SWPPP plans, floodplain use permits, and overlay reviews. Separate applications are often required for the different site related reviews even if the plans are submitted concurrently; and, 1. Follow Up To Previous Comment 1: A SWPP sheet and 3 grading plan sheets were included in this submittal. Assure that the new sheets are consistent with the DP sheets title block and information within the title block. 2-06.3.4 - A title block shall be provided in the lower right quadrant of each sheet. PREVIOUS COMMENT 1: The title block of all plan sheets should be consistent and contain the same information. Revise the title block of the landscape sheets to match sheets 1-3. 2. Follow Up To Previous Comment 4: As mentioned in comment 1 above, a total of four additional sheets have been included in this submittal of the DP. These sheets have not been accounted for in the sheet index on sheet 1 of 10. Revise the sheet index as required to include the SWPP and grading plan sheets. (Additional Fees will be assessed) 2-06.3.12 - An index of sheets in the development package shall be provided on the first sheet. PREVIOUS COMMENT 4: The sheet index on the cover sheet shall include the number and name of all plan sheets in the package. This DP contains 10 sheets. Revise the sheet index as required. 3. Follow Up To Previous Comment 6: Revise the title block of the new sheets to match the title blocks of the DP sheets. 2-06.4.2 - The title block shall include the following information and be provided on each sheet: 2-06.4.2.A - The proposed name of the project or subdivision, or if there is no name, the proposed tenant's name; PREVIOUS COMMENT 6: As noted in comment one, the title block of all sheets shall be consistent. Revise the title blocks on the landscape and irrigation sheets to match sheets 1 - 3. 4. Follow Up To Previous Comment 7: Revise the sheet numbers in the lower right corner of sheet to include the four new sheets, there are now 14 sheets in the DP. 2-06.4.2.D - The page number and the total number of pages in the package (i.e., sheet xx of xx). PREVIOUS COMMENT 7: The sheet number in the lower right corner of all plan sheets shall be listed, i.e., 1 of 10, 2 of 10, etc. Revise the sheet numbers to correctly list the sheet number and number sheets in the package. 5. Follow Up To Previous Comment 8: Assure that the administrative address is listed next to the title block of all plan sheets. (Only four of the 14 sheets include the administrative address.) 2-06.4.3 - The administrative street address and relevant case numbers (development package document, subdivision, rezoning, board of adjustment, DDO, MDR, DSMR, overlay, etc.) shall be provided adjacent to the title block on each sheet. PREVIOUS COMMENT 8: Provide the development package case number, DP16-0176, adjacent to the title block on each sheet. List the administrative address next to the title block of all plan sheets. 2-06.4.7 - General Notes The following general notes are required. Additional notes specific to each plan are required where applicable. 6. Follow Up To Previous Comment 10: Review UDC Section 5.6 and list the correct UDC section(s) that is/are applicable to this development. The section listed in General note 32 is from the LUC. Remove and replace with the correct UDC sections. 2-06.4.7.A - Zoning and Land Use Notes PREVIOUS COMMENT 10: Revise all zoning notes that reference the LUC. This development is to be developed under the UDC and all code references should be noted as such. 7. Follow Up To Previous Comment 12: List the Use Specific Standards applicable in the R-2 Zone noted in the previous comment. The square footages listed in the calculations for the R-2 and C-1 do not seem to make since or add up correctly. List the square footage based on the following; 1. Overall square footage of the surveyable area for the R-2 and C-1 zones independently, 2. SF of the lots within the R-2 and C-1 Zone areas independently, 3. SF of the streets within the R-2 and C-1 zone areas independently, 4. SF of the NUOS areas within the R-2 and C-1 Zone areas independently, etc. The density calculation for the R-2 And C-1 Zone areas are to be included based on the overall acreage within each zone. The density calculation for the R-2 And C-1 Zone areas are to be included based on the overall acreage within each zone. In the C-1 Zone only the area that is not within the CUZ-2 overlay can be used to calculate the allowed density. The actual coverage and density (See UDC Section 6.4.7.1.a for density calculations) cannot be verified until the above information is provided correctly. (As a side note, after reviewing the TP site sheet 2, it was noted that the scale factor listed next to the north arrow is incorrect. The scale appears to be 1 to 40 and not 1 to 50 as noted on the plan, revise the scale as required.) 2-06.4.7.A.4 - Identify the existing and proposed use of the property as classified per the UDC. List all UDC sections applicable to the proposed uses. PREVIOUS COMMENT 12: General note 33 shall be revised to list the "Use Specific Standards" applicable in R-2: 4.9.7.B.6, .9, & .10. In the UDC the development designator was removed and is no longer applicable. Remove the development designator notes from the R-2 and C-1. Review UDC section 6.3.4 for dimensional standards and revise any calculations as needed utilizing the UDC sections applicable to residential development in the R-2 and C-1 Zones. Include a Site coverage calculation for each area within the R-2 and C-1 Zones; see UDC Section 6.4.3 for information on site coverage. 8. Follow Up To Previous Comment 13: General note 32 was not revised to include the applicable UDC Section number. The old LUC number is still listed, revise the section number to state the correct UDC Section. The cover sheet site plan has been annotated with a CUZ -1 designation, the correct designation is CUZ -2, revise the designation accordingly. Label the 128' height line on the cover sheet and all sheets where the AEZ height lines are noted. 2-06.4.7.A.6 - If a plan or plat is prepared in conjunction with other applications or overlays or the parcel being developed is subject to conditions of an application processed previously, additional information must be added to the plan. Such applications and overlays include, but are not limited to: annexations; re-zonings; special exceptions; Board of Adjustment variances; Design Development Options; Technical Standard Modification Request; overlays (Airport Environs Zone, Environmental Resource Zone, Gateway Corridor Zone, Hillside Development Zone, Historic Preservation Zone, Major Streets and Routes, Rio Nuevo District, Scenic Corridor Zone, WASH); Modification of Development Regulations through the Downtown Area Infill Incentive District or Rio Nuevo District; Downtown Heritage Incentive Zone; or, Design Review Board. Provide the following information on the plan. PREVIOUS COMMENT 13: This development is subject to compliance with the MSR and AEZ requirements under the UDC. List the UDC section number for the MS&R and AEZ in general note 31. The UDC section for the MS&R is section 5.4 and 5.6 for AEZ. Revise general note 31 as required. General note 32 references the LUC sections for the AEZ. Revise general note 32 to reference the applicable UDC and Technical Standards section numbers. 9. Follow Up To Previous Comment 17: See redlines for additional info related to the information requested in the previous comment. 2-06.4.7.A.8 - For development package documents provide: 2-06.4.7.A.8.a - Floor area for each building; 2-06.4.7.A.8.b - Percentage and area in square feet of building and accessory building coverage; 2-06.4.7.A.8.c - Percentage of building, lot area, or vehicular use area expansion. If the building(s) or lot area have been previously expanded, those calculations shall be included; and, PREVIOUS COMMENT 17: For your convenience I have attached a sheet with the development criteria as allowed or required by the current UDC. It appears that information from the previous LUC code has been listed under General note 34 and building setback text block. Revise the development criteria as allowed or required by the UDC. Use the information provided to revise the development criteria accordingly. 10. Follow Up To Previous Comment 18: The previous comment is still applicable until the calculations as noted in the comments above have been correctly addressed. 2-06.4.7.A.8.d - When the proposed site is part of a larger site, the calculations encompass the entire site, whether existing or proposed. If the project is being phased, calculations must show that, at each phase, requirements are being met. PREVIOUS COMMENT 18: Add the information as noted by the standard above. The final tallies for site coverage if included shall take into account the C-1 and R-2 sites as a whole. 11. Follow Up To Previous Comment 25: Zoning has reviewed the included Grading Plan and compared it to the DP Site Sheet as it pertains to the zoning review purview. Once the DP is approved the grading Plan is also approved. Assure that any changes made to the DP site sheet that impacts design are also made to all site sheets including the grading plan sheets. 2-06.4.9.M - Grading Plan 2-06.4.9.M.1 - A conceptual grading plan is required on projects with significant topographic conditions. The PDSD Engineering Administrator or designee will determine the need for such a plan. PREVIOUS COMMENT 25: A grading and SWPP plan was not included in the Development Package and unless the applicant wishes to submit a grading and SWPP plan with the next DP submittal the grading plan will be reviewed under a separate grading permit application. If a grading and SWPP plan is submitted with the DP on the next submittal, a memo must accompany the package and the permit counter staff must be made aware that a grading plan has been added to the package which also requires additional review fees. 12. Follow Up To Previous Comment 27: Zoning could not verify that the information requested in the previous comment was added to the DP site sheet. Address as requested per the previous comment. 2-06.4.9.O - All applicable building setback lines, such as erosion hazard, floodplain detention/retention basins, and zoning, including sight visibility triangles, will be shown. PREVIOUS COMMENT 27: Draw and label the street and interior perimeter building setbacks on plan sheet two. Dimensioned lot details that identify the building footprint and building setback requirements may also be included to demonstrate how the building setbacks from the MS&R, interior streets, interior perimeter setbacks and boundary setbacks will be met. The largest model floor plan may be used as reference. 13. Follow Up To Previous Comment 13 and 29: The requested horizontal slopes for the pedestrian circulation could not be verified on the site or grading plan sheets. Label the sidewalk cross slopes on the interior street cross section. 2-06.4.9.R - Show on-site pedestrian circulation and refuge utilizing location and the design criteria in Section 7-01.0.0, Pedestrian Access, of the Technical Standards Manual. PREVIOUS COMMENT 28: Demonstrate on the plan that the accessible route requirements for street sidewalks have been accomplished. The cross and horizontal slopes shall be noted on the plan. 2-06.4.9.S - Show existing or proposed pedestrian circulation along abutting rights-of-way. Such sidewalks must comply with accessibility requirements for the physically disabled and the design criteria in Section 10-01.0.0, Street Technical Standards, of the Technical Standards Manual. PREVIOUS COMMENT 29: Same as comment 27. 14. Follow Up To Previous Comment 32: The response to the previous comment was insufficient. Either provide copies of the CC&R's are respond accordingly as to whether CC&R's will be provided at Final Plat review. 2-06.5.3.G - Covenants, Conditions, and Restrictions 2-06.5.3.G.1 - Provide three copies of the Covenants, Conditions, and Restrictions (CC&Rs) regarding the homeowner's association's responsibility for the ownership and maintenance of commonly-owned property. 2-06.5.3.G.2 - Provide two copies of the protective covenants or common use agreements for any shared areas being established by easements over individually-owned property. PREVIOUS COMMENT 32: While this subdivision will not be developed under the FLD overlay there are common areas proposed that must be maintained by the owners or a homeowner's association. If available, provide two copies of the proposed CC&R's for this subdivision on the next submittal or if they are not available the CC&R's must be submitted with the final plat for review. 15. Follow Up To Previous Comment 33: Review all sheets for redlines and address as required. PREVIOUS COMMENT 33: Review all redlines on sheets 1-3 and for additional items that must be revised or removed. 16. General note 27 does not appear to be accurate as noted. Lot 10 as drawn is not within the CUZ-2 delineated area of the TIA. Remove general note 27 or revise the note to clearly state any restriction to be placed on lot 10. 17. Add a general note stating that all dwellings will be built to comply with the requirements of Inclusive Home Design Ordinance. If you have any questions about this transmittal, Contact David Rivera on Tuesday or Wednesday at (520) 837-4957 or by email David.Rivera@tucsonaz.gov or contact Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package |
| 03/09/2017 | ED ABRIGO | PIMA COUNTY | ASSESSOR | Approved | Office of the Pima County Assessor 115 N. Church Ave. Tucson, Arizona 85701 BILL STAPLES ASSESSOR TO: CDRC Office Subdivision Review City of Tucson (FAX# 791-5559) FROM: Ada Griffin GIS Cartographer Pima County Assessor's Office DATE: March 9, 2017 RE: Assessor's Review and Comments Regarding: DP16-0176 6th & Medina Tentative Plat/2nd Submittal _ * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * X Plat meets Assessor's Office requirements. _______ Plat does not meet Assessor's Office requirements. COMMENTS: THANK YOU FOR YOUR SUBMITTAL NOTE: THE ASSESSOR'S CURRENT INVOLVEMENT IN PROCESSING ITS MANUAL MAPS TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. THANK YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED. |
| 03/16/2017 | KLEE1 | OTHER AGENCIES | TUCSON AIRPORT AUTHORITY | Approv-Cond | March 14, 2017 Dear Ms. Lee, Thank you for the opportunity to comment on DP16-0176, 6th and Medina; 1st Submittal, a development package application of a tentative plat for an approximately 8.96 acre site located on the northeast corner of South 6th Avenue and East Medina Road. The proposed land use is residential. The Tucson Airport Authority acknowledges that the development of a residential use is allowed on this project site since it is currently zoned as Medium Density Residential (R-2) and is in compliance with the City of Tucson's Compatible Use Zone 2 (CUZ-2) overlay. The Tucson Airport Authority objects to this project since it is a new residential use in the immediate vicinity of the Tucson International Airport that will have residents who will be impacted by future aircraft operations and noise. In addition, the proposed residential use is inconsistent with the City of Tucson 12th Avenue - Valencia Road Area Plan. This project site is located within the City of Tucson 12th Avenue - Valencia Road Area Plan, Subarea 6. Subarea 6 identifies that a majority of the area is within a high noise exposure area and places a heavy emphasis on the development of an employment center with park industrial, office, and/or commercial uses. Subarea 6 does not support residential uses for this property. From a planning perspective, and as clearly reflected in the City of Tucson's own planning documents, the employment center, park industrial, office, and commercial uses would better support the surrounding community with additional employment options, and are far more compatible uses to the airport and its environs. As you know, residential development, particularly like the one proposed near the end of current and future runways has the potential to have a direct negative impact to the residents who choose to live there, and will create an ongoing noise compatibility issue for both the City of Tucson and the Tucson International Airport. We recommend that the City of Tucson, to the extent permitted by law, and consistent with its own code and planning for the airport environs, require the developer to install noise mitigation for all residential units (sound insulation, triple pane windows, etc.) to limit the impact of noise and aircraft operations for future residents and require and ensure that the recommended Avigation Easement is recorded for this plat. If this project proceeds, TAA recommends the following conditions should be added to any approval associated with this project and placed in the general notes of the approved development plan. Condition of approval: "That prior to the City's approval of any construction permit for a permanent building, the property owner shall record the Avigation Easement prior to the subdivision process which discloses the existence, and operational characteristics of the Tucson International Airport to future owners or tenants of the property and further conveys the right to the public to lawfully use the airspace above the property. A copy of the recorded Avigation Easement shall be provided to the Tucson Airport Authority. The City of Tucson shall verify that the Tucson Airport Authority has received a recorded Avigation Easement before issuing the approval of any construction permits for a permanent building. The content of such documents shall be according to the form and instructions provided. That development shall not cause or potentially affect aviation in the vicinity of the site, including but not limited to, physical obstructions to aircraft operations, interference with operations by way of electrical static, visual obstructions through emissions or glare, and/or the open storage of petroleum products, explosive materials, or materials which attract or lead to the concentration of wildlife." The current property owner or person authorized to sign on behalf of the current property owner shall complete, sign, and record the Avigation Easement. The Avigation Easement shall be recorded with the Pima County Recorder's Office. Once the Avigation Easement is recorded please send a copy of the recorded easement to Tucson Airport Authority by either email (send to srobidoux@flytucson.com) or to the mailing address provided below. Scott Robidoux Airport Planner Tucson Airport Authority 7250 South Tucson Boulevard Suite 300 Tucson, AZ 85756 The developer shall provide the Airport Disclosure Statement form, at time of sale, to the new property owners with new unit purchases. In the event this proposed project does not involve the sale of new units, but is instead offering rental residential units to the public, the new tenant of the rental unit shall be provided a copy of the Airport Disclosure Statement form. The intent of the Airport Disclosure Statement form is to educate and notify the individual that they are living near an airport. The new property owner or new tenant shall forward a signed copy of the Airport Disclosure Statement form to: Scott Robidoux Airport Planner Tucson Airport Authority 7250 South Tucson Boulevard Suite 300 Tucson, AZ 85756 The applicant shall file Form 7460 with the FAA at least 45 days before construction begins. Any cranes used for the project must also be identified with Form 7460. Please file Form 7460 at https://oeaaa.faa.gov/oeaaa/external/portal.jsp. Please do not hesitate to contact me if you have any questions or concerns regarding this comment letter. I can be reached by email at srobidoux@flytucson.com or by telephone at 520-573-4811. Respectfully, Scott Robidoux Airport Planner cc MS file |
| 03/20/2017 | MARTIN BROWN | COT NON-DSD | FIRE | Reqs Change | Same comment as previous review. Provide changes and response letter. "Please show locations of proposed fire hydrants. Refer to section 507.5 of 2012 International Fire Code for guidance." |
| 03/22/2017 | LOREN MAKUS | ENGINEERING | REVIEW | Reqs Change | A complete response letter explaining how each comment from all reviewers has been addressed will be required before the plans are accepted for another review. Please email me or the CDRC coordinator the letter for approval before the plans are submitted again for review. "See revised plans" will not be an accepted response. 1. Address how foundation support requirements in section 5.1 of the geotechnical report will be implemented. 2. Subsurface drain for retaining wall. 3. Provide correct safety factor for infiltration. As previously commented the safety factor requirement is to double the time indicated by the infiltration test to ensure compliance. 4. Please submit a complete drainage report for the project. The drainage report must be revised to meet any changes in code or standards, including the correct application of the safety factor of 2 as required by the floodplain regulations adopted August 9, 2016. 5. Correct the statement made in general note 22. 6. Make sure the drainage report demonstrates that the area discharging to the basin will provide the required volume to achieve 5-year threshold retention. 7. Provide a discussion in the drainage report, incorporating the information from the geotechnical report to demonstrate the need for the use of detention in lieu of retention. Otherwise revise the plan to remove the bleed pipe. 8. . Clearly label grading and SWPPP sheets in the plan set and in the sheet index. 9. Provide a common area designation for the NUOS in the title block. 10. Provide a complete SWPPP meeting all the requirements of the current general permit. Include a copy of the ADEQ checklist, completed to show how each requirement has been fulfilled. 11. The SWPPP sheet is not consistent in the details, descriptions and callouts. Ensure it is consistent with itself and the full plan. 12. Provide detail for the concrete washout. Make sure it is consistent with the requirements of the ADWR general permit. 13. The City of Tucson is not a phase II community. Please correct the reference. 14. The SWPPP notes say the site has no surface bodies including dry/ephemeral washes and wetlands. Please correct this description. Correct all inaccuracies on the plans. 15. Clearly show existing and proposed grades along the south and west boundaries of the project. If more than 2 feet of fill is proposed for any location within the 40 feet of the south boundary or 10 feet of the west boundary, the differential grading procedure must be followed. |
| 03/27/2017 | ANDREW CONNOR | LANDSCAPE | REVIEW | Reqs Change | UNIFIED DEVELOPMENT CODE 4.1 Identification and Descriptive Data A. All improvements and site information, such as adjacent rights-of-way and property lines, shown on the landscape plan will be identical in size and location to those shown on the base plan (site plan or tentative plat). Should amendments be required to the base plan through the review process, the same amendments will be made to the landscape plan which will then be resubmitted along with the base plan. B. The landscape plan will contain the following identification in the lower right corner of each sheet: 1. Legal description and address of site; 2. Cross-reference to: a. Rezoning case; b. Subdivision case; c. Board of Adjustment case; d. Design Development Option case; e. Development Review Board (DRB) case; and/or, f. Any other relevant case number for reviews or modifications that affect the site. 7.6. LANDSCAPING AND SCREENING b. Residential Subdivisions Street landscape borders for residential subdivisions of eight or more lots shall conform to the following standards. (1) Street landscape borders are only required along the exterior boundaries of subdivisions. Landscape borders are not required along front yard street frontages. (2) Walls, fences, or other screening must be placed behind the landscape border. (3) The landscape border must be recorded as common area and maintained by the homeowners association (HOA) for the subdivision. The subdivision CC&Rs shall reference and require compliance with the maintenance standards in Section 7.6.8, Maintenance. The PDSD Director may allow the recording of a public use easement with the subdivision plat in cases where the standards of this section are the only reason for the creation of an HOA. The public use easement shall require the abutting property owner to install and maintain a landscape border in accordance with the standards in this section. Provide landscape buffer along Medina Rd with the following criteria: One canopy tree is required for every 33 linear feet of landscape border or fraction thereof, excluding vehicular ingress or egress points. Fifty percent or more of the area of the street landscape border must be covered with shrubs or vegetative ground cover. The required ground coverage must be achieved within two years from the date of planting. Interior Landscape Border required along site boundary. Provided Interior landscape borders adjacent to Industrial zoned properties. Existing Plants Existing trees and shrubs may be incorporated in a landscaped area. 7.6.5. SCREENING STANDARDS Screening for individual land uses and zones must be provided as determined in Table 7.6.4-1 and in addition to the required landscape borders. Screening is not required between similar uses in accordance with Table 7.6.4-1. A 5' screen wall is required along the East property. Identify screening elements on the landscape plan. 7.7. NATIVE PLANT PRESERVATION Provide a separate NPPO plan. Professional Expertise Preparation of all elements of the Native Plant Preservation Plan and on-site monitoring as required under Section 7.7.5.C.5, On-Site Monitoring, must be performed by a plant professional, such as: 1. An arborist certified by the International Society of Arboriculture; 2. A landscape architect; or, 3. A horticulturist, biologist, or botanist with a minimum B.A. or B.S. in an appropriate arid environment natural resource field. Set Aside Protection Boundaries of all set aside areas must be clearly delineated on an aerial photograph and site plan, or subdivision plat and fenced in accordance with Section 7.7.5.C, Plant Protection During Development, and the Technical Standards Manual for the duration of any construction activities. 7.7.4. GENERAL PROVISIONS AND STANDARDS A. Submittal Requirements If the Set Aside Methodology is selected, an Environmental Resource Report in accordance with Section 7.7.5.A.3 and Section 2-11.4.5, Set Aside Submittal, of the Administrative Manual must be submitted. Site Assessment An Environmental Resource Report (ERR) in accordance with Sections 2-03.5.0, Environmental Resource Report, and 2-11.4.5, Set Aside Submittal, of the Administrative Manual must be prepared for the entire site to determine the general viability, density , and variety of Protected Native Plants within areas on the site . The ERR shall include an assessment of such areas of NUOS and shall prioritize the natural resource value of vegetated areas on the site in conformance with the intent and purpose of this section. Any area left undisturbed as provided in this Section must be shown in the ERR , and no other assessment need be done for such areas. The natural resource value for an area is assessed by the consideration of factors such as: (1) Health, size, density, and variety of native plant species; (2) The visual resource value of the area(s); and, (3) The potential to maximize the preservation of contiguous areas of NUOS both on- and off-site. b. Mitigation Standards A minimum of 30% of the site shall be set aside in perpetuity as NUOS area. The set aside area shall consist of the area(s) with the highest resource value as determined by the ERR or area(s) that is left undisturbed and preserved as provided in Section 5.7, Environmental Resource Zone. c. Federal Endangered Species, Saguaros, and Ironwood Tree Mitigation Standards The ERR shall include an inventory and analysis of all plants listed as Federal Endangered Species, all Saguaros, and all Ironwoods designated as Protected Native Plants in accordance with Section 2-11.0.0, Native Plant Preservation Plan Requirements, of the Administrative Manual. Preservation and mitigation standards for these genus and species shall conform to Section 7.7.5.A.1, Plant Inventory Methodology. 4.5 Set Aside Submittal The requirements of the Environmental Resource Report shall be fulfilled in the assessment of the area(s) of natural resource to be set aside as undisturbed natural open space in lieu of performing a Native Plant Inventory, Analysis, and Plant Preservation and Salvage Plan. In addition, an aerial photograph, taken within a maximum of three years of submittal, is required at a minimum one inch equals 100 feet delineating the natural resource values for areas on the site and the area(s) to be set aside which will be platted and included in Covenants, Conditions, and Restrictions (CC&Rs) as NUOS. Any aerial photograph submitted, which was taken more than one year prior to submittal, shall be accompanied by a note on the plans stating that the site is substantially unchanged from the date of the aerial photograph. Ensure that all zoning and Engineering comments and concerns are addressed. Additional comments may apply. |
| 03/27/2017 | ANDREW CONNOR | NPPO | REVIEW | Reqs Change | 7.7.4. GENERAL PROVISIONS AND STANDARDS A. Submittal Requirements If the Set Aside Methodology is selected, an Environmental Resource Report in accordance with Section 7.7.5.A.3 and Section 2-11.4.5, Set Aside Submittal, of the Administrative Manual must be submitted. Site Assessment An Environmental Resource Report (ERR) in accordance with Sections 2-03.5.0, Environmental Resource Report, and 2-11.4.5, Set Aside Submittal, of the Administrative Manual must be prepared for the entire site to determine the general viability, density , and variety of Protected Native Plants within areas on the site . The ERR shall include an assessment of such areas of NUOS and shall prioritize the natural resource value of vegetated areas on the site in conformance with the intent and purpose of this section. Any area left undisturbed as provided in this Section must be shown in the ERR , and no other assessment need be done for such areas. The natural resource value for an area is assessed by the consideration of factors such as: (1) Health, size, density, and variety of native plant species; (2) The visual resource value of the area(s); and, (3) The potential to maximize the preservation of contiguous areas of NUOS both on- and off-site. b. Mitigation Standards A minimum of 30% of the site shall be set aside in perpetuity as NUOS area. The set aside area shall consist of the area(s) with the highest resource value as determined by the ERR or area(s) that is left undisturbed and preserved as provided in Section 5.7, Environmental Resource Zone. c. Federal Endangered Species, Saguaros, and Ironwood Tree Mitigation Standards The ERR shall include an inventory and analysis of all plants listed as Federal Endangered Species, all Saguaros, and all Ironwoods designated as Protected Native Plants in accordance with Section 2-11.0.0, Native Plant Preservation Plan Requirements, of the Administrative Manual. Preservation and mitigation standards for these genus and species shall conform to Section 7.7.5.A.1, Plant Inventory Methodology. 4.5 Set Aside Submittal The requirements of the Environmental Resource Report shall be fulfilled in the assessment of the area(s) of natural resource to be set aside as undisturbed natural open space in lieu of performing a Native Plant Inventory, Analysis, and Plant Preservation and Salvage Plan. In addition, an aerial photograph, taken within a maximum of three years of submittal, is required at a minimum one inch equals 100 feet delineating the natural resource values for areas on the site and the area(s) to be set aside which will be platted and included in Covenants, Conditions, and Restrictions (CC&Rs) as NUOS. Any aerial photograph submitted, which was taken more than one year prior to submittal, shall be accompanied by a note on the plans stating that the site is substantially unchanged from the date of the aerial photograph. |
| 03/27/2017 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Reqs Change | Based on the FFE being 0.67' higher than the given pad elevation and the approximate rim elevation of public manhole 4107-12 being 2532', lots 1, 2, 3, and 4 will require the installation of a backwater valve when future plumbing activities take place. Similarly, lots 18 and 19 will also require the installation of a backwater valve. [Initial comment: Show the approximate points of connection of the building sewers to the proposed public (?) sewers. If the rim elevation of the next upstream sanitary manhole is higher than the first floor elevation or is less than 12" below the first floor elevation, provide a note on the plans requiring the installation of a backwater valve when future plumbing activities take place. Reference: Section 715.1, IPC 2012, as amended by the City of Tucson.] |
| 03/30/2017 | AHINES2 | ZONING-DECISION LETTER | REVIEW | Reqs Change | This review has been completed and resubmittal is required. Please resubmit the following items: 1) Two rolled sets of the plans 2) All approved documents submitted previously 3) A disk containing all items submitted 4) All items requested by review staff 5) All items needed to approve these plans 6) A comment response letter with detailed statements. |
| 03/30/2017 | AHINES2 | PIMA COUNTY | WASTEWATER | Reqs Change | Provide a separate submittal and payment to PC RWRD for the DP16-0176. Please reach out to PC RWRD. Contact information is below. That is a negative we did not receive anything yet. Respectfully Hussein Al Zubaidi Engineering Plans Tech. Regional Wastewater Reclamation Department 201 N. Stone Ave., 1st Floor Tucson, AZ 85701 (520) 724-6404 |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 04/04/2017 | MMENDIB1 | OUT TO CUSTOMER | Completed |