Permit Number: DP14-0146
Parcel: 10408075Q

Address:
4421 N ORACLE RD

Review Status: Completed

Review Details: DEV PKG - RESUBMITTAL

Permit Number - DP14-0146
Review Name: DEV PKG - RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
11/07/2014 AROMERO4 START PLANS SUBMITTED Completed
11/14/2014 MARTIN BROWN COT NON-DSD FIRE Approved
12/02/2014 RONALD BROWN ZONING HC REVIEW Reqs Change SHEET C1.3
1. At note 18 delete all references to ADAAG.
a. The governing accessibility code is the 2012 IBC, Chapter 11 and the 2009 ICC A117.1.
b. All ramps are to be as per the 2009 ICC A117.1, Sections 405 and/or 406 as applicable.
c. Detectable warnings strips (truncated domes) are required at transportation platforms only.
2. Add another note 23: "All accessible route slopes are to comply with the 2009 ICC A117.1, Section 403.3; 5% maximum running slope and 2% maximum cross slopes."
SHEET C3.1
3. The "F" note reference at the accessible parking ramps should reference to the accessible parking blow up datail on sheet 7.2.
SHEET C7.1
4. At the accessible ramp in sidewalk detail:
a. Reference comment 1c above. They may be installed at the owner's option and if so must follow the requirements of the 2009 ICC A117.1, Sections 406.12, 13, 14 and 705 as applicable.
END OF REVIEW
12/02/2014 MICHAEL ST. PAUL ZONING REVIEW Approved
12/05/2014 ANDREW CONNOR LANDSCAPE REVIEW Reqs Change Identification and Descriptive Data

All improvements and site information, such as adjacent rights-of-way and property lines, shown on the landscape plan will be identical in size and location to those shown on the base plan (site plan or tentative plat). Should amendments be required to the base plan through the review process, the same amendments will be made to the landscape plan which will then be resubmitted along with the base plan.

LANDSCAPING AND SCREENING

Minimum Width
The street landscape border is a minimum of ten feet wide. Dimension street landscape orders on Oracle & Wetmore Rd's

Street landscape borders must be located entirely on site, except that, if approved by the City Engineer or designee, up to five feet of the required ten foot width may be placed within the adjacent right-of-way area or within the Major Streets and Routes (MS&R) right-of-way area on MS&R streets. Use of ROW on Oracle Rd will require ADOT approval.

Inorganic Ground Cover
Except as otherwise provided by this section, the area between the right-of-way line and sidewalk and the area between the sidewalk and the curb, if not covered with vegetation, must be covered with an appropriate inorganic ground cover, such as decomposed granite.

Continuous screens along street frontages for vehicle use area must be as determined by Table 7.6.4-I. Provide appropriate screening. Identify screening elements.

Vegetative Screens

Vegetation used to meet the screening standards is not included in the ground cover calculation as provided in Section 5-01.5.3, Calculation of Plant Growth Coverage.

Hedges and other vegetative screens may not extend more than three feet into the street landscape border

Ensure that all Zoning and Engineering comments and concerns are addressed.

Additional comments may apply
12/05/2014 TOM MARTINEZ OTHER AGENCIES AZ DEPT TRANSPORTATION Approved The Arizona Department of Transportation (ADOT) reviewed the response to our review comments below, and we have no further comments regarding the Development Plans for the proposed Longhorn Steakhouse to be located on the west side of SR 77 (Oracle Road) north of the Oracle Road/Wetmore Road intersection.

Thank you for the opportunity to comment on the Development Plans. We are looking forward to working with the City of Tucson towards the satisfactory completion of the development.

Maria Deal
Transportation Engineering Specialist

1221 S. 2nd Ave.
Tucson, AZ 85713
520.388.4235

mdeal@azdot.gov
12/08/2014 LOREN MAKUS ENGINEERING REVIEW Approved
12/09/2014 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Completed
12/10/2014 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Reqs Change This review has been completed and resubmittal is required. Please resubmit the following items:

1) Two rolled copies of the plans
2) All items requested by reveiw staff
3) All items needed to approve this plan

Final Status

Task End Date Reviewer's Name Type of Review Description
12/23/2014 FERNE RODRIGUEZ OUT TO CUSTOMER Completed