Permit Number: DP15-0102
Parcel: 305972280

Review Status: Completed

Review Details: RESUB - SITE/GRADING ALL

Permit Number - DP15-0102
Review Name: RESUB - SITE/GRADING ALL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
12/14/2015 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Reqs Change The second submittal shows that lots 197,224, 245, 246, 258, and 289 still require backwater valves. Lots 184, 237, 290, 291, 321, 340, and 342 have backwater valves but do not need them. Lot 248 shows a backwater valve on sheet PS11 but not on sheet G7; it requires a backwater valve. Backwater valves shall be installed only where necessary. Reference: Section 715.1, IPC 2012. [Initial comment: Verify the need for a backwater valve at the following lots: 172, 184, 197, 224, 231, 237, 245, 246, 247, 248, 258, 259, 261, 289, 290, 291, 321, 340, and 342. If the FFE is 12" or more above the rim elevation of the next upstream manhole, no backwater valve shall be installed. Reference: Section 715.1, IPC 2012.]
12/15/2015 DAVID RIVERA ZONING REVIEW Approved
12/16/2015 MARTIN BROWN FIRE REVIEW Approved
12/17/2015 LOREN MAKUS ENGINEERING REVIEW Approved
12/21/2015 ANDREW CONNOR NPPO REVIEW Approved
12/21/2015 ANDREW CONNOR LANDSCAPE REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
12/22/2015 PGEHLEN1 APPROVAL SHELF Completed
12/22/2015 PGEHLEN1 OUT TO CUSTOMER Completed
12/22/2015 PGEHLEN1 REJECT SHELF Completed