Review Details: SITE and/or GRADING
Permit Number - DP13-0170
Review Name: SITE and/or GRADING
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/17/2013 | JOE LINVILLE | LANDSCAPE | REVIEW | Denied | 1) Revise the site plan clarify compliance with landscape regulations in effect when the site received Zoning approval and subsequent approved changes. LUC 3.7.1.2 Label and dimension the landscape planter areas. The minimum requirement for this site is to have landscape area equal to 5 feet times the length of the street frontage. Provide calculations for landscape area. There also was a requirement provide a 3' high screen hedge or fence along the street frontage adjacent to any parking lot. 2) Clarify the conditions for the curb cut and driveway along 1st Ave. There was a plan approved for the curb cut and the existing landscape area between the 2 drives. Revise the site plan demonstrate that the driveway does not exceed the maximum width TCC Ch 25 Art. 1, Sec 25-39 Sec. 25-39. Special requirements in business districts. Curb cuts and driveways shall conform to the following requirements in all business zoned districts: Maximum curb cut width . . . . . 35 feet Maximum driveway width at the property line . . . . . 30 feet Minimum distance between curb cuts or driveways . . . . . 20 feet |
| 09/18/2013 | JOE LINVILLE | NPPO | REVIEW | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 09/19/2013 | CPIERCE1 | REJECT SHELF | Completed |