Permit Number: DP16-0001
Parcel: 13809007G

Review Status: Active

Review Details: SITE and/or GRADING

Permit Number - DP16-0001
Review Name: SITE and/or GRADING
Review Status: Active
Review Date Reviewer's Name Type of Review Description Status Comments
01/08/2016 MICHAEL ST. PAUL ZONING REVIEW Reqs Change CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Michael St Paul
Planning Technician

PROJECT: DP16-0001
432 West Valencia Road
Expansion of Food Service (C-1)

TRANSMITTAL DATE: January 8, 2016

DUE DATE: February 4, 2016

1) COMMENT: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Unified Development Code, The Administrative and Technical Manuals were addressed.

2-06.4.0 CONTENT REQUIREMENTS

2-06.4.1 - The name, mailing and email addresses, and phone number of the primary property owner of the site, the developer of the project, registrant(s), and other person(s), firm(s), or organization(s) that prepared the development package documents shall be provided on the right half of the cover sheet. The applicable registration or license number shall be provided if prepared by or with the assistance of a registered professional, such as a surveyor, architect, landscape architect, or engineer. All sealing shall be consistent with Arizona Board of Technical Registration guidelines.

2) COMMENT: Provide the email addresses for the owners.

2-06.4.3 - The administrative street address and relevant case numbers (development package document, subdivision, rezoning, board of adjustment, DDO, MDR, DSMR, overlay, etc.) shall be provided adjacent to the title block on each sheet.

3) COMMENT: Provide the development package case number (DP16-0001) on the lower-right corner of each sheet adjacent to the title block.

2-06.4.7.A.4 - Identify the existing and proposed use of the property as classified per the UDC. List all UDC sections applicable to the proposed uses.

4) COMMENT: The existing and proposed use is Food Service (UDC Section 4.7.20 and Table 4.8-4, with Use Specific Standards 4.9.4.M.1 & .5 and 4.9.13.O). Provide this additional information on the coversheet.


If you have any questions about this transmittal, please call Michael St. Paul, (520) 837-4959.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package site plan and any requested documents.
01/15/2016 MARTIN BROWN FIRE REVIEW Reqs Change Unable to determine from plans if building contains fire sprinklers. If it does not, and the addition pushes the occupant load over 100 or the square footage to over 5000 sq. ft., fire sprinklers would be required. Please clarify.
01/22/2016 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Reqs Change Revise the site drawing to include the following information:
a. The location of water lines, and fire hydrants.
b. The point of connection to the existing public sewer.
c. Any existing or proposed utility easements
d. The first floor elevation for the building addition
Reference: City of Tucson Administrative Manual No. 2-06.0.0, Section 4.8 and Section 107.2.13, IBC 2012.
01/25/2016 ANDREW CONNOR LANDSCAPE REVIEW Approv-Cond Ensure that all Zoning and Engineering comments and concerns are addressed prior to landscape approval signature.
01/25/2016 ANDREW CONNOR NPPO REVIEW Approved
01/26/2016 LOREN MAKUS ENGINEERING REVIEW Approved
01/27/2016 MICHAEL ST. PAUL H/C SITE REVIEW Approved
01/27/2016 MSTPAUL1 ADA REVIEW Passed
02/04/2016 ZELIN CANCHOLA COT NON-DSD TRAFFIC Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
01/06/2016 ANY REJECT SHELF RECEIVED