Permit Review Detail
Review Status: Completed
Review Details: SITE and/or GRADING
Permit Number - DP16-0062
Review Name: SITE and/or GRADING
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/08/2016 | MARTIN BROWN | FIRE | REVIEW | Approved | |
| 04/26/2016 | SSHIELD1 | H/C SITE | REVIEW | Approved | |
| 04/26/2016 | STEVE SHIELDS | ZONING | REVIEW | Approved | |
| 04/29/2016 | JOE LINVILLE | LANDSCAPE | REVIEW | Approved | |
| 05/03/2016 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Reqs Change | The rim elevation of the next upstream sanitary manhole (#6646-02, 2355.1') is less than 12" below the first floor elevation (2355.8'). A backwater valve will be required per Section 715.1, IPC 2012, as amended by the City of Tucson. |
| 05/05/2016 | LOREN MAKUS | ENGINEERING | REVIEW | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 05/24/2016 | RBENT1 | OUT TO CUSTOMER | Completed |