Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Completed
Review Details: SITE and/or GRADING
Permit Number - DP15-0129
Review Name: SITE and/or GRADING
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/01/2015 | LOREN MAKUS | ENGINEERING | REVIEW | Reqs Change | 1. Show how this development ties into the existing development. Since the entrance to the new parking area seems to obliterate three existing parking spaces, provide a revised development package showing the whole site with the proposed development. 2. The development package shows paving onto adjacent parcels. Provide signed and notarized letters of permission or recordation data for an easement. |
| 09/04/2015 | ANDREW CONNOR | NPPO | REVIEW | Approved | Provide NPPO Plan or acceptable documentation, which clearly indicates that the project will not impact Protected Native Plants. Such documentation includes photographs of the site taken from all sides of the property. |
| 09/04/2015 | ANDREW CONNOR | LANDSCAPE | REVIEW | Reqs Change | ARTICLE 7: DEVELOPMENT STANDARDS The standards in this Section 7.6.4 apply to all developments that provide more than four motor vehicle parking spaces. A separate Landscape plan must be submitted for review. LANDSCAPING AND SCREENING Within a vehicular use area, one canopy tree is required for each four motor vehicle parking spaces or fraction thereof. The canopy trees must be evenly distributed throughout the vehicular use area. Every parking space must be located within 40 feet of the trunk of a canopy tree (as measured from the center of the tree trunk). ADMINISTRATIVE MANUAL SECTION 2-10.0.0: LANDSCAPE PLAN REQUIREMENTS A detailed landscape plan is required. In accordance with Section 2-11.0.0, Landscape Plan Requirements. ARTICLE 7: DEVELOPMENT STANDARDS Identification and Descriptive Data All improvements and site information, such as adjacent rights-of-way and property lines, shown on the landscape plan will be identical in size and location to those shown on the base plan (site plan or tentative plat). Should amendments be required to the base plan through the review process, the same amendments will be made to the landscape plan which will then be resubmitted along with the base plan. The landscape plan will contain the following identification in the lower right corner of each sheet: Any relevant case number for reviews or modifications that affect the site Planting Plan Vegetation Plan and Schedules Ultimate size of plants indicated by the spread of canopy, circumference of shrubs, or spread of ground cover; Both the proper and common name of each type of plant material. Material and areas of inert ground cover. Square footage of the vehicular use area; number of parking spaces, including the required and provided parking space calculations; and the calculation of the required number of canopy trees. Maintenance Schedule Pruning schedules to show that plant material will maintain pedestrian and vehicular clearances or that the material will establish opaque hedge screens, if required; Replacement criteria, should plant material not survive; Replacement or upkeep maintenance schedules for inert ground cover materials; Upkeep maintenance schedules for exterior hardscape materials; and, Maintenance and replacement schedules for irrigation systems Grading Information Grade changes across the site indicated by one-foot interval contour lines or by spot elevations; Percent slope across the site and the direction of the slope of paved areas; Existing grades on adjacent rights-of-way and adjacent sites. If an adjacent right-of- The methods by which water harvesting or storm water runoff is used to benefit the planting areas on the site. Irrigation Plan Type of water conserving irrigation systems proposed and differentiation between systems for the different water use zones on the site; Source of irrigation water; Indicate potable or reclaimed water use. Reclaimed water system specifications, if used; System specifications and system design and layout (Section 4-01.4.2, Irrigation Standards, of the Technical Standards Manual); Extent of supplementary irrigation in each planting area, provided by water harvesting methods; Point of drainage off roof areas, amount of flow, and disposition of flow; The length of irrigation duration (e.g., for native plat material, automatic drip for two years or until established). Ensure that all Zoning and Engineering comments and concerns are addressed. Additional comments may apply |
| 09/08/2015 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Completed | |
| 09/08/2015 | MICHAEL ST. PAUL | ZONING | REVIEW | Reqs Change | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Michael St Paul Planning Technician PROJECT: DP15-0129 1955 West Grant Road Parking lot addition to office complex TRANSMITTAL DATE: September 8, 2015 DUE DATE: September 8, 2015 Provide a Development Package in compliance with the Administrative Manual for the City of Tucson Section 2-06. Provide the parking-area-access-lane (PAAL) dimension on the site plan. The minimum PAAL width is twenty-four (24) feet for two-way traffic aisle with ninety (90) degree parking (UDC Section 7.4.6.D.1 and Figure 7.4.6-A). A back-up spur (See Figure 7.4.6-B) must be setback three feet to any obstruction or property line (UDC Section 7.4.6.B.4.c). The back-up spur must be a minimum of three (3) feet in depth and have three foot radii (UDC Section 7.4.6.B.4.b). The previous split for parcel 115-20-261C shall be required to be a subdivision. A subdivision is required for "Any property whose boundaries are fixed by a recorded plat, which is divided into more than two parts" (UDC Section 11.4.20). : See Administrative Manual for the City of Tucson Section 2-07. Also see UDC Section 8.4 for subdivisions. |
| 09/09/2015 | KEN BROUILLETTE | FIRE | REVIEW | Approved | |
| 09/10/2015 | BVIESTE1 | ADA | REVIEW | Passed | |
| 09/10/2015 | MICHAEL ST. PAUL | H/C SITE | REVIEW | Passed |