Permit Review Detail
Review Status: Completed
Review Details: DEV PKG - RESUBMITTAL
Permit Number - DP16-0047
Review Name: DEV PKG - RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/23/2016 | RBENT1 | START | PLANS SUBMITTED | Completed | |
| 05/26/2016 | MARTIN BROWN | COT NON-DSD | FIRE | Approved | |
| 05/26/2016 | PAUL BAUGHMAN | ENGINEERING | REVIEW | Approved | |
| 05/27/2016 | DAVID RIVERA | ZONING | REVIEW | Approved | |
| 06/14/2016 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Completed | |
| 06/20/2016 | PGEHLEN1 | COT NON-DSD | ENVIRONMENTAL SERVICES | Reqs Change | The Development Plan has been reviewed on behalf of the Environmental Services Dept. and the following will need to be addressed on the resubmittal: 1. The new location of the enclosure requires the collection truck to travel the loop road and make the turn at the clubhouse. The turning templates provided on the plan show the truck cannot make this turn. Provide a location for the enclosure where the collection truck can service the containers while meeting the maneuvering requirements in TSM 8-01.5.3.E. , and without exceeding the 80 ft. maximum backing distance as specified in TSM 8-01.5.3.F. Show the path of the collection vehicle as it leaves the loop road and turns back onto Club Drive to exit. 2. Revise Detail C on Sheet 8 to show the required #4 rebar, 12” O.C. both ways instead of the woven wire fabric. 3. Revise the Double Enclosure Detail K on Sheet 8 to match Figure 3 in TSM Section 8. For example, the post barricades are to be filled with concrete and the walls are to be constructed per TSM Figure 2. Note on the detail the gate face is to be a minimum 1/8” thick steel. If there are any questions, I can be reached at kperry@perryengineering.net www.perryengineering.net Image result for facebook email signature http://findicons.com/files/icons/2052/social_network/32/linkedin.png Ken Perry, Principal PE, LEED AP 505 W. Wetmore Road Tucson, Arizona 85705 Office 520.620.9870, ext. 1 CONFIDENTIALITY NOTICE: This E-mail and any attachments are private and are intended only for the use of the addressee, and may contain privileged and/or confidential information. If you are not the intended recipient, you are hereby notified that the use, distribution, or copying of this E-mail and/or the attachments is strictly prohibited. |
| 06/21/2016 | JOE LINVILLE | LANDSCAPE | REVIEW | Approved | |
| 06/23/2016 | AHINES2 | ZONING-DECISION LETTER | REVIEW | Reqs Change | This review has been completed and resubmittal is required. Please resubmit the following items: 1) Two rolled sets of the plans 2) A disk containing all items submitted 3) All items requested by review staff 4) All items needed to approve these plans |
| 06/23/2016 | JOHN BEALL | COT NON-DSD | COMMUNITY PLANNING | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 07/01/2016 | RBENT1 | OUT TO CUSTOMER | Completed |