Permit Review Detail
Review Status: Completed
Review Details: TENTATIVE PLAT REVIEW
Permit Number - DP15-0114
Review Name: TENTATIVE PLAT REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/27/2015 | AROMERO4 | START | PLANS SUBMITTED | Completed | |
| 07/29/2015 | PGEHLEN1 | UTILITIES | SOUTHWEST GAS | Approved | See additional documents in PRO July 28, 2015 City of Tucson CDRC Attn: Patricia Gehlen, Manager 201 N. Stone Avenue Tucson, AZ 85701 RE: SWG Plan Review for Casa Seton - Tentative Plat CDRC: DP15-0114 Dear Ms. Gehlen: Southwest Gas Corporation (SWG) has no objection to the development of the above-mentioned project. Existing natural gas facilities are located in adjacent rights-of-way to the area of development and may be utilized for extension to the proposed development; specifically, an existing 2” gas main is located within the right-of-way of Elm Street If additional public utility easements and/or common areas are to be granted, SWG respectfully requests that dedication verbiage be added to the project general notes, including dedication notes that document the following: Utility easements allow for the installation and maintenance of both public and private utilities. Private common areas allow for the installation and maintenance of private underground utilities Blue Stake and potholing are suggested for best accuracy when locating SWG facilities. Please be aware that SWG requires a minimum one-foot separation from distribution facilities and any proposed structures and two-foot separation from high pressure gas facilities. SWG requests the contractor use caution when working in the vicinity of gas facilities and protect and support gas facilities per Blue Stake requirements. SWG also requests that no trees be planted within close proximity to gas facilities due to root intrusion; therefore, SWG requires all tree placements have a minimum eight-foot clearance from the tree center line to existing or proposed gas facilities. Shrubs and bushes may be planted within the eight-foot clearance zone. All information is provided for reference use only. Please note that it is the responsibility of excavators or those developers planning excavation to verify actual field conditions in advance of construction so that requests for gas service or any potential issues can be addressed in a timely manner. Please include SWG in all future plat and development plan submittals of this project. If you have any questions or require any additional information, please contact me at (520) 794-6218 or TUCSWGDevReview@swgas.com. Sincerely, Arthur Lason Engineering Technician Southern Arizona Division Enc: SWG Contact Information (pdf) |
| 08/03/2015 | TOM MARTINEZ | OTHER AGENCIES | AZ DEPT TRANSPORTATION | Approved | Regional Traffic Engineering has no comments on this submittal and supports its acceptance. Thank you. -------------------------------------------------------------------------------- |
| 08/04/2015 | ED ABRIGO | PIMA COUNTY | ASSESSOR | Reqs Change | Office of the Pima County Assessor 115 N. Church Ave. Tucson, Arizona 85701 BILL STAPLES ASSESSOR TO: City of Tucson Development Services FROM: Suzanne Gilpin GIS Cartographer Pima County Assessor's Office 520)724-4387 DATE: August 4, 2015 RE: Assessor's Review and Comments Regarding Tentative Plat- DP15-0114/CASA SETON TENTATIVE PLAT/AKA POTTER PLACE * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * Plat meets Assessor's Office requirements. _X____ Plat does not meet Assessor's Office requirements. COMMENTS: " The owner shown on the Tentative Plat is incorrect. The current owner of parcel 123-01-171E, 123-01-017F and 123-05-372B (of which 123-05-372B was omitted from application) POTTER PLACE LLC is the correct ownership. NOTE: THE ASSESSOR'S CURRENT INVOLVEMENT IN PROCESSING ITS MANUAL MAPS TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. THANK YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED. |
| 08/04/2015 | PGEHLEN1 | POLICE | REVIEW | Approved | I have no issues with this proposal. CSO Becky Noel #37968 Tucson Police Dept. 1100 S. Alvernon Tucson, AZ 85711 520-837-7428 >>> DSD_CDRC 7/27/2015 2:59 PM >>> Dear Reviewers: This is an electronic distribution for a CDRC Tentative Plat review. If you normally receive paper copies of the review documents, you will receive them soon. The applicable case numbers are: CDRC Development Plan: DP15-0114 Existing and Proposed Zoning: R-2 Proposed Use: Residential Subdivision Due Date: August 20, 2015 |
| 08/10/2015 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Steve Shields Lead Planner PROJECT: Casa Seton Development Package (1st Review) DP15-0114 TRANSMITTAL DATE: August 21, 2015 DUE DATE: August 21, 2015 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM). The review comments include the actual standard first with the applicable Administrative Manual section number and the following paragraph is the actual comment related to the specific item that must be addressed. If you need to review the sections listed below click on the link or copy it in the address bar of your internet program. http://www.amlegal.com/nxt/gateway.dll/Arizona/tucson_az_udc/administrativemanual?f=templates$fn=default.htm$3.0$vid=amlegal:tucson_udc_az This link will take you directly to the section used for the standards review. The UDC & TSM requirements are in the Unified Development Code and can be viewed at the same web link as above Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is , 2016. SECTION 2-06.0.0: DEVELOPMENT PACKAGE (TENTATIVE PLATS AND SITE PLANS) Section 2-06.1.0 GENERAL 2-06.2.0 APPLICATION SUBMITTAL REQUIREMENTS 2-06.3.0 FORMAT REQUIREMENTS 2-06.4.0 CONTENT REQUIREMENTS 2-06.5.0 FLEXIBLE LOT DEVELOPMENT (FLD) - ADDITIONAL REQUIREMENTS 2-06.1.0 GENERAL 2-06.1.1 PURPOSE This standard has been prepared for the purpose of informing applicants of the submittal and review requirements for development package documents to assure proper and adequate information is presented in a consistent manner, thereby providing the basis for an efficient and timely review. The development package documents are prepared in support of applications for building permits and related reviews. The information that is requested establishes the basis upon which the project will be approved and could affect what is required of the property in the future, should there be a proposal for expansion or for a different use of the property. This standard does not waive any applicable city regulations or codes. 2-06.1.2 APPICABILITY This standard shall be used for all site plans and tentative plats submitted to PDSD for review. 2-06.2.1 APPLICATION SUBMITTAL REQUIREMENTS Development Package applications are available from PDSD. Completed applications and accompanying materials shall be submitted to PDSD. Incomplete or inaccurate applications will not be accepted, nor will any application in which the pre-application conference or neighborhood meeting requirements have not been met. The types of documents and the specific number of copies required of each of the documents are on the PDSD website or may be obtained from PDSD. Resubmittals of development packages require a comment response letter that details how all previous comments have been addressed. Provide the same number of copies of the comment response letter as plans provided. The following documents and information shall be submitted upon application: 2-06.2.1 Application Form A completed application signed by the property owner or authorized designee; 2-06.2.2 Development Package A development package must be prepared to the format and content requirements described herein; 2-06.2.3 Related Reviews In addition to the plan process, a project may require review for other types of plans and documents. The applications for those processes are submitted to the appropriate department for review and approval. These related reviews can be applied for so that review can occur concurrently with the development package application. However, it must be understood that, should the related application be approved subject to conditions or denied, this may affect the; 2-06.2.4 Concurrent Reviews The development package is designed to allow for concurrent review of any site related reviews. Concurrent review means that all plans and documents needed for the review are submitted as one package. Examples of site related reviews include but are not limited to: site plans, landscape plans, NPPO plans, water harvesting plans, grading plans, SWPPP plans, floodplain use permits, and overlay reviews. Separate applications are often required for the different site related reviews even if the plans are submitted concurrently; and, 2-06.2.5 Fees Fees in accordance with Section 4-01.0.0, Development Review Fee Schedule. CONTENT REQUIREMENTS 2-06.4.2 - The title block shall include the following information and be provided on each sheet: 2-06.4.3 - The administrative street address and relevant case numbers (development package document, subdivision, rezoning, board of adjustment, DDO, MDR, DSMR, overlay, etc.) shall be provided adjacent to the title block on each sheet. 1. COMMENT: Provide the development package case number, DP15-0114, adjacent to the title block on each sheet. 2-06.4.7 - General Notes The following general notes are required. Additional notes specific to each plan are required where applicable. 2-06.4.7.A - Zoning and Land Use Notes 2-06.4.7.A.4 - Identify the existing and proposed use of the property as classified per the UDC. List all UDC sections applicable to the proposed uses. 1) COMMENT: Add the following to General Note 4, "SUBJECT TO USE SPECIFIC STANDARDS 4.9.7.B.6, .9, & .10". 2-06.4.7.A.6.a - List additional applications and overlays, by case number (if applicable), in lower right corner of each sheet. As a general note provide the type of application processed or overlays applicable, a statement that the project meets the criteria/conditions of the additional application or overlay, the case number, date of approval, what was approved, and the conditions of approval, if any. 2) COMMENT: As a Technical Standards Modification Request (TSMR) will be required, provide the TSMR case number adjacent to the title block on each sheet. Also provide a general note stating the TSMR case number, date of approval, what was modified, and any conditions of approval. 2-06.4.7.A.7 - If the property is part of a subdivision plat that is being reviewed or has been recorded, provide the case number in the lower right corner of each sheet. As a general note, indicate whether the project is part of a Flexible Lot Development (FLD), condominium, or another similar type project. 3) COMMENT: If the final plat is submitted prior to approval of the tentative plat provide the final; plat case number adjacent to the title block on each sheet. 2-06.4.7.A.8 - For development package documents provide: 2-06.4.8 - Existing Site Conditions The following information shall be provided on the plan/plat drawing to indicate the existing conditions on site and within 50 feet of the site. On sites bounded by a street with a width of 50 feet or greater, the existing conditions across the street will be provided. 2-06.4.8.A - Provide site boundary/subdivision perimeter information, including bearing in degrees, minutes, and seconds, with basis for bearing noted, together with distances in feet, to hundredths of a foot, or other functional reference system. 4) COMMENT: It does not appear that the parcels shown south of the proposed development are shown correctly. Per the Assessor Office information lots 34, 35, 36, 37 and the east 30' of lot 38 have been combined. Show the parcels to the south correctly. 2-06.4.9 - Information on Proposed Development The following information on the proposed project shall be shown on the drawing or added as notes. 2-06.4.9.F - All existing zoning classifications on and adjacent to the project (including across any adjacent right-of-way) shall be indicated on the drawing with zoning boundaries clearly defined. If the property is being rezoned, use those boundaries and classifications. The basis for this requirement is that some zoning requirements on a project are based on the zoning classification of adjacent property. Also, in some instances, each zone has to be taken into consideration on property that is split by two or more zoning classifications, as each may have different requirements. 5) COMMENT: Provide the zoning for the parcels east of Potter Place. 6) COMMENT: The R-2 zoning shown for "LOT 34" is not correct and should be shown as R-1. 2-06.4.9.H - Proposed Traffic Circulation 2-06.4.9.H.2 - Show future and existing sight visibility triangles (SVTs). On a designated MS&R street, the sight visibility triangles are based on the MS&R cross-section. 7) COMMENT: Per TSM 10-01.5.1.A Lines of sight will not be obscured between 30 inches and six feet through a triangular area adjacent to a driveway, a PAAL, an alley, or a street, where such access ways intersect with another street in a T-configuration. The sight visibility triangle, or sight triangle, consists of three sides that are formed by two intersecting access ways and a line connecting the two. That said it appears that the "EXISTING ENTRY MONUMENT" shown on the plan encroaches into the SVT. 2-06.4.9.H.5.a - Show all motor vehicle off-street parking spaces provided, fully dimensioned. As a note, provide calculations on the number of spaces required (include the ratio used) and the number provided, including the number of spaces required and provided for the physically disabled. The drawing should indicate parking space locations for the physically disabled. A typical parking space detail shall be provided for both standard parking spaces and those for the physically disabled. For information on parking requirements for the physically disabled, refer to adopted building and accessibility codes of the City of Tucson. Design criteria for parking spaces and access are located in Section 7.4.6, Motor Vehicle Use Area Design Criteria, of the UDC. 8) COMMENT: The required number of visitor parking spaces is not correct. As you are proposing to provide visitor parking on each lot per UDC Section 7.4.6.B.2.a(1) the required number should be 11. 9) COMMENT: Per UDC Section 7.4.6.B.2.a(2) & (3) show the proposed visitor parking space on each lot. 2-06.4.9.H.7 - If streets are proposed, indicate if they are designed for on-street parking to accommodate visitor parking or if parking is provided in common parking areas. Visitor parking is to be evenly distributed and usable by all residents of the project. Extra parking on individual lots, such as tandem parking in driveways, does not count toward visitor parking, as it is not available to other property owners within the project. Design criteria for streets are located in Technical Standards Manual Section 10-01.0.0. Streets designed at the minimum width, without on-street parking, need clearance for access to all homes by life safety vehicles and, where no alleys are provided, by refuse collection vehicles. If motor vehicles are parked along streets that are not designed to allow for parking, life safety services will be inhibited and, in many situations, blocked. 10) COMMENT: Clearly show the proposed improvements to Potter Place from Elm Street north on the plan. Based on section G sheet 3 it does not appear that the proposed improvements will fit between the existing and proposed monument. 11) COMMENT: As the proposed modifications to Potter Place, private road, does not meet TSM Section 10 requirements, a TSMR will need to be processed and approved prior to approval of this development package. The TSMR will need to address street width, elimination of a sidewalk, etc. 2-06.4.9.R - Show on-site pedestrian circulation and refuge utilizing location and the design criteria in Section 7-01.0.0, Pedestrian Access, of the Technical Standards Manual. 12) COMMENT: Show the proposed pedestrian refuge area shown on section G sheet 3 on the plan sheet 2. This refuge area should run from the proposed sidewalk south to Elm Street. Zoning acknowledges that there are no sidewalks located along Elm Street therefore the refuge area should run to the property line along the north side of Elm Street. Provide construction details for this refuge area. 2-06.4.9.S - Show existing or proposed pedestrian circulation along abutting rights-of-way. Such sidewalks must comply with accessibility requirements for the physically disabled and the design criteria in Section 10-01.0.0, Street Technical Standards, of the Technical Standards Manual. 13) COMMENT: Demonstrate on the plan how accessibility will be addressed at the individual lot driveways. If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package |
| 08/12/2015 | PGEHLEN1 | UTILITIES | TUCSON ELECTRIC POWER | Approved | SUBJECT: CASA SETON TENTATIVE PLAT DP15-0114 Tucson Electric Power Co. (TEP) has reviewed and approved the Tentative Plat for Casa Seton Lots 1-11 submitted on July 27, 2015. TEP will prepare an electrical design on an Approved Tentative Plat. Please provide a copy of the Approved Tentative Plat and the subdivision AutoCAD file to mburke@tep.com. Easements for TEP facilities must be shown on the Final Plat before TEP can approve the plat. If you have any questions, please contact me at 520-917-8744. Thank you, Mary Burke Right of Way Agent Tucson Electric Power Co. Mail Stop HQE613 PO Box 711, Tucson, AZ 85702 Office - 520-917-8744 Cell - 520-401-9895 mburke@tep.com |
| 08/12/2015 | PGEHLEN1 | PIMA COUNTY | ADDRESSING | Reqs Change | 201 N. STONE AV, 1ST FL TUCSON, AZ 85701-1207 MICHELENE NOWAKADDRESSING REVIEW PH #: 724-9512 TO: CITY PLANNING FROM: MICHELENE NOWAK, ADDRESSING REVIEW SUBJECT: DP15-0114 CASA SETON LOTS 1-11/TENTATIVE PLAT 1ST REVIEW DATE: AUGUST 10, 2015 The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval: 1.Label Project# DP15-0114 on all Sheets.2.Correct Tax Parcels on Sheets 1, 2, 5, 6, 7 for adjacent property: on the north --#123-01-017D and on the east---#123-05-160A3.On Sheets 5, 6, 7 label Detention Basin as: Common Area “B”4.On Sheets 1, 2, 5, 6 correct Lot 3 to Lot 39 BK 7 M&P, PG 215.Place a STAR to show access for Lots 1, 7, 10, 11 on Sheet 26.Verify if Tax Parcel #123-05-372B (for access) is being resubdivided with this plat. If so, then the Title Block would need to be revised to include, a portion of Lot 35 Block O of Catalina Vista Mp Bk 7, Pg 21 . . . 7.Both private streets (Common Area “A”) will need to be named. The suffix will be “Place” or “Court”, since these are cul-de-sacs. Please e-mail proposed street name choices to: Addressing@pima.gov for review. |
| 08/17/2015 | PGEHLEN1 | TUCSON WATER NEW AREA DEVELOPMENT | REVIEW | Approved | See letter in PRO |
| 08/17/2015 | ZELIN CANCHOLA | COT NON-DSD | TRAFFIC | Approved | |
| 08/17/2015 | KBROUIL1 | COT NON-DSD | FIRE | Reqs Change | Please indicate the location of the nearest fire hydrant and if the proposed residences will have automatic fire sprinkler systems installed. Please indicate that no parking will be allowed on the private roads and that they will be posted per City Ordinances. |
| 08/18/2015 | PGEHLEN1 | COT NON-DSD | PARKS & RECREATION | Approved | No existing or proposed Tucson Parks and Recreation facilities are affected by this development. Howard B. Dutt, RLA Landscape Architect Tucson Parks & Recreation (520) 837-8040 Howard.Dutt@tucsonaz.gov >>> DSD_CDRC 7/27/2015 2:59 PM >>> Dear Reviewers: This is an electronic distribution for a CDRC Tentative Plat review. If you normally receive paper copies of the review documents, you will receive them soon. The applicable case numbers are: CDRC Development Plan: DP15-0114 Existing and Proposed Zoning: R-2 Proposed Use: Residential Subdivision Due Date: August 20, 2015 |
| 08/19/2015 | BVIESTE1 | COT NON-DSD | ENVIRONMENTAL SERVICES | Passed | |
| 08/20/2015 | ELIZABETH LEIBOLD | ENGINEERING | REVIEW | Reqs Change | DATE: August 20, 2015 TO: Bill Carroll, P.E., Engineering and Environmental Consultants, Inc. SUBJECT: Development Package Engineering 1st Review submittal PROJECT: Casa Seton Development Package Engineering Review LOCATION: 1777 N POTTER P, 123-01-017F, T14S R14E Sec5, Ward 6 IMPACT FEE AREA: Central FEMA PANEL: 2277L, Zone X-Unshaded WATERSHED: Flowing Wells Wash Watershed (a non-designated basin management area) REVIEWER: Elizabeth Leibold P.E. ACTIVITY NUMBER: DP15-0114 SUMMARY: The Development Package that includes the Tentative Plat, with conceptual grading a new subdivision Casa Seton, which was received and reviewed by Planning & Development Services Department Engineering Division. Development Services Department Engineering Division does not recommend approval of this Development Package at this time until the following comments are addressed. BASE PLAN SHEETS COMMENTS: 1) City of Tucson Administrative Manual Section (Admin Man Sec.) 2-06, and Unified Development Code (UDC Sec.) 8.3: In response letter, please explain whether this project will have a subsequent Grading Plan and SWPPP under a separate Development Package activity number. MASTER COVER SHEETS/ GENERAL NOTES: 2) Admin Man Sec.2-06.4: Assure all required general notes have been added to the cover sheet, including: a) Tech Man Sec.4-04.14.3.2(a)-(d) and 14.3.3: A mechanism must be provided by which some person, private party, or association is responsible for maintenance of the basin and other drainage facilities within the subdivision. The responsible entity must have sufficient financial resources to adequately maintain the drainageway in the future. For instance, a certain portion of the revenues of a homeowners' association must go for maintenance, and this must be clearly stated in the covenants, conditions, and restrictions of the association. Add these sections as general notes for maintenance for drainage and basin facilities. b) Admin Man Sec.2-06.4.7.A.6.a: List additional applications (such as TSMR), by case number in lower right corner of each sheet. As a general note provide the type of application processed, a statement that the project meets the criteria/conditions of the additional application, the case number, date of approval, what was approved, and the conditions of approval, if any. c) UDC Sec.8.6.2, Tech Man Sec.4-03.3.5.1.10: Add as note to sheet 1 that drainage improvements will need to be completed prior to release of lots 6, 7, and 8. d) Admin Man Sec.2-06.4.8.G: For Tentative Plat review, add note or label on planview that existing pool area shall be removed or other notation as applicable. Specific information or notes for the pool removal shall be detailed on grading construction plans at the grading permit submittal review stage. Otherwise, if pool area has already been removed, clarify in response letter. SITE PLAN SHEET COMMENTS: 3) Admin Man Secs.2-06.4.8.D, 2-06.4.9.H: For detail G3 cross section and in planview, clarify dimensions for the vehicular and pedestrian access design south of parcel. 4) Admin Man Sec. 2-06.4.9.H, Tech Man. Sec.10-01.5.3: Clarify SVT's in Elm by adding label "per AASHTO" where AASHTO 15-ft leg is proposed to be used. 5) Although SVT's are required at Elm, remove the other SVT's at southeast side of parcel, since this location does not require SVT's per Tech Man. Sec.10-01.5.2.B.1. 6) Admin Man Sec.2-06.4.4.B: Clarify project-location map on sheet 1 to identify Wilson Wash. 7) Admin Man Sec.2-06.4.8.D: Identify entities along western property boundary west of basin; clarify whether these are existing sewer manholes or other objects; add sewer manhole symbol to legend. DRAINAGE REPORT COMMENTS: 8) Tucson Code Sec.26-5.2.11, UDC Sec.7.14.1&4, Tech Man Sec.4-04.2.2, 2.3.1: Drainage comments are provided to address those features that impact feasibility of the project and should be addressed prior to grading permit review, at Tentative Plat stage. Address the following Drainage Report comments: a) Tech Man Sec.4-03.3.5.1.3.a: There is a conflict with proposed sewer and the proposed basin - the City will not accept a sewer line under the proposed basin. There are compaction requirements for the utility trench which is in conflict with the basin requirement. Reconfigure basin or location of proposed sewerline. (See also Utility comment below) b) Tech Man Sec.4-04.2.3.1.5.C: Explain in response letter and provide in report which equation was used for proposed splash pad sizing computation. c) Tech Man Sec.4-03.2.2: Add thorough discussion of basin requirements and impact from soil conditions at the site. Include whether the site is in an area where 2-yr or 5-yr threshold retention is required. Add statement regarding any request for retention requirements due to subsurface soil constraints. The City of Tucson can not approve a project that proposes a basin that does not meet drain down time of 12-hours (safety factor to be included). The area indicates a Hydrologic Soil type D that is typically associated with soils that do not infiltrate. d) Tech Man Sec.4-03.3.5.1.4: Show bleed pipe in detail or planview. e) Tech Man Sec.4-04.2.3.1.3.A.6: Provide any sizing calculations for proposed subdivision perimeter wall openings. Assuring pre- and post developed conditions are thoroughly described in report. 9) Tech Man Sec.4-04.2.3: Specifically address other specific drainage report comments: a) Tech Man Sec.4-04.2.3.1.1: Add DP15-0114 case number and submittal number with date of 2nd submittal to report cover. Also, check page numbering - some pages have overlapping text. b) Tech Man Sec.4-04.14.3.3: Please do not copy PDF pages from Drainage Manual for maintenance guidelines; create specific guidelines for drainage and basin maintenance facilities for this specific site. See standard sections a and b. GRADING, PAVING, DETAIL SHEET COMMENTS: 10) Admin Man Sec.2-06.4.9.M.1, Tech Man Secs.2-01.4.1.C, 8-01.5.2.G: Address the following grading comments: a) Tech Man Sec.4-03.2.2 & 4-03.3.5.1.3.a: Clarify on cross sections and planviews how positive gradients and scuppers/outlets are provided for each basin/waterharvesting area. Hydrologic type D-soils are indicated at site. Retention may not be suitable for this site due to subsurface conditions. Waterharvesting shall be carefully designed, with positive gradients to assure drain down time of no more than 12 hours. Revise conceptual grading planview sheet to show positive gradients and any additional scuppers or bleed pipes. Provide additional spot elevations in the proposed basin area and north of basin. b) Admin Man Sec.2-06.4.9.M.1: Limits of grading shall coincide with needed fill on project site to accommodate slope or fill and construction area ; clarify that perimeter elevations are maintaining existing flow patterns, necessary construction area and fill runout on grading planview. Add flow arrows to show proposed lot drainage scheme on a planview that has conceptual grading information. c) Tech Man Sec.4-04.2.3.1.6.A.4.a: Clarify and label on all sheets any locations of toe downs at basin spillway entrance/exit. d) Admin Man Sec.2-06.4.9.N: Provide and label volume, Q100, 100-yr basin flow depth, exit velocities (pre- and post-developed conditions) on Tentative plat planview. e) Admin Man Sec.2-06.4.9.M.1: Provide additional data or other cross sections for conceptual grading design; delineate, dimension, and label existing sewer and water line easements at south and north areas of project. (See utility comments) f) Admin Man Sec.2-06.4.9.W, Tech Man Sec.4-04.2.3.1.5.C: Clarify locations for proposed subdivision perimeter walls and proposed wall openings. SURVEY RELATED COMMENTS: 11) Admin Man Sec.2-06.4.8.A: Label all parcel boundary and access easement perimeter bearings/distances on planview. 12) Admin Man Sec.2-06.4.9.M.1: Label and depict a local Basis of Elevation, on a conceptual grading sheet planview. UTILITIES / EASEMENTS COMMENTS: 13) Admin Man Sec.2-06.4.8.B, 2-06.4.9.L: On conceptual grading planview sheets, show any easements on and immediately adjacent to or overlapping the parcel. All easements shall be drawn on the plan. The recordation information, location, width, and purpose of all easements on site will be stated. Blanket easements should be listed in the notes, together with recordation data and their proposed status. Should an easement not be in use and be proposed for vacation or have been abandoned, so indicate. However, should the easement be in conflict with any proposed building location, vacation of the easement shall occur prior to approval of plan unless written permission from easement holder(s) is provided. Assure complete information is provided for easements on or impacting the site. All proposed easements (utility, sewer, drainage, TCE, maintenance, access, etc.) are to be dimensioned and labeled as to their purposes and whether they will be public or private. The easements may have to be recorded and the recordation information added to the development package prior to approval. Provide title report with next submittal. Specifically also address the following utility/easement comments: a) Admin Man Sec.2-06.4.8.B: On Tentative Plat sheet 2 (C2), show the (existing?) sewer easement at northern portion of project, including easement width, recording data, and delineation of easement limits both on and off site (if straddling property line). b) Tech Man Sec.4-04.2.3.1.5: There is a conflict with proposed sewer and the proposed basin - the City will not accept a sewer line under the proposed basin. Reconfigure basin or location of proposed sewerline. (See grading also comments). c) Admin Man Sec.2-06.4.8.B & 2-06.4.9.W: In order to assure grading and utility feasibility of proposed project layout, label and dimension horizontal and vertical distances from existing/proposed utility pipe lines (including waterlines) to proposed pavement at south entrance area and at proposed location of relocated wall. Contact utility offices for minimum dimension standards. (See grading also comments). d) Admin Man Sec.2-06.4.8.B: Explain in resubmittal and show on Tentative plat plan view or as a blanket easement note, the following Title Report related items: Schedule BI, item 9; and Schedule BII, item 5; STORMWATER POLLUTION PREVENTION PLAN COMMENTS: 14) The site appears to exceed 1 acre, so a SWPP is required if this development package is intended to be revised to include grading/SWPP. Otherwise please acknowledge that, at later development package submittal, sealed SWPP reports will be submitted per Tucson Code Chapter 26-2, with a copy of the SWPP exhibit in report (and in Development Package). SOILS/GEOTECHNICAL REPORT COMMENTS: 15) Tech Man Sec.4-03.2.2, Tech Man Sec.4-03.III.3.5.1.3.a: Explain and show on plans how Geotechnical Evaluation Report recommendations are met on plan. Assure recommendations for slopes, basin setbacks from building and private street, are reflected on plans. Submit soils report in next submittal. For resubmittal, provide revised development package including revised grading plan, one copy of the soils report, with comprehensive response letter, revised drainage report, copy of title report, and other documents. If you have questions, call me at 837-4934. Elizabeth Leibold, P.E., CPM, CFM Civil Engineer Engineering Division Planning & Development Services Dept |
| 08/20/2015 | BVIESTE1 | ENV SVCS | REVIEW | Reqs Change | The Tentative Plat has been reviewed on behalf of the Environmental Services Dept. and the following will need to be addressed on the resubmittal: · Add a general note stating the Refuse and recycling service is to be individual curbside service. Plastic containers (APCs) shall be placed and removed from the curbside collection area on the day of service, and shall be stored from public view and adjacent developments. In order to facilitate collection by the service vehicle, Lots 3 and 5 shall place their containers at a minimum ten feet inside Lot 4 and Lot 9 shall place its containers adjacent to its west property line. · Identify the APC placements for Lots 3, 5 and 9 on the plans and call them out with keynote(s). If there are any questions, I can be reached at kperry@perryengineering.net |
| 08/20/2015 | BVIESTE1 | OTHER AGENCIES | PIMA ASSN OF GOVTS | Approved | See additional documents in PRO. No objections/adverse comments. See attached. -------------------------------------------------------------------------------- Disclaimer: This report and/or data was funded in part through grant[s] from the Federal Highway Administration and/or Federal Transit Administration, U.S. Department of Transportation. The contents of this report and/or data reflect the views and opinions of the author(s) who is responsible for the facts and accuracy of the data presented herein. The contents do not necessarily state or reflect the official views or policies of the U.S. Department of Transportation, the Arizona Department of Transportation, or any other State or Federal Agency. This report and/or data does not constitute a standard, specification or regulation. The information in this publication is provided on an “as is” basis, and there are no warranties, express or implied, including, but not limited to, any warranties of merchantability or fitness for a particular purpose. In no event shall PAG be liable for any damages resulting from the use of the information. PAG provides the information in good faith and has endeavored to create and maintain accurate data. The users of this report and/or data are advised to use the information with caution and to independently verify accuracy. ____________________________ Eric W. Kramer, Ph.D., AICP Senior Land-Use Modeler 1 E. Broadway Blvd, Ste. 401 Tucson, AZ 85701 (520) 495-1455 (tel) (520) 620-6981 (fax) www.pagregion.com ekramer@pagregion.com |
| 08/20/2015 | JOE LINVILLE | LANDSCAPE | REVIEW | Approv-Cond | Submit any revised plans for an additional review. |
| 08/21/2015 | SSHIELD1 | H/C SITE | REVIEW | Reqs Change | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Steve Shields Lead Planner PROJECT: Casa Seton Accessibility Review - On Site Only Development Package (1st Review) DP15-0114 TRANSMITTAL DATE: August 21, 2015 DUE DATE: August 21, 2015 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. 1. Provide a note to that effect, that all accessible route slopes are to comply with ICC A117.1, Section 403.3; 5% maximum running slopes and 2% maximum cross slopes. 2. Provide running slope directional arrows, running slope percentages, for all sidewalks along the proposed private street. ICC A117.1-2009 403.3 and IBC 107.2.1 3. Provide PC/COT standard detail 207 on the plan. 4. Provide truncated domes at all proposed accessible ramps. 5. Demonstrate on the plan how accessibility will be addressed at the individual lot driveways. 6. As no detail or specification has been provided for the proposed refuge area along Potter Place additional comments my be forth coming. |
| 08/21/2015 | BVIESTE1 | UTILITIES | EL PASO NATURAL GAS | Passed | |
| 08/21/2015 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Reqs Change | 1. An approved development plan is not to be used for construction of on-site utilities (e.g. water service to buildings, building sewers, site lighting, or electrical service the buildings). A separate permit is required for the installation of a private sewer collection system. Reference: Title 18, R18-9-E302, 4.02 General Permit, Arizona Administrative Code. 2. A section of the new private sewer is shown crossing the retention basin CA 'B'. Clarify how this branch of the site sewer can be properly installed and backfilled without impairing the function of the retention basin. Reference: Section 306, IPC 2012. 3. Clarify how the existing private sewer located along the west side of the retention basin is to be accessed for repair within the proposed 4-foot wide space between the retaining wall for the retention basin and the existing wooden fence along the property line. 4. Revise the site drawing to include the points of connection to the proposed private sewer for each lot and the minimum first floor elevation for each lot. Determine the need for a backwater valve per Section 715.1, IPC 2012, as amended by the City of Tucson. Reference: City of Tucson Administrative Manual, Section 2-06.4.8D and Section 107.2.1, IBC 2012. |
| 08/21/2015 | BVIESTE1 | UTILITIES | CENTURYLINK | Passed | |
| 08/21/2015 | ROBERT YOUNG | PIMA COUNTY | PIMA CTY - DEV REVIEW | Passed | |
| 08/21/2015 | BVIESTE1 | OTHER AGENCIES | TUCSON AIRPORT AUTHORITY | Passed | |
| 08/21/2015 | BVIESTE1 | OTHER AGENCIES | U. S. POST OFFICE | Passed | |
| 08/24/2015 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Reqs Change | This review has been completed and resubmittal is required. Please resubmit the following items: 1) Two rolled sets of the plans 2) A disk containing all items submitted. 3) All items requested by review staff 4) All items needed to approve these plans |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 08/28/2015 | KROBLES1 | OUT TO CUSTOMER | Completed |