Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Completed
Review Details: RESUB - SITE and/or GRADING
Permit Number - DP14-0202
Review Name: RESUB - SITE and/or GRADING
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
12/12/2014 | DAVID RIVERA | ZONING | REVIEW | Approv-Cond | FROM: David Rivera Principal Planner PROJECT: DP14-0202 4004 S. Park Avenue Development Package - COT Compressed Natural Gas Plant Replacement TRANSMITTAL DATE: December 12, 2014 DUE DATE: December 16, 2014 COMMENTS: Zoning is conditionally approving the DP subject to providing the recordation information for the new drainageway easement and revising sheet C1.0 2-06.4.9.L - All proposed easements (utility, sewer, drainage, access, etc.) are to be dimensioned and labeled as to their purposes and whether they will be public or private. The easements may have to be recorded and the recordation information added to the development package prior to approval. 01. COMMENT: If applicable draw, dimension and label the information as noted by the standard above. ****************************************************************************************** If you have any questions about this transmittal, please call David Rivera, (520) 791-5608. |
12/23/2014 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Completed | |
12/23/2014 | ELIZABETH LEIBOLD | ENGINEERING | REVIEW | Approved | TO: Rudy Ing, P.E. DATE: December 23, 2014 SUBJECT: Engineering Review Development Package (SP/GP/SWPP) 2nd submittal Engineering Review ADDRESS: 4004 S Park Av T14S R13E Sec36 PROJECT: COT CNG Plant & Associated Drainage Improvements and Pavement Maintenance FLOODPLAIN: Local jurisdictional floodplain, FEMA zone X-unshaded, 2287L WATERSHED: Julian Wash Watershed (BW) Balanced Basin Management area REVIEWER: Elizabeth Leibold, P.E. PROJECT: DP14-0202, T14CM07391 SUMMARY: Engineering has reviewed the revised Development Package for site plan and grading review including Drainage Report review. ERR Report is acceptable for this project. Per Tech Man.4-04.2.3.1.5.G, Engineering recommends approval of the Development Package with following conditions to be addressed during or before grading construction. PERMIT CONDITIONS: The following 11 conditions apply to permits DP14-0202 & T14CM07391: 1) Recordation of offsite Public Drainage & Maintenance Easement shall be obtained prior to commencement of construction. 2) Call for Pre-construction meeting. For a City of Tucson Planning & Development Services Department (PDSD) Engineering Inspection, call IVR (740-6970), or schedule with a Customer Service Representative at the Planning & Development Services Department - Angie 837-4917, or contact PDSD Engineering at 837-4888, or schedule inspections online at: http://www.ci.tucson.az.us/dsd/Online_Services/Online_Permits/online_permits.html 3) PDSD Inspector shall be called to inspect special grading/drainage improvements, such as drainage system's hydrodynamic separator installations, and outlet when under construction. 4) Copy of approved plan/permit DP14-0202 shall be kept at site at all times until final grading approval. These sets of plans act as the approved grading plan for the City of Tucson Compressed Natural Gas Plant Replacement Development Plan sealed by Rudolf Andrew Ing P.E. on 12.05.14. 5) There shall be no disturbance outside of disturbance/grading limits as shown on approved grading and SWPPP plans. 6) Contact Permits & Codes (837-6606) for questions regarding City of Tucson right-of-way permit requirements. 7) If grading construction is expected to last longer than the expiration date of the grading permit, contact PDSD to renew/extend the Grading Permit. If Final Grading Inspection has not been completed before the Grading Permit expires, and the permit has not been renewed, additional fees and reviews may be required. 8) Revisions to the design must be discussed with a Civil Engineer at PDSD Engineering Division, prior to any construction activity, to determine whether additional details, calculations, drainage report, or a revised grading plan is needed, or, whether changes may be provided on as-builts. 9) Permittee shall notify PDSD Inspector when grading operation is ready for final grading inspection. Final grading approval shall not be given until all work, including installation of all drainage improvements and their permanent protective devices, and all permanent erosion control measures have been completed in accordance with approved grading plan and grading permit, and all conditions of permit are completed. Any other exposed areas that are not reseeded shall be covered in gravel, unless other material is proposed, reviewed, and accepted by City of Tucson. 10) Temporary erosion and sediment control devices shall be placed at locations where stormwater runoff exits grading limits to prevent debris, construction silt, and/or chemicals from entering streets or any drainage ways. Any interim erosion and sediment controls that are installed should be maintained, per approved SWPPP plans or Operator with consultation with EOR and Inspector as needed, at downstream areas of disturbance limits. These interim controls must be removed after all permanent controls have been established. 11) Project Engineering completion letters, as well as Final Revised Grading Plan (as-builts) are required to be submitted prior to final Grading Inspection. Letter of certification from Engineer of Record for project substantial completion is required and submitted prior to final grading inspection. As-builts should include as-built elevations for finished drainage system inlets, outlet area, and other areas as deemed needed by surveyor, as well as sequence number for recorded offsite easement. If you have questions, call me at 837-4934. Elizabeth Leibold, P.E., CPM, CFM Civil Engineer Engineering Division Planning & Development Services Department |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
03/19/2015 | CPIERCE1 | APPROVAL SHELF | Completed |
03/19/2015 | SHANAE POWELL | OUT TO CUSTOMER | Completed |