Permit Number: DP15-0064
Parcel: 133291870

Review Status: Completed

Review Details: RESUB - SITE and/or GRADING

Permit Number - DP15-0064
Review Name: RESUB - SITE and/or GRADING
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/10/2015 DAVID RIVERA ZONING REVIEW Reqs Change FROM: David Rivera
Principal Planner

PROJECT: DP15-0064
Address: 8421 e Broadway Boulevard
Development Package: Ice House America Kiosk

TRANSMITTAL DATE: June 10, 2015

DUE DATE: July 7, 2015

COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is April 16, 2016.


01. Follow up to previous comment 3: The TSMR was not approved by all plans reviewers and therefore the DP cannot be approved. Once the TSMR is approved whether outright or conditional, the TSMR case number, date of approval and conditions of approval must be listed as a general note on the cover sheet.

PREVIOUS COMMENT 03: A TSMR review and approval will be required for the proposed sidewalk area utilizing the pavement as the surface material. List the TSMR case number in the lower right corner of all plan sheets and list as a general note the TSMR case number, date and conditions of approval.
*********************************************************************


02. Follow up to Previous Comment 5: There was no response to previous comment 5. Clarify if a request to the zoning administrator was made relevant to previous comment 5. Include in the next submittal some form of communication from the Zoning administrator providing direction with regards to this issue.

PREVIOUS COMMENT 05: UDC section 4.9.13.O.2 requires that all activity occur within an enclosed building. The Ice Kiosk is a Vending Machine and technically would have to be within a building. I believe that you should contact the zoning administration staff to get a determination and it is possible that a determination has already been made in the past which may be used for this project. Contact Russlyn Wells at 837-4948 for more information.
*********************************************************************


03. Follow up to previous comment 16: The TSMR has not been approved. Refer to the CDRC managers instructions provided in the CDRC memo.

PREVIOUS COMMENT 16: As noted in comment 3, a TSMR approval for the proposed paved striped pedestrian area that must include some type of physical barrier will be required.
*********************************************************************


04. Comment: Revise the DP to address the HC denial comment.

If you have any questions about this transmittal, please call David Rivera, (520) 791-5608.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package site plan and any requested documents.
06/10/2015 DAVID RIVERA HC SITE REVIEW Reqs Change Previous comment was not addressed on the revised DP site plan.

01. Previous HC Comment: Insure by a note on the drawing that the accessible route is extended to the Broadway right of way.
06/24/2015 JASON GREEN ENGINEERING REVIEW Reqs Change DATE: June 24, 2015
DUE DATE: July 07, 2015
SUBJECT: New Ice Kiosk Development Plan Package- 2nd Engineering Review
TO: MetroTED; Attn: Lisa Bowers
LOCATION: 8421 E Broadway Blvd
REVIEWERS: Jason Green, CFM
ACTIVITY: DP15-0064

SUMMARY: Engineering Division of Planning & Development Services Department has received and reviewed the proposed Development Package. Engineering Division does not recommend approval of the Development Package at this time. This review falls under the Unified Development Code (UDC), Administration Manual (AM) and Technical Standards Manual (TSM). Refer to the following link for further clarification:
http://www.amlegal.com/nxt/gateway.dll/Arizona/tucson_az_udc/administrativemanual?f=templates$fn=default.htm$3.0$vid=amlegal:tucson_udc_az

The following items need to be addressed:

SITE PLAN:

1) Complied.
2) Complied.

3) Acknowledged: AM Sec.2-06.4.3: Revise the development package and the TSMR case number on all sheets to read DS15-11 not D515-11.

4) Complied.
5) Complied.
6) Complied.
7) Complied.

8) Acknowledged: AM Sec.2-06.4.8.C: The 3 driveways have been labeled and dimensioned on the development package; however it appears that the ice kiosk may encroach into the most western driveway. Provide verification of the PAAL width onsite for existing and future right-of-way for the ice kiosk adjacent to the vehicular use area. Confirmation through TDOT maybe required to ensure that the ice kiosk does not adversely impact the driveway location for safety reason. If the driveway is to be closed off label the curbing and sidewalk dimensions along with a reference to the Standard Detail for Public Improvements to match existing for construction purposes. Existing curb cuts that are no longer used must be closed off per Tucson Code Chapter 25 Sec.25-43.

9) Complied.

10) Restated: AM Sec.2-06.4.9.H.5.a: Revise the development package to correctly dimension the three foot radii for the backup spur.

11) Complied.
12) Complied.
13) Complied.

14) Restated: AM Sec.2-06.4.9.R: Revise the development package to provide a General Note referencing the TSMR Case #, date of approval and any conditions (if applicable). The TSMR (DS15-11) has not been approved at this time for the modification of the sidewalk. Once the TSMR is approved then the note needs to be added with the approval date.

15) Complied.

GENERAL COMMENTS:

Please provide a revised Development Package that addresses the comments provided above. Include a comprehensive response letter addressing in detail responses to all of the above comments.

For any questions or to schedule meetings call me at 837-4929.



Jason Green, CFM
Senior Engineer Associate
Engineering Division
Planning & Development Services Department
07/01/2015 ANDREW CONNOR LANDSCAPE REVIEW Reqs Change Ensure that all Zoning & Engineering comments and concerns are addressed prior to Landscape approval.