Permit Number: DP13-0208
Parcel: 13315321A

Address:
2140 N KOLB RD

Review Status: Completed

Review Details: RESUB - SITE and/or GRADING

Permit Number - DP13-0208
Review Name: RESUB - SITE and/or GRADING
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/14/2014 RONALD BROWN HC SITE REVIEW Reqs Change 1. Provide 1 van accessible self service vaccuum parking space including signage.
a. Provide a large scale detail of this accessible space showing all accessible requirements as per the 2012 IBC, Chpater 11 and 2009 ICC A117.1.
2. A building permit will be required for the new canopies. Code requires a 1 hour fire separation rcmu fence between the new canopy that is within 10' of the property line, 2012 IBC, Table 602. This has not addressed with this transubmittal. Please do so. A section showing the height of the fence in relationship to the canopy would be nice.
SHEETS 2, 3 AND 4
3. At detail "E" and the Site Plan on Sheets 2 and 3:
a. Either change the flared sides of the curb to a slope of 1:10 maximum or delete the flared sides all together and provide a return curb.
END OF REVIEW
01/16/2014 ANDREW CONNOR LANDSCAPE REVIEW Approv-Cond Ensure that all Zoning comments and concerns are addressed prior NPP / Landscape approval signature.
01/17/2014 MICHAEL ST. PAUL ZONING REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
01/23/2014 CPIERCE1 REJECT SHELF Completed