Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: DP14-0167
Parcel: 141220250

Address:
9095 S RITA RD

Review Status: Completed

Review Details: DEV PKG - REVISION

Permit Number - DP14-0167
Review Name: DEV PKG - REVISION
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
05/02/2018 BLARSON1 START PLANS SUBMITTED Completed
05/08/2018 MARTIN BROWN FIRE REVIEW Approved
05/14/2018 EHAMBLI1 ZONING REVIEW Reqs Change CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Elisa Hamblin, AICP
Lead Planner

PROJECT: Interstate Commerce Park
Development Package (1st Review)
DP14-0167

TRANSMITTAL DATE: May 14, 2018

DUE DATE: May 21, 2018

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is April 24, 2019.


CONTENT REQUIREMENTS

2-06.4.7 - General Notes
The following general notes are required. Additional notes specific to each plan are required where applicable.

2-06.4.7.A - Zoning and Land Use Notes

2-06.4.7.A.8 - For development package documents provide:

1. 2-06.4.7.A.8.a and b - On sheet C1, revise floor areas for buildings and totals provided. Errors are noted on total for lot 10A, the coverage for 10B, and the total and coverage for all combined lots.

2. 2-06.4.7.A.8.a - Provide updated information on floor area for building H on sheet C4. Update all information for building H on sheet C4. Sheets C3 and C4 do not match.

2-06.4.9 - Information on Proposed Development
The following information on the proposed project shall be shown on the drawing or added as notes.

3. 2-06.4.9.B - Provide square footage of each existing or proposed lot.
4. 2-06.4.9.H.5. - Per UDC Article 7.4.6.F.2.a, all access lanes and PAALs must be setback at least one foot from structure when the access lane or PAAL serves as a drive-through lane. Demonstrate compliance with this Article on buildings D, E and H.

5. 2-06.4.9.H.5.a - Parking calculations on sheet C1 appear to be incorrect. The total square feet for retail and restaurant uses do not total the square feet provided in general note 16. Update general note 17 as necessary.

6. 2-06.4.9.H.5.a - Correct parking calculations for spaces required for the physically disabled. Also clarify locations of these spaces on the drawing. Accessible spaces are noted as 9 required and 18 provided. Nine spaces are required, however 18 are not visible on the drawing. Van accessible spaces are noted as 2 required and 14 provided. Three spaces are required but only 1 is visible on the drawing.

7. 2-06.4.9.H.5.a - The reduced parking dimension of 15 ft. on the south side of building E is not permitted. A 15.5 ft. dimension is allowable only if the parking overhang into the pedestrian area (2.5 ft.) leaves sufficient area for pedestrians. All sidewalks must be a minimum of four feet wide. Provide dimensions for the pedestrian area on building E.

8. 2-06.4.9.H.5.d - Bicycle parking calculations on sheet C1 appear to be incorrect. Retail Trade Uses Less Than 50,000 sq. ft. GFA require a total of 1 long-term bike parking space per 12,000 square feet, with a minimum of 2 required (UDC Table 7.4.8-1). Only 1 long-term bike parking space has been noted. Update parking calculations and general note 17 as necessary.

9. 2-06.4.9.R - Provide pedestrian circulation path throughout the development, as outlined TSM Section 7-01.3.0. Pedestrian circulation is not provided between buildings F and E.

10. 2-06.4.9.T - Demonstrate how the provided refuse collection locations are accessible to pedestrians. A misplaced trash enclosure appears to be located in the access lane to the east of building F.

11. 2-06.4.9.T - Identify the proposed refuse collections locations for buildings H and G.

If you have any questions about this transmittal, please contact Elisa Hamblin at (520) 837-4966 or Elisa.Hamblin@tucsonaz.gov or Steve Shields at (520) 837-4956 or Steve.Shields@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
05/14/2018 EHAMBLI1 ZONING HC REVIEW Reqs Change See zoning comments
05/16/2018 ANDREW CONNOR LANDSCAPE REVIEW Reqs Change UNIFIED DEVELOPMENT CODE
4.1 Identification and Descriptive Data
A. All improvements and site information, such as buildings and site infomation, shown on the landscape plan will be identical in size and location to those shown on the base plan (site plan or tentative plat). Should amendments be required to the base plan through the review process, the same amendments will be made to the landscape plan which will then be resubmitted along with the base plan.
Ensure that all Zoning and Engineering comments and concerns are addressed prior to landscape approval.
05/22/2018 JOHN VAN WINKLE ENGINEERING REVIEW Reqs Change DP14-0157

1) Pima Associations of Governments "PAG" standard details have been adopted to replace City of Tucson Standard Details. Update notes on all sheets to reference the appropriate "PAG" standards. See following link http://apps.pagnet.org/standardspecifications/
2) Add note reference to DP17-0305
3) Sheet C4. Provide location of Key Note 14. Update Keynote 14 to reference City of Tucson Standards Technical Standards Manual (TSM) section 8-01.9.0 Figure 3B.
4) Sheet 3 Keynote 14. Dimensions for trash enclosure to the south show 13'x10' and include a hatched area showing the extended concrete pad. The other trash enclosures are dimensioned 11'x12' and do not have a hatched area in front. Update all details ensuring they follow the detail referenced in comment 3.
5) Landscape Architect Seal is expired, provide updated seal on applicable sheets

John Van Winkle, P.E.
John.VanWinkle@tucsonaz.gov
520-837-5007
05/22/2018 ALEXANDRA HINES ZONING-DECISION LETTER REVIEW Reqs Change This review has been completed and resubmittal is required. Please resubmit the following items:
1) Two rolled sets of the plans
2) All approved documents submitted previously
3) A disk containing all items submitted
4) All items requested by review staff
5) All items needed to approve these plans
05/22/2018 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Completed

Final Status

Task End Date Reviewer's Name Type of Review Description
05/23/2018 KROBLES1 OUT TO CUSTOMER Completed