Permit Number: DP16-0098
Parcel: 116232100

Address:
993 S FREEWAY

Review Status: Completed

Review Details: GRADING

Permit Number - DP16-0098
Review Name: GRADING
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/16/2016 PAUL BAUGHMAN ENGINEERING REVIEW Approved August 16, 2016
FLOODPLAIN USE PERMIT NO.: T16OT00708
ADDRESS: 993 S Freeway, Tucson Arizona 85745
PROPERTY OWNER: Lowell Carhart
80 Roselyn Forest Lane, Charlottsville, VA 22901

The applicant is authorized to use a portion of the City of Tucson Flood Hazard Area per the Downtown Airort Wash delineation, specifically described as:

A portion of Parcel 116232100, South Yard Drill Track Block 5

For the purpose of adding fill and other development related features such as gravel, pavement and a retention basin per DP16-0098.

The applicant agrees to comply with City of Tucson Floodplain and Erosion Hazard, and Watercourse Amenities, Safety and Habitat regulations, and is particularly bound by the conditions stated below. Violation of any of the conditions stated or referred to below, as determined by the City Engineer, shall be grounds for revocation of this permit. Responsibility for renewal of this permit, if necessary, is with the applicant. Issuance of this permit does not constitute a waiver of other requirements contained in the Tucson City Code, Unified Development Code, or any other Federal, State, County, or local regulation. No use other than as permitted herein is allowed. Additional uses allowed under City of Tucson Floodplain and Erosion Hazard Regulations and Watercourse Amenities, Safety, and Habitat regulations require the issuance of an additional Floodplain Use Permit.

The following 8 conditions apply to this permit:

1) This permit becomes invalid and is subject to additional floodplain review, if any required development changes the placement of the fill, gravel, pavement or retention basin, or, if there is any further disturbance within the floodplain other than that outlined in this application. This floodplain use permit may be subject to conditions or restrictions designed to reduce or mitigate the potential damage or hazard to life or property resulting from the construction of the above cited improvements within the regulatory floodplain, floodway or erosion hazard areas as determined by the project engineer and accepted by the City of Tucson.
2) Except as approved by the City Engineer prior to the start of construction, development under this permit shall not obstruct, retard or divert the existing flow of floodwaters from or to adjacent properties.
3) All work shall conform to the approved site plan sheets for the placement of fill, pavement, gravel and retention basin, which are made part of this permit.
4) Within 5 (five) days of issuance of this permit, and through completion of the project, notification must be posted and maintained in a conspicuous place on the job site stating "CONSTRUCTION PROCEEDING UNDER REQUIREMENTS OF CITY OF TUCSON FLOODPLAIN USE PERMIT # T16OT00708 FOR INFORMATION PLEASE CALL 791-5550."
5) This Floodplain Use Permit and plans shall be kept in a readily accessible location on site at all times.
6) Any additional future disturbance of the floodplain shall have separate floodplain use permit applications submitted to this office for review and approval.
7) See the associated activity DP16-0098
8) This permit is specific to the improvements for 993 S Freeway Tucson, AZ as indicated on the approved plans. It shall not apply to any other structure or property, whether attached or unattached, not specified under this permit.

Renewal of this permit will require a new application, review and approval of that application by the City of Tucson, Planning & Development Services Department, Engineering Division. This permit may be renewed for up to one year, in the absence of Registered Plant authorization, at the sole discretion of the City Engineer or designated representatives.

This Floodplain Use Permit will be automatically revoked and becomes invalid if conditions are not complied with, as set forth in this permit.

APPLICANT NAME: Ken Perry
ADDRESS: 505 W Wetmore Road, Tucson, AZ 85705
PHONE: 520-620-9870
CONTRACTOR: TBD
ADDRESS: TBD
PHONE: TBD

(EXPIRATION DATE) Month: _08 Day: 16_ Year: 2017
08/17/2016 STEVE SHIELDS ZONING REVIEW Approved
08/17/2016 ANDREW CONNOR NPPO REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
08/17/2016 KROBLES1 OUT TO CUSTOMER Completed