Permit Number: DP16-0116
Parcel: 13015001A

Address:
4646 E 22ND ST

Review Status: Completed

Review Details: SITE and/or GRADING

Permit Number - DP16-0116
Review Name: SITE and/or GRADING
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/20/2016 MARTIN BROWN FIRE REVIEW Approved
07/28/2016 STEVE SHIELDS ZONING REVIEW Reqs Change CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Steve Shields
Principle Planner

PROJECT: Chapman Audi - Addition & Remodel
Development Package (1st Review)
DP16-0116

TRANSMITTAL DATE: July 29, 2016

DUE DATE: August 11, 2016

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is July 13, 2016.

2-06.3.0 FORMAT REQUIREMENTS

1. 2-06.3.12 - An index of sheets in the development package shall be provided on the first sheet.

CONTENT REQUIREMENTS

2. 2-06.4.1 - The name, mailing and email addresses, and phone number of all registrant(s), and other person(s), firm(s), or organization(s) that prepared the development package documents shall be provided on the right half of the cover sheet

3. 2-06.4.3 - Provide the development package case number, DP16-0116, adjacent to the title block on all sheets.

2-06.4.7 - General Notes
The following general notes are required. Additional notes specific to each plan are required where applicable.

2-06.4.7.A - Zoning and Land Use Notes

2-06.4.7.A.8 - For development package documents provide:

4. 2-06.4.7.A.8.a - The square footage shown for the "Acura Facility New Vehicle Delivery" in the "BUILDING AREA CALCULATIONS" is not the same as what is shown on DP12-0082. Clarify the difference.

5. 2-06.4.7.A.8.b - Remove the reference to "ACTUAL LOT COVERAGE" from the plan as it is not applicable.

6. 2-06.4.7.A.8.c - Provide building area expansion/reductions calculation on the plan.

2-06.4.9 - Information on Proposed Development
The following information on the proposed project shall be shown on the drawing or added as notes.

7. 2-06.4.9.H.5.a - The required and provided number of accessible vehicle parking spaces are not correct. Per 2012 IBC Table 1106.1 when 423 vehicle parking spaces are provide 9 accessible vehicle parking spaces are required. It appears that there are 10 provided. Also provide the number of van accessible space required and provided on the plan.

8. 2-06.4.9.H.5.a - Detail 1 Sheet 3 provide a sign mounting height dimension from the bottom of the van accessible sign to grade. This dimension should be 7'-0".

9. 2-06.4.9.H.5.d - The required number of short-term bicycle parking spaces is not correct. Per UDC Table 7.4.8-1: Minimum Required Bicycle Parking Spaces, RETAIL TRADE USE GROUP, Vehicle Rental and Sales, 2 short-term bicycle parking spaces are required.

10. 2-06.4.9.H.5.d - Remove all references to "CLASS II" bicycle parking from the plan.

11. 2-06.4.9.H.5.d - The 2'-6" dimension shown from the center of rack to the wall on Detail 5 Sheet 3 is not correct and should be shown from the edge of rack see UDC Article 7.4.9.B2.g and figure 7.4.9-C.
12. 2-06.4.9.H.6 -

13. 2-06.4.9.Q - Provide the square footage of each building within the footprint.

14. 2-06.4.9.R - Sheet 2 shows a sidewalk along the west side of "SERVICES ADVISORS" area, sheet 4 does not. It's not clear that the accessibility requirements are meet from the building to the two (2) accessible vehicle parking spaces to the south.

If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
07/29/2016 SSHIELD1 ADA REVIEW Passed
07/29/2016 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Completed
07/29/2016 SSHIELD1 H/C SITE REVIEW Reqs Change See Zoning comments
08/10/2016 ANDREW CONNOR LANDSCAPE REVIEW Reqs Change ADMINISTRATIVE MANUAL SECTION 2-10.0.0: LANDSCAPE PLAN REQUIREMENTS
Identification and Descriptive Data
All improvements and site information, such as adjacent rights-of-way and property lines, shown on the landscape plan will be identical in size and location to those shown on the base plan (site plan or tentative plat). Should amendments be required to the base plan through the review process, the same amendments will be made to the landscape plan which will then be resubmitted along with the base plan. (General comment, pertaining to plan contents)
2-06.3.0 FORMAT REQUIREMENTS
2-06.3.12 - An index of sheets in the development package shall be provided on the first sheet.
2-06.4.3 - Provide the development package case number, DP16-0116, adjacent to the title block on all sheets.
7.6.2. APPLICABILITY
Buildings Greater Than 10,000 Square Feet
On sites where the gross floor area of the existing building(s) is more than 10,000 square feet, expansion in square footage of land area, floor area, lot coverage, or vehicular use area as follows:
a. If the expansion is less than 25%, the standards of this section apply only to the proposed expansion. Existing development on the site is subject to the zoning standards in effect at the time the existing development received zoning approval.
b. If the expansion is 25% or greater or if expansions as of February 15, 1991, cumulatively result in a 25% or greater expansion in land area, floor area, lot coverage, or vehicular use area, the standards of this section apply to the entire site.
Provide expansion calculation and previously approved site or development plan
Ensure that all Zoning and Engineering comments and concerns are addressed.
Additional comments may apply.
08/11/2016 ANDREW CONNOR NPPO REVIEW Approved
08/16/2016 LOREN MAKUS ENGINEERING REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
08/19/2016 ARUIZ1 OUT TO CUSTOMER Completed