Permit Number: DP14-0197
Parcel: 12101005A

Address:
6105 E PIMA ST

Review Status: Completed

Review Details: GRADING

Permit Number - DP14-0197
Review Name: GRADING
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
12/03/2014 JASON GREEN ENGINEERING REVIEW Reqs Change DATE: December 09, 2014
DUE DATE: December 16, 2014
SUBJECT: Alamo Crossing Grading Plan Development Plan Package- Engineering Review
TO: Rick Engineering Co., Attn: Dan Castro
LOCATION: 6105 E Pima St; T14S R14E Sec01
REVIEWERS: Jason Green, CFM
ACTIVITY: DP14-0197


SUMMARY: Engineering Division of Planning & Development Services Department has received and reviewed the proposed Development Plan Package, Drainage Report (Rick Engineering Co, 30MAY14 revised 25AUG14 and 15OCT14), Geotechnical Evaluation (Western Technologies Inc., 17NOV14) and Stormwater Pollution Prevention Plan (Rick Engineering Co, 17NOV14). Engineering Division does not recommend approval of the Development Plan Package at this time. This review falls under the Unified Development Code (UDC), Administration Manual (AM) and Technical Standards Manual (TSM). Refer to the following link for further clarification:
http://www.amlegal.com/nxt/gateway.dll/Arizona/tucson_az_udc/administrativemanual?f=templates$fn=default.htm$3.0$vid=amlegal:tucson_udc_az

The following items need to be addressed:


SITE PLAN:

1) AM Sec.2-06.4.3: The relevant Development Plan Package case number (DP14-0197) may be added to the lower right hand corner of the plan on all sheets.

2) AM Sec.2-06.4.9.M: Revise the grading plan to match the last approved development plan package (Tentative Plat) in design, locations, dimensions and construction details for the project. If the grading plan changes in details, locations, or construction methods then the tentative plat will need to be revised to reflect those changes. Each plan set should match and all details should be clearly shown on the grading plan which is to be used as the construction document.

3) AM Sec.2-06.4.9.N.1: Revise the grading plan to provide specific details for the proposed retention basins with dimensions and depths to ensure the volumes shown on the approved development plan package (Tentative Plat). The dimensions shown differ from the Tentative Plat.

4) AM Sec.2-06.4.9.N.2: Revise the grading plan to provide construction details for all outlets, inlets, curb opening, spillway details, etc. to match the approved development plan package (Tentative Plat). All construction details, keynotes, etc, shown on the Tentative Plat must also be shown on the grading plan which is to be used as the construction document.

5) AM Sec.2-06.4.9.N.2: Revise the grading plan to show rock rip rap in all location with method of placement as per the approved development plan package (Tentative Plat). If the method of placement has changed provided written verification from the engineer of Record.

6) AM Sec.2-06.4.9.R: Revise the grading plan and all applicable details and Keynotes to reflect the sidewalk construction within the private street as shown on the last approved development plan package (Tentative Plat).

7) AM Sec.2-06.4.9.S: Revise the grading plan and all applicable details and Keynotes to reflect the sidewalk construction within the right-of-way as shown on the last approved development plan package (Tentative Plat).


SWPPP:

8) Per City of Tucson Code Ordinance 10209, Chapter 26 Section 26-42.2: "For land disturbing activities that fall under the jurisdiction of this Article, a Stormwater Pollution Prevention Plan must be prepared and certified by an engineer, or a landscape architect and submitted along with the application for a grading permit to the City of Tucson Development Services Department." The SWPPP report must be signed and sealed by the engineer of record or by a Registered Landscape Architect, revise.


GENERAL COMMENTS:

Please provide a revised grading plan package that addresses the comments provided above. Due to the changes on the grading plan compared to the last approved Tentative Plat and the missing construction details further comments maybe forth coming upon the second review. Include a comprehensive response letter addressing in detail responses to all of the above comments.

For any questions or to schedule meetings call me at 837-4929.


Jason Green, CFM
Senior Engineer Associate
Engineering Division
Planning & Development Services Department
12/09/2014 STEVE SHIELDS ZONING REVIEW Reqs Change CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Steve Shields
Lead Planner

PROJECT: Alamo Crossing
Development Package, Grading Only (1st Review)
DP14-0197

TRANSMITTAL DATE: December 9, 2014

DUE DATE: December 16, 2014

1. The grading plan has been reviewed by Zoning Review Section but cannot approve the plan until all zoning comments or concerns have been addressed.

2. The grading plan does not match the tentative plat. See Engineering comments.

3. Zoning cannot approve the grading plan until Engineering and Landscape review sections have approved the plan.

4. Zoning will re-review the grading plan on the next submittal to insure compliance with the approved tentative plat. Additional comments may be forthcoming.

If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956
12/11/2014 ANDREW CONNOR NPPO REVIEW Reqs Change Ensure that all Engineering comments and concerns are addressed prior to Landscape/ NPPO approval signature.

Final Status

Task End Date Reviewer's Name Type of Review Description
01/16/2015 KROBLES1 APPROVAL SHELF Completed
01/16/2015 KROBLES1 OUT TO CUSTOMER Completed
01/16/2015 CPIERCE1 REJECT SHELF Completed