Permit Number: DP15-0198
Parcel: 11713157A

Address:
235 S CHURCH AV

Review Status: Completed

Review Details: DEV PKG - RESUBMITTAL

Permit Number - DP15-0198
Review Name: DEV PKG - RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/12/2017 LOREN MAKUS ENGINEERING REVIEW Approved
01/17/2017 ANDREW CONNOR LANDSCAPE REVIEW Reqs Change UNIFIED DEVELOPMENT CODE
4.1 Identification and Descriptive Data
A. All improvements and site information, such as adjacent rights-of-way and property lines, shown on the landscape plan will be identical in size and location to those shown on the base plan (site plan or tentative plat). Should amendments be required to the base plan through the review process, the same amendments will be made to the landscape plan which will then be resubmitted along with the base plan.
This project was processed through an IID application review and approval. Contact Carolyn Laurie to verify if the revised DP must go back for an IID review and re-approval.
Ensure that Zoning comments are addressed.
Additional comments may apply.
01/17/2017 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Reqs Change The rim elevation of the next upstream public sanitary cleanout (2384.48) is more than 12" below the first floor elevation (2386.6'). The installation of a backwater valve is not allowed for building drains serving fixtures located on floors more than 12" above the next upstream manhole or cleanout. Reference: Section 715.1, IPC 2012, as amended by the City of Tucson.
01/23/2017 GARY WITTWER COT NON-DSD TDOT Approved I have no comments on this project.

>>> DSD_CDRC 12/21/2016 9:56 AM >>>

This is an electronic distribution for the 4th review of a CDRC Development Package. The paper copies of the review documents are available in the plans room.




The applicable case number is:



CDRC Development Plan: DP15-0198

Address: 235 South Church Ave

Proposed Use: MultiFamily Dwelling

Due Date: January 19, 2016

Electronic Documents are attached to this email.
01/24/2017 KLEE1 ZONING-DECISION LETTER REVIEW Reqs Change This review has been completed and resubmittal is required. Please resubmit the following items:
1) Two rolled sets of the plans
2) All approved documents submitted previously
3) A disk containing all items submitted
4) All items requested by review staff
5) All items needed to approve these plans
12/19/2016 ARUIZ1 START PLANS SUBMITTED Completed
12/21/2016 CLAURIE1 DESIGN PROFESSIONAL REVIEW Denied Provide additional information assoicated with new wall alignment and site access.
12/28/2016 DAVID RIVERA ZONING REVIEW Reqs Change CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: David Rivera for Steve Shields - Principal Planner
PDSD Zoning Review Section

PROJECT: DP for the Marist On Cathedral Square - Marist College
Development Package (1st Review) Revision Set
DP15-0198

TRANSMITTAL DATE: December 28, 2016
DUE DATE: January 19, 2016

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

The following comments are related to the proposed revisions and changes to the DP plan sheets.

SECTION 2-06.0.0: DEVELOPMENT PACKAGE (TENTATIVE PLATS AND SITE PLANS)
Section

2-06.3.12 - An index of sheets in the development package shall be provided on the first sheet.

1. COMMENT: The sheet index on the cover sheet or the sheet names in the title block for sheets 4 and 5 must be revised. The sheet index lists sheet 4 as the "Utilities and Easement Plan" and sheet 5 as the "Grading and Hydrology Plan". Sheet 4 and sheet 5 are actually reversed in the plan set and the "Grading and Drainage plan should be renamed to match the index or visa versa. Revise as required.


2-06.4.7.A.8.a - Floor area for each building;

2. COMMENT: Clarify why there is such a difference in the building square footage? If the building is being expanded draw and label the building expansion and include the square footage and height of the new expansion.


2-06.4.9.L - All proposed easements (utility, sewer, drainage, access, etc.) are to be dimensioned and labeled as to their purposes and whether they will be public or private. The easements may have to be recorded and the recordation information added to the development package prior to approval.

3. COMMENT: On sheet 5 "Utilities and Easement Plan", two (2) new easements are proposed. One is a Pedestrian access easement and a new electric easement along the west boundary south of the driveway. Both easements must be recorded and the recordation information must be listed on the DP plan sheet prior to final approval of the DP.


4. COMMENT: This project was processed through an IID application review and approval. Contact Carolyn Laurie to verify if the revised DP must go back for an IID review and re-approval.


If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package

Final Status

Task End Date Reviewer's Name Type of Review Description
02/10/2017 PIBARRA1 OUT TO CUSTOMER Completed