Permit Review Detail
Review Status: Completed
Review Details: SITE and/or GRADING
Permit Number - DP14-0229
Review Name: SITE and/or GRADING
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/11/2014 | MARTIN BROWN | FIRE | REVIEW | Approved | |
| 12/11/2014 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Approved | |
| 12/11/2014 | ANDREW CONNOR | NPPO | REVIEW | Approved | |
| 12/11/2014 | RONALD BROWN | H/C SITE | REVIEW | Passed | |
| 12/11/2014 | ANDREW CONNOR | LANDSCAPE | REVIEW | Approved | |
| 12/11/2014 | RBROWN1 | ADA | REVIEW | Approved | SHEET 3 of 16 1. Provide a note stating that all new accessible routes are to comply with the 2010 ADASAD, Section 403.3; 1:20 maximum running slopes and 1:48 cross slopes. a. Provide several down arrows on the accessible route with slope percentages shown as was shown on the parking lot partial site plan on sheet 4 of 16. SHEET 4 of 16 2. At detail 2/C2 a. Detectable warnings are only required at transportation platforms. Please remove the requirement for truncated domes at the entry to the accessible parking aisle. b. Provide a note that the grade slopes for the accessible parking and aisle areas are to be maximum of 1:48. c. Provide a dimension for the width of the accessible route. d. Provide down slope arrows and slope percentages on the ramps. SHEET 6 of 16 3. Provide a couple more down slope arrows and slope percentages on the accessible route. END OF REVIEW |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 12/15/2014 | AROMERO4 | OUT TO CUSTOMER | Completed |