Permit Number: DP16-0168
Parcel: 10320075B

Review Status: Completed

Review Details: DEV PKG

Permit Number - DP16-0168
Review Name: DEV PKG
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/23/2016 KROBLES1 START PLANS SUBMITTED Completed
09/23/2016 AHINES2 OTHER AGENCIES PIMA ASSN OF GOVTS Passed For notification purposes only.
09/23/2016 TIM ROWE PIMA COUNTY WASTEWATER Passed Plans do not require review per Sewer Submittal Review Worksheet.
09/23/2016 LIZA CASTILLO UTILITIES TUCSON ELECTRIC POWER Passed For notification purposes only.
09/23/2016 JENNIFER STEPHENS PIMA COUNTY ADDRESSING Passed Plans do not require review per Addressing Submittal Review Worksheet.
09/23/2016 AHINES2 OTHER AGENCIES U. S. POST OFFICE Passed For notification purposes only.
09/23/2016 MARTIN BROWN COT NON-DSD FIRE Reqs Change The turn-around/hammerhead tee at south-east corner of project does not appear to meet standards. Each "leg" of the tee should be 57'. Please review and revise.
Additional "No Parking - Fire Lane" signs will be required along and at end of aforementioned parking lot.
09/23/2016 AHINES2 UTILITIES SOUTHWEST GAS Passed For notification purposes only.
10/06/2016 STEVE SHIELDS ZONING REVIEW Reqs Change CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Steve Shields
Principal Planner

PROJECT: Via Elegante at Tucson Mountain
Development Package (1st Review)
DP16-0168

TRANSMITTAL DATE: April 10, 2016

DUE DATE: April 20, 2016

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is September 21, 2017.

2-06.4.9 - Information on Proposed Development
1. The following information on the proposed project shall be shown on the drawing or added as notes.

2. 2-06.4.9.H.5 - Provide PAAL width dimensions for all PAALs providing access to proposed vehicle parking spaces.

3. 2-06.4.9.R - There is a proposed accessible vehicle parking space shown along the south property line. This accessible space needs to be relocated so that it is closer to the building and that there is an accessible route provided to an accessible entrance to the building.

4. 2-06.4.9.R - There is a proposed accessible vehicle parking space shown along the north side of the northern most parking area. This accessible space needs to be relocated so that it is closer to the building and that there is an accessible route provided to an accessible entrance to the building.

5. 2-06.4.9.R - There are two (2) accessible vehicle parking spaces shown northeast of the entrance canopy. Clearly show the accessible route from the accessible parking spaces to an accessible entrance of the building.

6. 2-06.4.9.R - Clearly show the accessible routes from all accessible vehicle parking spaces to an accessible entrance of the building.

If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
10/10/2016 SSHIELD1 ZONING HC REVIEW Reqs Change See Zoning comments
10/13/2016 JOE LINVILLE LANDSCAPE REVIEW Approv-Cond Revise as may be requested by other agencies.
10/14/2016 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Reqs Change Revise the site drawing to include the following existing utility information:
a. The location and size of water wells, water pumping plants, water reservoirs, water lines, and fire hydrants.
b. If an on-site sewage disposal system is or is to be located on site, show the location of all individual components for the disposal system, including any reserve areas and indicate the required separation distances.
Reference: City of Tucson Administrative Manual, Section 2-06.4.8D and Section 107.2.1, IBC 2012.
10/14/2016 JOHN BEALL COT NON-DSD COMMUNITY PLANNING Passed
10/19/2016 ZELIN CANCHOLA COT NON-DSD TRAFFIC Approved
10/20/2016 GLENN HICKS COT NON-DSD PARKS & RECREATION Approved No existing or proposed Tucson Parks and Recreation facilities are affected by this development.

Howard B. Dutt, RLA
Landscape Architect
Tucson Parks & Recreation
(520) 837-8040
Howard.Dutt@tucsonaz.gov
10/24/2016 LOREN MAKUS ENGINEERING REVIEW Approved
10/26/2016 AHINES2 ZONING-DECISION LETTER REVIEW Reqs Change This review has been completed and resubmittal is required. Please resubmit the following items:

1) Two rolled sets of the plans
2) All approved documents submitted previously
3) A disk containing all items submitted
4) All items requested by review staff
5) All items needed to approve these plans

Final Status

Task End Date Reviewer's Name Type of Review Description
10/27/2016 ARUIZ1 OUT TO CUSTOMER Completed