Permit Number: DP16-0106
Parcel: 117050490

Address:
417 N HERBERT AV

Review Status: Completed

Review Details: DEV PKG - RESUBMITTAL

Permit Number - DP16-0106
Review Name: DEV PKG - RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
12/02/2016 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Completed
12/02/2016 LOREN MAKUS ENGINEERING REVIEW Approved
12/02/2016 KROBLES1 START PLANS SUBMITTED Completed
12/13/2016 CLAURIE1 DESIGN PROFESSIONAL REVIEW Denied PD16-0106/ IID-16-03 Comments

1. Drawings comprised of Development Plan Package dated 12/01/2016. 3 sheets.

2. Sidewalk width has been reduced to 7’ wide. This was previously indicated as 8’ wide. The existing sidewalk is 13’ wide and is being reconfigured to accommodate restaurant seating. Per the discussion with the applicant at the August 29, 2016 pre-application meeting the sidewalk is an important urban design component and 8’ is a reasonable minimum width. It should not be further reduced.

3. Regarding the Streetscape Shading requirement, I don’t think it’s a problem but I haven’t seen any documentation.

4. Requests in July 24, COT Planning & Development Services letter regarding the Development Package review that do not appear to have been addressed:
a. provide floor area and height of buildings (gross floor area of project is noted but not individual structures)
b. provide first floor elevations

5. "Total Paved Area” of development is noted as “0”. This doesn’t seem correct — aren't Exterior Food Service and Exterior Service Yards paved?

6. Long Term Bicycle Parking requirement is noted as 6 spaces, with 0 spaces provided. This should be confirmed; I don’t remember what was finally agreed upon about this in the last meeting.

7. Note from Thomas Ryan re: waste collection — need to indicate frequency of waste collection.
12/15/2016 STEVE SHIELDS ZONING REVIEW Approv-Cond CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Steve Shields
Principle Planner

PROJECT: Corbett Brewery
Development Package (2nd Review)
DP16-0106

TRANSMITTAL DATE: December 15, 2016

Zoning conditionally approves the development package subject to the following;

A temporary revocable easement (TRE) is required for the proposed seating located within the right-of-way. Zoning acknowledges that John Cahill has been contacted and the process has been started. A hold has been put on the certificate of occupancy for T16CM07773 until the TRE is completed.

If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov
12/16/2016 ANDREW CONNOR LANDSCAPE REVIEW Approved
12/16/2016 LBOJORQ1 ZONING-DECISION LETTER REVIEW Needs Review

Final Status

Task End Date Reviewer's Name Type of Review Description
12/16/2016 LBOJORQ1 OUT TO CUSTOMER Completed