Permit Number: DP16-0144
Parcel: 11704214A

Address:
58 E 5TH ST

Review Status: Completed

Review Details: DEV PKG - RESUBMITTAL

Permit Number - DP16-0144
Review Name: DEV PKG - RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
10/27/2016 PGEHLEN1 START PLANS SUBMITTED Completed
10/27/2016 PGEHLEN1 COT NON-DSD ENVIRONMENTAL SERVICES Reqs Change Trish,

The City of Tucson - Environmental Services Department has completed our review of the revised Development Plan for the 7th Avenue Commons project.

The solid waste compactor is now located on the south side of the parking area access lane in the west parking lot area. The compactor proposed for this site is the "Mini-MAC Apartment Compactor" manufactured by the Marathon Equipment Company. This compactor has a 2 cubic yard compaction container which is mounted on casters. The casters allow the compaction container to be moved to the container pick-up area. The container pick-up area, as shown on Figure 4 of 25 of the Development Plans, would be along Echols Avenue to the immediate east of the parking lot area. Therefore, the vehicle servicing the compactor would not have to enter the parking lot area. This proposed location of the compactor is acceptable and would be approved by Environmental Services.

Before final approval of this waste management plan, the waste generation calculations and the proposed frequency of servicing of the compactor would have to be reviewed by Environmental Services.

Please let me know if there are any questions concerning this review.

Tom Ryan
City of Tucson - Environmental Services Department
10/27/2016 GARY WITTWER COT NON-DSD TDOT Approv-Cond Please have the Landscape Architect add the following notes on the plans.

City of Tucson
Department of Transportation
Standard Notes for Planting in ROW

1. It is the owner's responsibility to keep the Sight Visibility Triangles (SVT), and the pedestrian access area clear of vegetation at all times, per Land Use Code (LUC) section.
2. It is the owner responsibility to keep a 5' wide by 7' tall clear pedestrian access open across the entire property.
3. It is the owner responsible to keep vegetation from growing past the curb line clear, and keep a 15' high clear zone over the travel lane.
4. Final plant locations must be in compliance with all utility setback requirements.
5. The owner understands that if the City of Tucson Transportation Department or any utility company needs to work within the ROW in the landscaped area, plants and irrigation may be destroyed without replacement or repair.
6. The owner takes full liability for this landscape and irrigation, and any damage to roadway, sidewalk and utilities.
7. The only private irrigation equipment that is allowed within the ROW are lateral lines, tubing and emitters that are not under constant pressure. All other equipment must be on private property. (excluding water meter)
8. Contractor to obtain a Right Of Way permit prior to construction within the right-of-way.
10/31/2016 SSHIELD1 ZONING HC REVIEW Approved
10/31/2016 STEVE SHIELDS ZONING REVIEW Reqs Change CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Steve Shields
Principal Planner

PROJECT: 7th Avenue Commons
Development Package (2nd Review)
DP16-0144

TRANSMITTAL DATE: October 31, 2016

DUE DATE: October 31, 2016

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is August 22, 2017.

CONTENT REQUIREMENTS

1. This comment was not addressed. The IID case number provided is not correct and should be T16SA00150. 2-06.4.3 - As you will be using the Downtown Area Infill Incentive District (IID) for this plan provide the IID case number adjacent to the title block on all sheets.

2. This comment was not address. 2-06.4.2.B - Identify all streets that abut the subject property on the location map.

2-06.4.7 - General Notes
The following general notes are required. Additional notes specific to each plan are required where applicable.

2-06.4.7.A - Zoning and Land Use Notes

3. This comment was not address. The development package cannot be approved until the IID is completed. 2-06.4.7.A.6.a - Provide a general note stating the IID case number, date of approval, what has been modified, if applicable conditions of approval

2-06.4.9 - Information on Proposed Development
The following information on the proposed project shall be shown on the drawing or added as notes.

4. A hold has been put on building permit T16CM06538 to ensure that the lot combination is completed prior to issuing the certificate of occupancy. 2-06.4.9.A - As the main site is made up of three (3) parcels, 117-04-214A, 117-04-214D & 117-04-214F, a lot combination is required. Provide a copy of the approved Pima County Combination Request from with your next submittal.

5. 2-06.4.9.H.5.a - As the provided number of provided vehicle parking spaces, 34, does not meet the required number of vehicle parking spaces, 50, the IID will need to be approved prior to approval of the development package.

If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package.
10/31/2016 ZELIN CANCHOLA COT NON-DSD TRAFFIC Approv-Cond October 30, 2016
ACTIVITY NUMBER: DP16-0144
PROJECT NAME: 7th Ave Commons
PROJECT ADDRESS: 58 e 5th Street
PROJECT REVIEWER: Zelin Canchola TDOT

TDOT will support any TSMR or relief via the IID for teh sight visibility triangle from the driveway to Nichols Ave. According to technical standards #1 in section 10-01 5.2

5.2 Sight Distances
A. The length of the stem side of the sight triangle is 20 feet, measured from a point specified below.
B. The length and location of the through street side of the sight triangle for near side/far side is determined according to the following criteria.
1. On any PAAL or on a street that generates an ADT of 140 or less and intersects a local road, no sight triangle is required. The minimum perimeter yard required in Article 6, Dimensional Standards and Measurements, of the UDC prevails.

Nichols does not generate 140 or more. With the TDOT Links project the south end will be closed.

Zelin Canchola
TDOT Engineering Review
11/01/2016 LOREN MAKUS ENGINEERING REVIEW Approv-Cond Approved pending inclusion of waste stream calculaton and service frequency. In addition to the waste stream calculation from the technical standard, note that Chapter 15 of city code requires a minimum of 45 gallons per unit. The volume may be reduced proportionately to the compactor volume reduction.
11/01/2016 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Completed
11/01/2016 ANDREW CONNOR LANDSCAPE REVIEW Approv-Cond Conditional approval granted pending approval of the IID, submittal of shade plan and ensure that all Zoning comments and concerns are addressed.
11/08/2016 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Needs Review
11/08/2016 PGEHLEN1 DESIGN PROFESSIONAL REVIEW Needs Review

Final Status

Task End Date Reviewer's Name Type of Review Description
11/08/2016 PGEHLEN1 OUT TO CUSTOMER Completed