Permit Review Detail
Review Status: Completed
Review Details: RESUB - SITE and/or GRADING
Permit Number - DP15-0113
Review Name: RESUB - SITE and/or GRADING
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/08/2015 | MARTIN BROWN | FIRE | REVIEW | Approved | |
| 10/09/2015 | PAUL BAUGHMAN | ENGINEERING | REVIEW | Approved | October 12, 2015 FLOODPLAIN USE PERMIT NO.: T15OT00961 ADDRESS: 5450 S. Country Club, Tucson Arizona 85706 PROPERTY OWNER: Brown Garold C Family LP 5901 S Belvedere Ave, Tucson, AZ 85706 The use a portion of the FEMA Special Flood Hazard Area Zone AH per the Flood Insurance Rate Maps 04019C2293L, specifically described as: A portion of Parcel 140-10-002C, PTN W330.02' E390.02' N603.72' SE4 LYG S & ADJ RD 4.58 AC SEC 5-15-14 For the purpose of constructing a 400LF wrought iron fence, pavement and landscaping. The applicant agrees to comply with City of Tucson Floodplain and Erosion Hazard, and Watercourse Amenities, Safety and Habitat regulations, and is particularly bound by the conditions stated below. Violation of any of the conditions stated or referred to below, as determined by the City Engineer, shall be grounds for revocation of this permit. Responsibility for renewal of this permit, if necessary, is with the applicant. Issuance of this permit does not constitute a waiver of other requirements contained in the Tucson City Code, Unified Development Code, or any other Federal, State, County, or local regulation. No use other than as permitted herein is allowed. Additional uses allowed under City of Tucson Floodplain and Erosion Hazard Regulations and Watercourse Amenities, Safety, and Habitat regulations require the issuance of an additional Floodplain Use Permit. The following 8 conditions apply to this permit: 1) This permit becomes invalid and is subject to additional floodplain review, if any required development changes the construction of the 400LF wrought iron fence, pavement and landscaping, or, if there is any further disturbance within the floodplain other than that outlined in this application. This floodplain use permit may be subject to conditions or restrictions designed to reduce or mitigate the potential damage or hazard to life or property resulting from the construction of 400LF wrought iron fence, pavement and landscaping within the regulatory floodplain, floodway or erosion hazard areas as determined by the project engineer and accepted by the City of Tucson. 2) Except as approved by the City Engineer prior to the start of construction, development under this permit shall not obstruct, retard or divert the existing flow of floodwaters from or to adjacent properties. 3) All work shall conform to the approved site plan sheets for the construction of the 400LF wrought iron fence, pavement and landscaping, which are made part of this permit. 4) Within 5 (five) days of issuance of this permit, and through completion of the project, notification must be posted and maintained in a conspicuous place on the job site stating "CONSTRUCTION PROCEEDING UNDER REQUIREMENTS OF CITY OF TUCSON FLOODPLAIN USE PERMIT # T15OT00961 FOR INFORMATION PLEASE CALL 791-5550." 5) This Floodplain Use Permit and plans shall be kept in a readily accessible location on site at all times. 6) Any additional future disturbance of the floodplain shall have separate floodplain use permit applications submitted to this office for review and approval. 7) See the associated activity DP15-0113 8) This permit is specific to the improvements for 5450 S Country Club as indicated on the approved plans. It shall not apply to any other structure or property, whether attached or unattached, not specified under this permit. Renewal of this permit will require a new application, review and approval of that application by the City of Tucson, Planning & Development Services Department, Engineering Division. This permit may be renewed for up to one year, in the absence of Registered Plant authorization, at the sole discretion of the City Engineer or designated representatives. This Floodplain Use Permit will be automatically revoked and becomes invalid if conditions are not complied with, as set forth in this permit. APPLICANT NAME: Jeffrey A Stanley, PE ADDRESS: P O Box 1888, Tucson, AZ 85702 PHONE: 520-390-7920 CONTRACTOR: TBD ADDRESS: TBD PHONE: TBD (EXPIRATION DATE) Month: _10 Day: 12_ Year: 2016 SIGNATURE OF APPLICANT DATE The applicant is authorized by the City Engineer to receive a floodplain use permit subject to the above referenced conditions and restrictions. |
| 10/27/2015 | ANDREW CONNOR | LANDSCAPE | REVIEW | Reqs Change | UNIFIED DEVELOPMENT CODE ARTICLE 7: DEVELOPMENT STANDARDS The following comment was not addressed from previous review: All required screening must be provided on the developing property or a joint use agreement must be provided indicating that the adjacent wall may be used to meet the screening requirement. Joint use agreement must be provided before the plan can be approved and the recording information for the joint use agreement must be referenced on the plan. Verify that the adjoining wall complies with the height requirement as measured from the adjacent grade being developed. The requirement is measured from the use requiring the screening. The wall can not be used as a retaining wall that lowers the minimum height. A cross section should always be provided on the plan showing the adjacent grades and the measurement of the wall height. The existing block wall appears to be installed for the adjacent subdivision. Provide Joint Use Agreement or appropriate screening on the development side of site. Additional comments may apply |
| 10/27/2015 | MICHAEL ST. PAUL | HC SITE | REVIEW | Approved | |
| 10/27/2015 | MICHAEL ST. PAUL | ZONING | REVIEW | Approved | |
| 10/27/2015 | ANDREW CONNOR | NPPO | REVIEW | Approved |