Permit Review Detail
Review Status: Completed
Review Details: RESUB - SITE/GRADING ALL
Permit Number - DP16-0010
Review Name: RESUB - SITE/GRADING ALL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/07/2016 | SSHIELD1 | H/C SITE | REVIEW | Reqs Change | See Zoning comments |
| 04/07/2016 | STEVE SHIELDS | ZONING | REVIEW | Needs Review | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Steve Shields Lead Planner PROJECT: 742 E. Lee Street Development Package (2nd Review) DP16-0010 TRANSMITTAL DATE: April 7, 2016 DUE DATE: April 13, 2016 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM). The review comments include the actual standard first with the applicable Administrative Manual section number and the following paragraph is the actual comment related to the specific item that must be addressed. If you need to review the sections listed below click on the link or copy it in the address bar of your internet program. http://www.amlegal.com/nxt/gateway.dll/Arizona/tucson_az_udc/administrativemanual?f=templates$fn=default.htm$3.0$vid=amlegal:tucson_udc_az This link will take you directly to the section used for the standards review. The UDC & TSM requirements are in the Unified Development Code and can be viewed at the same web link as above Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is January 26, 2017. Based on the provided last approved site plan there have been modifications to the vehicle use and parking areas the following comments apply; 1. This comment was not addressed. The dimension is shown to the bollard not the vehicle parking space. Show the required 2' setback from the PAAL to the wall. 2. 2-06.4.9.H.5 - Provide a PAAL width dimension for the PAAL located to the southwest of the eastern most building between the proposed wall and the vehicle parking spaces. Per UDC Article 7.4.6.F.2.b Access lanes and PAALs must be setback at least two feet from a wall, screen, or other obstruction over six inches. That said show the 2' setback to the wall and the required 24' PAAL. 3. This comment was not addressed, demonstrate on the plan how access is provided from the accessible vehicle parking spaces shown on the plan to the accessible route to the building. 2-06.4.9.H.5.a - Provide a detail for the proposed and/or existing accessible ramps shown on the plan that demonstrates how the requirements of IBC Chapter 11 and ICC A117.1-2009 are met. 4. 2-06.4.9.R Near the southwest corner of the eastern most building there is a sidewalk dimensioned at 3'-0" this sidewalk is required to be 4'-0" per TSM 7-01.4.3.A. Once the above comments are addressed Zoning is willing to provide and over-the-counter review. If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package |
| 04/11/2016 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Completed | |
| 04/12/2016 | JOE LINVILLE | LANDSCAPE | REVIEW | Reqs Change | 1) A change to the screening will necessitate a new review for the affected landscape borders. UDC 7.6.4.C.2 Note the applicable landscape border requirements (based on the zoning standards in effect at the time the existing development received zoning/landscape approval) for the site. If the wall construction requires modification or removal of the landscaping, document the changes on a revised landscape plan. AM 2-10.2.0 |
| 04/13/2016 | LOREN MAKUS | ENGINEERING | REVIEW | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 04/19/2016 | RBENT1 | APPROVAL SHELF | Completed |
| 04/19/2016 | RBENT1 | OUT TO CUSTOMER | Completed |
| 04/19/2016 | RBENT1 | REJECT SHELF | Completed |