Permit Review Detail
Review Status: Completed
Review Details: DEV PKG - RESUBMITTAL
Permit Number - DP14-0182
Review Name: DEV PKG - RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/18/2016 | EGALLET1 | START | PLANS SUBMITTED | Completed | |
| 03/22/2016 | ANDREW CONNOR | LANDSCAPE | REVIEW | Approved | |
| 03/24/2016 | SSHIELD1 | HC SITE | REVIEW | Approved | |
| 03/24/2016 | LOREN MAKUS | ENGINEERING | REVIEW | Approved | |
| 03/24/2016 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Steve Shields Lead Planner PROJECT: HomeGoods Distribution Center Development Package (Revision) DP14-0182 TRANSMITTAL DATE: March 24, 2016 DUE DATE: March 25, 2016 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM). 1. 2-06.3.1 - The sheet provided is a combination of two (2) sheets, A0.1 & A1.0. Sheet A0.1 "PROJECT DATA" will need to revised and submitted for review. Sheet A1.0 remove the "PROJECT DATA" from this sheet and provide on sheet A0.1. 2. 2-06.3.5 - Provide the PDSD approval stamp, legal description and applicable case numbers as shown on the approved development package sheets A0.1 & A1.0. 3. 2-06.4.7.A.8.a - As you are proposing an "ENCLOSED SMOKE SHELTER" revise the "PROJECT DATA" "BUILIDING AREA" & "PARKING DATA" to reflect the square footage of the smoke shelter. If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package |
| 03/25/2016 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Reqs Change | This review has been completed and resubmittal is required. Please resubmit the following items: 1) Two rolled sets of the plans 2) All items requested by review staff 3) All items needed to approve this plan |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 07/02/2018 | AHINES2 | OUT TO CUSTOMER | Completed |