The login landing page when selecting 'View' is still occurring and is still pending further investigation. 

Permit Number: DP13-0162
Parcel: 127035560

Address:
5555 E 5TH ST

Review Status: Completed

Review Details: RESUB - SITE/GRADING ALL

Permit Number - DP13-0162
Review Name: RESUB - SITE/GRADING ALL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/27/2013 MARTIN BROWN FIRE REVIEW Approved
09/27/2013 DAVID RIVERA ZONING REVIEW Approved
10/14/2013 ANDREW CONNOR LANDSCAPE REVIEW Approved
10/15/2013 RONALD BROWN H/C SITE REVIEW Denied SHEET 1
1. Provide dimensions for all accessible parking spaces.
2. At the curb ramp next to 5th Street, delete the flared sides and provide return curbs.
3. At the main entrance:
a. Provide an accessible passenger zone as per 2012 IBC, Section 1106.7 and ICC A117.1, Section 503.
b. Delete the curb ramp and raise the finished grade of the asphaltic paving under the porte cochere to the elevation of the main entrance.
4. At note 10 add the slope requirement of ICC A117.1, Sectionm 403.3; 5% maximum running slope and 2% maxium cross slope.
SHEET 3
5. At detail 12:
a. Add the 7'-0" above finished grade dimension to the bottom of the main sign.
b. Modify the location note to read that the accessible parking sign is to be located on the center line of the individual accessible parking space just behind the front face of the concrete curb, +/- 3" to 6".
END OF REVIEW
10/16/2013 JASON GREEN ENGINEERING REVIEW Approved DATE: October 18, 2013
SUBJECT: 5th Street and Jefferson Development Plan Package- 2nd Engineering Review
TO: ADG Inc.; Attn: David Garcia, RA
LOCATION: 5555 E 5th St; T14S R14E Sec12
REVIEWERS: Jason Green, CFM
ACTIVITY: DP13-0162


SUMMARY: Engineering Division of Planning & Development Services Department has received and reviewed the proposed Development Plan Package. Engineering Division does not recommend approval of the Development Plan Package at this time. This review falls under the Unified Development Code (UDC), Administration Manual (AM) and Technical Standards Manual (TSM). Refer to the following link for further clarification:
http://www.amlegal.com/nxt/gateway.dll/Arizona/tucson_az_udc/administrativemanual?f=templates$fn=default.htm$3.0$vid=amlegal:tucson_udc_az

The following items need to be addressed:

SITE PLAN:

1) Restated: AM Sec.2-06.4.9.R: It is acknowledged that a new pedestrian circulation path has been constructed from 5th St to the building that physically separates the parking spaces adjacent from the path; however due to the construction of the 6-inch curb the plan needs to verify the parking stall dimensions on both sides to ensure the minimum 8.5 foot width.

2) Restated: AM Sec.2-06.4.9.S: It is acknowledged that the development plan document has been revised to correctly label the proposed handicap access ramps within the public right-of-way; however it appears that the middle PAAL access point (eastern access point for the subject property) is missing the handicap access ramp along the east side of the entry. Revise the document to include the ramp on both sides of the access point.

GENERAL COMMENTS:

Please provide a revised Development Plan Package that addresses the comment provided above. For expedite purposes the development plan package can be reviewed over the counter (PDSD Engineering Division comment only) for stamp approval once all items have been addressed. Please call to schedule an appointment when ready.

For any questions or to schedule meetings call me at 837-4929.



Jason Green, CFM
Senior Engineer Associate
Engineering Division
Planning & Development Services Department
10/18/2013 CPIERCE1 PLUMBING-COMMERCIAL REVIEW Needs Review