Permit Review Detail
Review Status: Completed
Review Details: DEV PKG - RESUBMITTAL
Permit Number - DP15-0108
Review Name: DEV PKG - RESUBMITTAL
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
10/21/2015 | CPIERCE1 | START | PLANS SUBMITTED | Completed | |
10/22/2015 | MARTIN BROWN | COT NON-DSD | FIRE | Approved | |
11/03/2015 | DAVID RIVERA | ZONING HC | REVIEW | Reqs Change | See zoning comments. |
11/03/2015 | DAVID RIVERA | ZONING | REVIEW | Reqs Change | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: David Rivera Principal Planner PROJECT: DP15-0108 Address: 550 S Stone Avenue Development Package: Civic Use - Jewish History Museum TRANSMITTAL DATE: November 3, 2015 DUE DATE: November 19, 2015 COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. Follow up comment to previous comment 27: THe slopes on the proposed ramps were not labled. Label the slopes and resubmit the drawings for zoning review. Zoning is willing to review and approve the plans over the counter once the changes have been made. 2-06.4.9.R - Show on-site pedestrian circulation and refuge utilizing location and the design criteria in Section 7-01.0.0, Pedestrian Access, of the Technical Standards Manual. 27. COMMENT: During a site visit it was noted that there is construction ongoing on the site. The plan depicts an existing ramp system. However it does not appear that ramp system as depicted on the plan is consistent or currently accurate with what may be being built on site. Revise as necessary. Provide the cross and running slopes of the pedestrian accessible route. Indicate if access point to the building area flush with the landings. Indicate on the plan where the accessible/pedestrian route is provided to the new structure. Dimension the width of the sidewalk/ramp system and the width and length of the turnaround landings. If necessary include a blowup detail drawing of the ramp system with dimensions, direction of travel and slopes, call out for rails and an elevation detail drawing of the ramp and hand rails. Refer to Chapter 4 in ICC A117.1-2009 for requirements. ********************************************************************* If you have any questions about this transmittal, please call David Rivera, (520) 791-5608. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package site plan and any requested documents. |
11/13/2015 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Completed | |
11/17/2015 | ANDREW CONNOR | LANDSCAPE | REVIEW | Approved | |
11/18/2015 | LOREN MAKUS | ENGINEERING | REVIEW | Approved | |
11/20/2015 | BVIESTE1 | ZONING-DECISION LETTER | REVIEW | Reqs Change | This review has been completed and resubmittal is required. Please resubmit the following items: 1) 4 Rolled sets of the plan 2) All items requested by review staff 3) And all items needed to approve the plan |
11/20/2015 | FDILLON1 | DESIGN PROFESSIONAL | REVIEW | Approved |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
12/04/2015 | EGALLET1 | OUT TO CUSTOMER | Completed |