Permit Review Detail
Review Status: Completed
Review Details: GRADING
Permit Number - DP16-0011
Review Name: GRADING
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/10/2016 | ELIZABETH LEIBOLD | ENGINEERING | REVIEW | Reqs Change | DATE: February 10, 2016 TO: William Burger SUBJECT: 2154 S Little Dipper Drive Grading Plan Review LOCATION: Wildcat Pass S02-008 lot 26 REVIEWER: Elizabeth Leibold, P.E. ACTIVITY NUMBERS: T15CM07842 (building plan set), DP16-0011 (Development Package - Grading) COMMENTS: 1) Admin Man Sec.2-06.4.7: Address the remaining comments: a) Plans shall not include white out areas - resubmit with no marked out or white out. b) Provide sequential numbered sheets in next submittal. (Missing sheet 1.2?) Landscape plans may not be required for this Development Package submittal - confirm with Zoning or Landscaping staff regarding this requirement for this custom grading lot development. c) Add "DP16-0011" to grading plan sheet and any other sheets within the Development Package. d) Add the following as a note: (if applicable) no slopes shall exceed 2:1(H:V) unless geotechnical report recommendations with proposed slope design are provided to the City for review. 2) Tech Man Sec.2-01.4.C: It appears that 1.5:1(H:V) slopes may be proposed on sheet 1.1. A Soils Report with geotechnical recommendations will be needed for slopes greater than 2:1(H:V). If slopes are proposed to be 2:1(H:V) or less steep, revise and clarify slope grade and label slopes with gradient proposed (i.e. 2:1(H:V), or 3:1(H:V) etc) on grading planview. Elizabeth Leibold, P.E., CPM, CFM Civil Engineer Engineering Division Planning & Development Services Dept |
| 02/11/2016 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | Zoning cannot approve until the grading plan is approved by Engineering. |
| 02/11/2016 | ANDREW CONNOR | NPPO | REVIEW | Reqs Change | Ensure that all Zoning and Engineering comments and concerns are addressed. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 02/11/2016 | AROMERO4 | OUT TO CUSTOMER | Completed |