Permit Number: DP16-0090
Parcel: 131010060

Address:
5346 E 22ND ST

Review Status: Completed

Review Details: SITE and/or GRADING

Permit Number - DP16-0090
Review Name: SITE and/or GRADING
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/21/2016 MARTIN BROWN FIRE REVIEW Approved
06/28/2016 PAUL BAUGHMAN ENGINEERING REVIEW Reqs Change DATE: July 1, 2016
DUE DATE: July 18, 2016
SUBJECT: Site
TO: Jeff Stanley
LOCATION: 5346 E 22nd Street
REVIEWERS: Paul Baughman, PE, CFM
ACTIVITY: DP16-0090
SUMMARY: Engineering Division of Planning and Development Services Department has received and reviewed the proposed Development Plan Package. The following items need to be addressed:
1) Per AM 2-06.4.3 please add the case number (DP16-0090).
2) Per AM 2-06.4.9N2 please update keynote 6 on development package to reflect 6" depressed landscape area.
3) Keynotes 8 and 13 are calling out illuminated Dunkin donuts Signs - "Exit" and "Enter" in areas where keynote 18 is calling out sight visibility triangles. Please clarify how this is complying with TSM 10-01.5.1.
4) Keynote 20 is calling out a monument sign in an area where keynote 17 is calling out a sight visibility triangle. Please clarify how this is complying with TSM 10-01.5.1.
5) There is line work for curb shown along the west side of the plan should be called out by keynote per AM 2-06.4.9H1. Please also fix break in curb line work where existing contour line work crosses curb line work.
6) There are keynotes listed on sheet 4 that are not called out in the plan view. Please update as appropriate.
7) Per AM 2-06.4.9N4 please show the direction the parking lot drains to near the proposed dumpster enclosure. If the parking lot drains towards any of the proposed curb along the south side of the lot please provide curb openings per UDC 7.6.6C2.
8) Per AM 2-06.4.9N7 please show points where drainage from the property south of this site is entering the site. Show discharge from offsite watershed(s).
9) Per TSM Section 10-01.3.2C (Figure 6) please show minimum 25' radius curb returns at both entry/exit points. Google street view shows one of the entry/exit points has a curb cut instead of curb returns that needs to be replaced. Per TSM Section 10-01.3.2B2 please specify curb as vertical curb. Update keynote 6 accordingly.
10) Per TSM 8-01.8.0A please provide a waste stream calculation as part of the plans set.
11) Per AM 2-06.4.8C please provide dimensions for and between sidewalk, curbs, street and right-of-way limits.
If you have any comments questions or wish to discuss new information, please call or email me at 520-837-5007 or paul.baughman@tucsonaz.gov.
07/14/2016 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Completed
07/18/2016 STEVE SHIELDS ZONING REVIEW Reqs Change CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Steve Shields
Principle Planner

PROJECT: Dunkin Donuts - 5346 E. 22nd Street
Development Package (1st Review)
DP16-0090

TRANSMITTAL DATE: July 18, 2016

DUE DATE: July 18, 2016

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

The review comments include the actual standard first with the applicable Administrative Manual section number and the following paragraph is the actual comment related to the specific item that must be addressed. If you need to review the sections listed below click on the link or copy it in the address bar of your internet program. http://www.amlegal.com/nxt/gateway.dll/Arizona/tucson_az_udc/administrativemanual?f=templates$fn=default.htm$3.0$vid=amlegal:tucson_udc_az

This link will take you directly to the section used for the standards review. The UDC & TSM requirements are in the Unified Development Code and can be viewed at the same web link as above

Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is June 16, 2016.

1. 2-06.4.3 - Provide the street adjacent to the title block on each sheet.

2. 2-06.4.9.H.5.a - Detail 4 sheet 3 provide a sign mounting height dimension for the van accessible sign. This should be 7'-0".

3. 2-06.4.9.H.5.a -Demonstrate on the plan that there is an accessible route between accessible vehicle parking spaces to the accessible building entrance of that meets the requirements of 2012 IBC Chapter 11 and the ICC A117.1-2009. Show running and cross slopes and spot elevations.

Once the above comments are addressed Zoning will provide an over-the-counter review.

If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
07/18/2016 ANDREW CONNOR NPPO REVIEW Approved
07/18/2016 ANDREW CONNOR LANDSCAPE REVIEW Reqs Change The landscape plan has been reviewed by the Landscape Section but cannot approve the plan until all Zoning and Engineering, comments, concerns, and appropriate revisions have been addressed.

ARTICLE 7: DEVELOPMENT STANDARDS

7.6. LANDSCAPING AND SCREENING

7.6.2. APPLICABILITY

On sites where the gross floor area of the existing building(s) is 10,000 square feet or less, expansions in square footage of land area, floor area, lot coverage, or vehicular use area as follows.

If the expansion is less than 50%, the standards of this section apply only to the proposed expansion. Existing development on the site is subject to the zoning standards in effect at the time the existing development received zoning approval.

Provide previously approved landscape plan if available.

Additional comments may apply.
07/18/2016 SSHIELD1 H/C SITE REVIEW Reqs Change See Zoning comments
07/18/2016 SSHIELD1 ADA REVIEW Passed