Permit Review Detail
Review Status: Completed
Review Details: GRADING
Permit Number - DP13-0247
Review Name: GRADING
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/13/2014 | ELEIBOL1 | ENGINEERING | REVIEW | Approved | WASH-ERR Report accepted and approved for lot 57. The following 12 conditions apply to this grading permit DP13-0247: 1) Call for Pre-construction meeting. For a PDSD Engineering Inspection, call IVR (740-6970), or schedule with a Customer Service Representative at the Planning & Development Services Department - Angie 837-4917, or contact PDSD Engineering at 837-4888, or schedule inspections online at: http://www.ci.tucson.az.us/dsd/Online_Services/Online_Permits/online_permits.html 2) Copy of approved plan/permit DP13-0247 shall be kept at site at all times until final grading approval. 3) These sets of plans act as the approved final grading plans for Wildcat Pass Lot 57 custom grading per approved plans sealed by Tim Robertson, R.A. 4) There shall be no disturbance outside of the disturbance/grading limits as shown on approved grading plans. Disturbance outside these limits may result in Stop Work Order, fines, and / or require revised plan submittal & review. Temporary fencing is required at east and north disturbance limits. 5) PDSD Inspector shall be called to inspect special grading such as temporary fencing, retaining wall, and cut / fill slopes when under construction. 6) Applicant / contractor shall assure north wall system is constructed from south side, without disturbance to north of north wall system. Stop Work Order may be issued if non-compliant. 7) Contact Permits and Codes (837-6606) for any questions regarding City of Tucson right-of-way permit requirements. 8) If grading construction is expected to last longer than the expiration date of the grading permit, contact PDSD to renew/extend the Grading Permit. If Final Grading Inspection has not been completed before the Grading Permit expires, and the permit has not been renewed, additional fees and reviews may be required. 9) Revisions to the design must be discussed with a Civil Engineer at the City of Tucson Planning & Development Services Department Engineering Division, prior to any construction activity, to determine whether additional details, calculations, drainage report, or a revised grading plan is needed, or, whether changes may be provided on as-builts. All work completed without approval is subject to Stop Work Order. 10) Permittee shall notify the PDSD when the grading operation is ready for final grading inspection. Final grading approval shall not be given until all work, including installation of all drainage improvements and their permanent protective devices, and all permanent erosion control measures have been completed in accordance with the approved grading plan and grading permit, and all conditions of permit are completed. Any revegetated areas shall require Landscaping approval of established vegetation prior to Final Grading Approval. Any other exposed areas that are not reseeded shall be covered in gravel or hand placed rip rap, unless other material is proposed, reviewed, and accepted by City of Tucson. 11) Temporary erosion and sediment control devices may be placed at locations where stormwater runoff exits grading limits to prevent debris, construction silt, and/or chemicals from entering streets or any drainage ways. Any interim erosion and sediment controls that are installed should be maintained, per approved grading plans or per EOR, at downstream areas of disturbance limits. These interim controls must be removed after all permanent controls have been established. 12) Final Revised Grading Plan (as-builts) is required to be submitted prior to final Grading Inspection. As-builts should include as-built elevations for finished pad grades, front of driveway at street elevation, retaining wall elevations, and other areas as deemed needed by surveyor. |
| 02/13/2014 | MICHAEL ST. PAUL | ZONING | REVIEW | Approved | |
| 02/13/2014 | ANDREW CONNOR | NPPO | REVIEW | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 01/27/2015 | KROBLES1 | OUT TO CUSTOMER | Completed |