| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/05/2016 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Steve Shields Lead Planner PROJECT: West End Station Development Package (Revision) DP14-0041 TRANSMITTAL DATE: February 5, 2016 DUE DATE: Walk Through COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. 2-06.4.9.H.5 - If utilizing parking area access lanes (PAALs), they shall be designed in accordance with Section 7.4.6, Motor Vehicle Use Area Design Criteria, of the UDC. 1. COMMENT: Provide access lane width dimension for the east and west side access lanes shown in parking garage. 2-06.4.9.H.5.a - Show all motor vehicle off-street parking spaces provided, fully dimensioned. As a note, provide calculations on the number of spaces required (include the ratio used) and the number provided, including the number of spaces required and provided for the physically disabled. The drawing should indicate parking space locations for the physically disabled. A typical parking space detail shall be provided for both standard parking spaces and those for the physically disabled. For information on parking requirements for the physically disabled, refer to adopted building and accessibility codes of the City of Tucson. Design criteria for parking spaces and access are located in Section 7.4.6, Motor Vehicle Use Area Design Criteria, of the UDC. 2. COMMENT: Provide a typical vehicle parking space detail on the plan. 3. COMMENT: Provide a large scale detail of the accessible parking spaces shown within the parking garage that shows all accessible requirements such as dimensions, markings, grade slopes, accessible parking aisle, signage, van accessible space and access to the accessible route. Per the 2012 IBC, Table 1106.1, the accessible vehicle parking space is required to be a van accessible parking space. Demonstrate on the detail that the accessible space meets the requirements of ICC A117.1, Section 502.2. Once the above comments have been addressed Zoning is will to provide an over-the-counter review. Call or email to schedule an appointment for this review. If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package |
| 02/05/2016 | SSHIELD1 | H/C SITE | REVIEW | Reqs Change | See Zoning comments |
| 02/05/2016 | LOREN MAKUS | ENGINEERING | REVIEW | Reqs Change | The proposed curb return radii for the driveway entrance to the garage don't meet the requirements of the TSM. Minimum radii must be 18 feet. (TSM 10-01.9.0 figure 6) |
| 02/08/2016 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Completed | |
| 02/08/2016 | KROBLES1 | ZONING-DECISION LETTER | WRITE DECISION LETTER | Reqs Change | This review has been completed and resubmittal is required. Please resubmit the following items: 2 rolled sets of the plans All items requested by review staff All items needed to approve the plans |
| 02/09/2016 | ZELIN CANCHOLA | COT NON-DSD | TRAFFIC | Approved | |
| 02/12/2016 | ANDREW CONNOR | NPPO | REVIEW | Approved | |
| 02/12/2016 | ANDREW CONNOR | LANDSCAPE | REVIEW | Reqs Change | Identification and Descriptive Data All improvements and site information, such as adjacent rights-of-way and property lines, shown on the landscape plan will be identical in size and location to those shown on the base plan (site plan or tentative plat). Should amendments be required to the base plan through the review process, the same amendments will be made to the landscape plan which will then be resubmitted along with the base plan. Ensure that all Zoning and Engineering comments and concerns are addressed. If all comments have been addressed over-the-counter review and approval can be provided. |
| 02/16/2016 | ARUIZ1 | DESIGN PROFESSIONAL | REVIEW | Reqs Change | Pending Design Professional and DRC approval |