Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: DP14-0167
Parcel: 141220250

Address:
9095 S RITA RD

Review Status: Completed

Review Details: DEV PKG - REVISION

Permit Number - DP14-0167
Review Name: DEV PKG - REVISION
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
11/25/2016 LBOJORQ1 START PLANS SUBMITTED Completed
11/30/2016 STEVE SHIELDS ZONING REVIEW Reqs Change CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Steve Shields
Lead Planner

PROJECT: Interstate Commerce Park Lots 8 -11
Development Package (Revision #3)
DP14-0167

TRANSMITTAL DATE: December 1, 2016

DUE DATE: December 07, 2016

COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

SECTION 2-06.0.0: DEVELOPMENT PACKAGE (TENTATIVE PLATS AND SITE PLANS)
Section

1. 2-06.4.9.H.5 Sheet C2 south end near the billboard there is a keynote 45 the calls out for "STABILIZED AGGREGATE BASE FOR LOADING ZONE ACCESS". This surfacing does not meet the requirements of UDC Article 7.4.6.I.

2. 2-06.4.9.X - The Design Development Option (DDO) will need to be approved prior to approval of the development package revision.

3. Sheet C2 there is a keynote 29 shown at the south end of the access to the billboard. Keynote 29 has been deleted from the keynotes.

4. Sheet C2 there is a keynote 46 shown just north of the billboard, see orange high light, that points to know where.

5. Sheet C2 there is a keynote 44 shown south of entrance off of Rita Road, see orange high light, that points to know where.

6. The last approved plan shows a revision 2. Clarify why revision 2 has been removed from this set of plans.


If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
.
12/06/2016 ANDREW CONNOR LANDSCAPE REVIEW Reqs Change UNIFIED DEVELOPMENT CODE
4.1 Identification and Descriptive Data
A. All improvements and site information, such as adjacent rights-of-way and property lines, shown on the landscape plan will be identical in size and location to those shown on the base plan (site plan or tentative plat). Should amendments be required to the base plan through the review process, the same amendments will be made to the landscape plan which will then be resubmitted along with the base plan.
7.6.4. LANDSCAPE STANDARDS:
Use of the Public Right-of-Way
Non-required landscaping may be placed in the public right-of-way, if the following standards are met:
1. The landscaping is approved by the City Engineer or designee and complies with the City Engineer's standards on construction, irrigation, location, and plant type;
2. All vegetation complies with the standards of Section 7.6.4, Landscaping Standards; and,
3. The landscaping does not interfere with the use of the sidewalk.
Obtain permission for the use of ROW and add the appropriate notes on landscape plans.
Ensure that all Zoning and Engineering comments and concerns are addressed prior to landscape approval.
Additional comments may apply.
12/08/2016 LOREN MAKUS ENGINEERING REVIEW Reqs Change 1. The DDO, TSMR and DRB processes must be completed and any conditions of approval must be included on the plans. Include the T16SAxxxx numbers for the special processes along with the other case numbers for reference.
2. Ensure all keynote and callouts have been revised to maintain consistency.
12/09/2016 ZELIN CANCHOLA COT NON-DSD TRAFFIC Approved
12/13/2016 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Reqs Change This review has been completed and resubmittal is required. Please resubmit the following items:

1) Two rolled sets of the plans
2) All approved documents submitted previously
3) All items requested by review staff
4) All items needed to approve these plans

Final Status

Task End Date Reviewer's Name Type of Review Description
12/13/2016 KROBLES1 OUT TO CUSTOMER Completed