Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: DP15-0219
Parcel: 136089850

Review Status: Completed

Review Details: SITE and/or GRADING

Permit Number - DP15-0219
Review Name: SITE and/or GRADING
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/08/2016 PAUL BAUGHMAN ENGINEERING REVIEW Reqs Change DATE: January 13, 2016
DUE DATE: January 14, 2016
SUBJECT: New SFR
TO: Daniel Campa
LOCATION: 9615 E 31st Street
REVIEWERS: Paul Baughman, PE, CFM
ACTIVITY: DP15-0219
SUMMARY: Engineering Division of Planning and Development Services Department has received and reviewed the proposed Development Plan Package. The following items need to be addressed:
1) Per AM 2-06.4.3 please show the relevant case number DP15-216 on the plans set.
2) Per TSM 10-01.4.1A1a and b1 please show sidewalk adjacent to street to be a minimum of 5 feet in width.
3) Per AM 2-06.4.1 please add the email address of the owner and engineer and the phone number of the owner.
4) Per AM 2-06.4.7A7 please provide the subdivision case number (S04-167) of which this property is a part in the lower right corner of each sheet.
5) Per AM 2-06.4.7B1 please add the following note to the plans "The developer, any successors and assigns, will hold the City of Tucson, its officers, employees, and agents harmless from any and all claims for damages related to the use of this development as shown hereon, now and in the future, by reason of flooding, flowage, erosion, or damage caused by water, whether surface flood or rainfall."
6) Per AM 2-06.4.7B3 please add the following note on the plans, "Drainage will remain in its natural state and will not be altered, disturbed, or obstructed other than as shown on this site plan."
7) Per AM 2-06.4.8B please provide recordation information for the electric easement to the east of the property limits.
8) Per AM 2-06.4.8B and AM 2-06.4.9H4 please provide dimensioning between the sidewalks, curb, right-of-way limits, paving, width of paving and recording information for the right of way.
9) Per AM 2-06.4.8D please provide the size of the water and sewer lines as well as manhole information such as invert and rim elevations.
If you have any comments questions or wish to discuss new information, please call or email me at 520-837-5007 or paul.baughman@tucsonaz.gov
01/13/2016 ANDREW CONNOR NPPO REVIEW Reqs Change According to final plat Case # S04-167 a NATIVE PLANT PRESERVATION PLAN is required

7.7. NATIVE PLANT PRESERVATION

7.7.3. APPLICABILITY

Single-family residential development on lots recorded after March 24, 1997.

Submit NPP plan.
01/13/2016 ANDREW CONNOR LANDSCAPE REVIEW Reqs Change According to final plat Case # S04-167 a NATIVE PLANT PRESERVATION PLAN is required

7.7. NATIVE PLANT PRESERVATION

7.7.3. APPLICABILITY

Single-family residential development on lots recorded after March 24, 1997.

Submit NPP plan.
01/14/2016 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Reqs Change Revise the site drawing to include the following information:
a. The location any fire hydrants.
b. The locations, pipe diameter, invert, and rim elevation of the upstream and downstream manholes along with the Pima County Wastewater Management Department (PCWMD) reference numbers.
Reference: City of Tucson Administrative Manual No. 2-06.0.0, Section 4.8 and Section 107.2.13, IBC 2012.
01/20/2016 EGALLET1 ADA REVIEW Needs Review
01/20/2016 EGALLET1 H/C SITE REVIEW Needs Review
12/17/2015 KEN BROUILLETTE FIRE REVIEW Approved
12/29/2015 DAVID RIVERA ZONING REVIEW Denied CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: David Rivera
Principal Planner

PROJECT: DP15-0217
9608 E 31st Street
New SFR

TRANSMITTAL DATE: December 29, 2015


COMMENTS:

01. Include the lot coverage calculations.

Revise building setback note number 3 to include the that the setbacks are based on the greater of 20 feet or 1.5 times the height from the front street property line and the greater of 6 feet or 2/3 the height for interior setbacks.

02. List the height of the proposed building.

03. Include dimensioned building elevations to verify heights and check for correct building setbacks.


If you have any questions about this transmittal, please call David Rivera, (520) 791-5608.


RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised Site Plan and Elevation Drawings

Final Status

Task End Date Reviewer's Name Type of Review Description
01/20/2016 EGALLET1 OUT TO CUSTOMER Completed