Permit Number: DP15-0114
Parcel: 12301017F

Address:
1777 N POTTER PL

Review Status: Completed

Review Details: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW

Permit Number - DP15-0114
Review Name: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/25/2015 AROMERO4 START PLANS SUBMITTED Completed
09/28/2015 STEVE SHIELDS ZONING REVIEW Approved
10/09/2015 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Completed
10/09/2015 ED ABRIGO PIMA COUNTY ASSESSOR Approved Office of the Pima County Assessor
115 N. Church Ave.
Tucson, Arizona 85701

BILL STAPLES
ASSESSOR

TO: CITY OF TUCSON
PLANNING & DEVELOPMENT SERVICES DEPARTMENT


FROM: Suzanne Gilpin
GIS Cartographer
Pima County Assessor's Office
(520)724-4387


DATE: October 12, 2015


RE: Assessor's Review and Comments Regarding DP15-0114 CASA SETON PLACE-Tentative Plat
* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *

X Plat meets Assessor's Office requirements.
_____ Plat does not meet Assessor's Office requirements.

COMMENTS:



NOTE: There must be bearings and dimensions for the perimeter and all lot lines and all common areas on Final Plat.
10/09/2015 ELIZABETH LEIBOLD ENGINEERING REVIEW Approv-Cond TO: Bill Carroll, P.E., Engineering and Environmental Consultants, Inc.
SUBJECT: Development Package Engineering 3rd Review submittal
PROJECT: Casa Seton Tentative Plat Development Package Engineering Review
LOCATION: 1777 N POTTER P, 123-01-017F, T14S R14E Sec5, Ward 6
IMPACT FEE AREA: Central
FEMA PANEL: 2277L, Zone X-Unshaded
WATERSHED: Flowing Wells Wash Watershed (a non-designated basin management area)
REVIEWER: Elizabeth Leibold P.E.
ACTIVITY NUMBER: DP15-0114
SUMMARY: The 2nd resubmittal of this Development Package includes the Tentative Plat, with conceptual grading a new subdivision Casa Seton, which was received and reviewed by Planning & Development Services Department Engineering Division for project feasibility for Tentative Plat review purposes only. Discussion of soils report with engineer from EOR's office occurred end of August. Development Services Department Engineering Division recommends conditional approval of this Development Package and requests the remaining minor comments be addressed.
BASE PLAN / SITE PLAN / MASTER COVER SHEETS/ GENERAL NOTES:
1) Admin Man Sec.2-06.4.8.G, 4.8.D: address the remaining legend comments:
a) See Soils Comment below. Also, clarify existing condition flow arrows on planviews - these arrows appear to be not printing out at a very small scale. Add flow arrow symbol to legend.
b) Add symbol to legend for existing well as it appears to be labeled in the legend but symbol was not legible.
DRAINAGE REPORT COMMENTS:
2) UDC Sec.7.14.1&4, Tech Man Sec.4-04.2.2, 2.3.1: Address the remaining Drainage Report comments:
a) In-lieu of retention, add discussion in drainage report that compares the proposed 20% runoff reduction to the in-lieu detention option of: the difference in volume between the developed and existing 2-yr runoff volumes or the difference in peak discharges with the difference in volume and/or peak discharges between the developed and existing 5-yr runoff volumes. Explain how minimum requirement is met.
b) Admin Man Sec.2-06.4.9.N, Tech Man Sec.4-04.2.3.1.6.A.4: Clarify on sheet C-2 all sub-watershed flowrates. Provide clarification in drainage report for pre- and post development conditions using cross sections with velocity, depth, width, and flowrate comparison.
GRADING, PAVING, DETAIL SHEET COMMENTS:
3) Admin Man Sec.2-06.4.9.M.1,2-06.4.9.W,Tech Man Secs.2-01.4.1.C, 4-04.2.3.1.5.C, 8-01.5.2.G: On sheet 3, address the remaining Typical Lot Grading detail H comments (see redlines):
a) Clarify setback exception for lots 7 & 8.
b) Consider clarifying that "A" lot detail is for all other lots other than lot 7.
c) Correct "weep holes" nomenclature for wall openings since there are only screen walls proposed.
SOILS/GEOTECHNICAL REPORT / UTILITIES / EASEMENTS COMMENTS:
4) Admin Man Sec.2-06.4.8.B, 2-06.4.9.L, Tech Man Secs.4-04.2.3.1.6.A.4.d, 4-03.2.2, 2-01, 4-03.III.3.5.1.3.a: Address the remaining comments:
a) On Tentative Plat planview, show full extent of the existing sewerline and explain in response letter where the end of the existing sewerline terminates and what parcel(s) it serves south of northwest corner of project site. Add a note to Tentative Plat that no sewer easement was found for the existing sewerline along northwest property boundary.
b) Label 15-ft setback per geotechnical engineering evaluation addendum No.2. Otherwise, provide revised soils report or addendum for setback distance recommendations from high water line of proposed basin to proposed future houses.
c) Revise General Note 24 on sheet 1 to include statement that any onsite well shall be exposed and remediated by applicable agencies. Provide any soil recommendations for area where pool was removed / verify soil properly prepared for compaction. This may be addressed at grading improvement plan review stage.
Grading-related comments will be provided under improvement plan review package DP15-0175. Return redline set with resubmittal. For resubmittal, provide revised development package including revised Tentative Plat sheets, redlines, revised drainage report, comprehensive response letter, copy of title report, and if needed, revised soils report or addendum and any other documents. A meeting is required with EOR to assure remaining comments are addressed. If you have questions, call me at 837-4934.
Elizabeth Leibold, P.E., CPM, CFM
Civil Engineer
Engineering Division
Planning & Development Services Dept
10/09/2015 JENNIFER STEPHENS PIMA COUNTY ADDRESSING Approved MICHELENE NOWAK

ADDRESSING REVIEW

PH #: 721-9512

TO:

CITY PLANNING


FROM:

MICHELENE NOWAK, ADDRESSING REVIEW


SUBJECT:

DP15-0114 CASA SETON LOTS 1-11/TENTATIVE PLAT 3RD REVIEW


DATE:

October 9, 2015




The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project.



On Preservation Plan, Landscape Plan, Irrigation Plan label Detention Base as C.A. “B”



1.) Submit a 24 x 36 Reverse Reading Double Matte Photo Mylar of approved Final Plat to City Planning



***PIMA COUNTY ADDRESSING MUST RECEIVE A COPY OF THE RECORDED FINAL PLAT PRIOR TO THE ASSIGNMENT OF ANY ADDRESSES. PLEASE COORDINATE THE DELIVERY AND RECORDATION OF THE MYLAR WITH THE CITY OF TUCSON PLANNING***



2.) All addresses will need to be displayed per Pima County Address Standards at the time of final inspection.





***The Pima County Addressing Section can use digital CAD drawing files.

These CAD files can be e-mailed to: CADsubmittals@pima.gov

The digital CAD drawing files expedite the addressing and permitting processes when we are able to insert this digital data into the County’s Geographic Information System. Your support is greatly appreciated.***
10/14/2015 BVIESTE1 ZONING-DECISION LETTER REVIEW Approv-Cond

Final Status

Task End Date Reviewer's Name Type of Review Description
11/17/2015 KROBLES1 REJECT SHELF Completed