Permit Review Detail
Review Status: Completed
Review Details: RESUB - SITE and/or GRADING
Permit Number - DP15-0153
Review Name: RESUB - SITE and/or GRADING
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/05/2015 | PAUL BAUGHMAN | ENGINEERING | REVIEW | Approved | |
| 11/23/2015 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Reqs Change | 1. No changes made to utility drawing (6 of 9). [Initial comment: The rim elevation of the next upstream sanitary cleanout (2523.1') is less than 12" below the first floor elevations (2523.1' and 2523.8'). Provide a note on the plans requiring the installation of a backwater valve when future plumbing activities take place. Reference: Section 715.1, IPC 2012, as amended by the City of Tucson.] 2. No changes made to utility drawing (6 of 9). [Initial comment: Relocate the cleanout for the building sewer from Pad I to outside of the public sewer easement. Reference: Standard Detail RWRD 401 (HCS), 12/2012.] 3. No changes made to utility drawing (6 of 9). [Initial comment: Note that the 4" private building sewer connections to the existing 6" public sewer must be made with wye-fittings and cannot be made using tapping saddles.] 4. No changes made to utility drawing (6 of 9). [Initial comment: Show the limits of the public sewer easements.] |
| 11/24/2015 | STEVE SHIELDS | ZONING | REVIEW | Approv-Cond | Revise the crosswalk to the east of the proposed buildings to match sheets two (2) and three (3) on all the other sheets depicting the crosswalks. Remove the "floating" truncated on sheet three (3) of nine(9). Arrange for me to make the final approval on the counter. |
| 11/27/2015 | ANDREW CONNOR | LANDSCAPE | REVIEW | Approved |