Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: DP16-0047
Parcel: 13314233C

Review Status: Completed

Review Details: DEV PKG - RESUBMITTAL

Permit Number - DP16-0047
Review Name: DEV PKG - RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
05/23/2016 RBENT1 START PLANS SUBMITTED Completed
05/26/2016 MARTIN BROWN COT NON-DSD FIRE Approved
05/26/2016 PAUL BAUGHMAN ENGINEERING REVIEW Approved
05/27/2016 DAVID RIVERA ZONING REVIEW Approved
06/14/2016 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Completed
06/20/2016 PGEHLEN1 COT NON-DSD ENVIRONMENTAL SERVICES Reqs Change The Development Plan has been reviewed on behalf of the Environmental Services Dept. and the following will need to be addressed on the resubmittal:

1. The new location of the enclosure requires the collection truck to travel the loop road and make the turn at the clubhouse. The turning templates provided on the plan show the truck cannot make this turn. Provide a location for the enclosure where the collection truck can service the containers while meeting the maneuvering requirements in TSM 8-01.5.3.E. , and without exceeding the 80 ft. maximum backing distance as specified in TSM 8-01.5.3.F. Show the path of the collection vehicle as it leaves the loop road and turns back onto Club Drive to exit.

2. Revise Detail C on Sheet 8 to show the required #4 rebar, 12” O.C. both ways instead of the woven wire fabric.

3. Revise the Double Enclosure Detail K on Sheet 8 to match Figure 3 in TSM Section 8. For example, the post barricades are to be filled with concrete and the walls are to be constructed per TSM Figure 2. Note on the detail the gate face is to be a minimum 1/8” thick steel.

If there are any questions, I can be reached at kperry@perryengineering.net








www.perryengineering.net



Image result for facebook email signature http://findicons.com/files/icons/2052/social_network/32/linkedin.png



Ken Perry, Principal

PE, LEED AP



505 W. Wetmore Road

Tucson, Arizona 85705

Office 520.620.9870, ext. 1




CONFIDENTIALITY NOTICE:

This E-mail and any attachments are private and are intended only for the use of

the addressee, and may contain privileged and/or confidential information.

If you are not the intended recipient, you are hereby notified that the use,

distribution, or copying of this E-mail and/or the attachments is strictly prohibited.
06/21/2016 JOE LINVILLE LANDSCAPE REVIEW Approved
06/23/2016 AHINES2 ZONING-DECISION LETTER REVIEW Reqs Change This review has been completed and resubmittal is required. Please resubmit the following items:

1) Two rolled sets of the plans
2) A disk containing all items submitted
3) All items requested by review staff
4) All items needed to approve these plans
06/23/2016 JOHN BEALL COT NON-DSD COMMUNITY PLANNING Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
07/01/2016 RBENT1 OUT TO CUSTOMER Completed