Permit Number: DP15-0177
Parcel: 107150050

Address:
2745 N 1ST AV

Review Status: Active

Review Details: SITE and/or GRADING

Permit Number - DP15-0177
Review Name: SITE and/or GRADING
Review Status: Active
Review Date Reviewer's Name Type of Review Description Status Comments
10/14/2015 KEN BROUILLETTE FIRE REVIEW Approved
10/14/2015 ANDREW CONNOR NPPO REVIEW Approved
10/14/2015 ANDREW CONNOR LANDSCAPE REVIEW Approved
10/14/2015 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Completed
10/14/2015 STEVE SHIELDS ZONING REVIEW Approved
10/14/2015 SSHIELD1 ADA REVIEW Passed
10/14/2015 JASON GREEN ENGINEERING REVIEW Approved
10/14/2015 SSHIELD1 H/C SITE REVIEW Reqs Change CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Steve Shields
Lead Planner

PROJECT: Kent'S Tools
Accessibility Review - On Site Only
Development Package (1st Review)
DP15-0177

TRANSMITTAL DATE: October 14, 2015

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

Provide an accessible route from the accessible parking space to the accessible route at the building and to all accessible entrances of the building.

Insure and provide a note to that effect, that all accessible route slopes are to comply with ICC A117.1, Section 403.3; 5% maximum running slopes and 2% maximum cross slopes.

Provide a large scale detail of the accessible parking space showing all accessible requirements such as dimensions, markings, grade slopes, accessible parking aisle, signage, van accessible space and access to the accessible route.

Provide running slope directional arrows, running slope percentages, cross slope directional arrows and cross slope percentages for all surfaces along the required accessible route from the proposed building entrance to the sidewalk located in the right-of-way per ICC A117.1-2009 403.3 and IBC 107.2.1