Permit Number: DP13-0157
Parcel: 125101400

Review Status: Completed

Review Details: DEV PKG - RESUBMITTAL

Permit Number - DP13-0157
Review Name: DEV PKG - RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/19/2013 CPIERCE1 START PLANS SUBMITTED Completed
09/23/2013 RONALD BROWN ZONING HC REVIEW Denied 1. Complete the marked crossing in front of the dumpster area by providing painted stripes defining the crossing area.
09/23/2013 KBROUIL1 COT NON-DSD FIRE Approved
09/23/2013 DAVID RIVERA ZONING REVIEW Reqs Change CDRC TRANSMITTAL

TO: Development Services Department Plans Coordination Office
FROM: David Rivera
Principal Planner

PROJECT: DP13-0157
3601 E Broadway Blvd.
Cheddar's Restaurant - Food Service Use
Development Package

TRANSMITTAL DATE: September 23, 2013

DUE DATE: October 3, 2013

COMMENTS: Please resubmit final sign off copies with the sequence numbers for the CC&R's and the plat. The remaining comments are from the last review which could not be addressed at this time. The recordation information must be noted on the DP and final plat.

This plan has been reviewed for compliance with the Development Package Standards listed in section 2-06 of the City of Tucson Administrative Manual. Also compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC).

The review comments include the actual standard first with the applicable Administrative Manual section number and the following paragraph is the actual comment related to the specific item that must be addressed. If you need to review the sections listed below click on the link or copy it in the address bar of your internet program. http://www.amlegal.com/nxt/gateway.dll/Arizona/tucson_az_udc/administrativemanual?f=templates$fn=default.htm$3.0$vid=amlegal:tucson_udc_az

This link will take you directly to the section used for the standards review. The UDC requirements are in the Unified Development Code and can be viewed at the same web link as above.

1. Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is August 19, 2014.
and,

2-06.4.0 CONTENT REQUIREMENTS

2-06.4.7 - General Notes
The following general notes are required. Additional notes specific to each plan are required where applicable.

2-06.4.7.A - Zoning and Land Use Notes

2-06.4.7.A.7 - If the property is part of a subdivision plat that is being reviewed or has been recorded, provide the case number in the lower right corner of each sheet. As a general note, indicate whether the project is part of a Flexible Lot Development (FLD), condominium, or another similar type project.

COMMENT: The legal description of the parcel in question may have to be revised if this development package is not approved prior to the recordation of the Subdivision plat S13-016. If the subdivision plat is approved and recorded after the approval of this development package the legal description may remain as noted in the title block.

2-06.4.7.A.8 - For development package documents provide:


2-06.4.8 - Existing Site Conditions

2-06.4.8.A - Provide site boundary/subdivision perimeter information, including bearing in degrees, minutes, and seconds, with basis for bearing noted, together with distances in feet, to hundredths of a foot, or other functional reference system.

COMMENT: As mentioned in a comment above, there is a subdivision plat that is in process fore review, approval and eventual recordation. If the plat is approved before this development package is approved, the overall parcel and boundary (distance and bearing) of the parcel will have to be drawn and labeled on the development package plans.

If you have any questions about this transmittal, please call David Rivera, (520) 791-5608.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package site plan and any requested documents.
09/23/2013 JENNIFER STEPHENS PIMA COUNTY ADDRESSING Approved MICHELENE NOWAK
ADDRESSING REVIEW
PH #: 721-9512



TO:

CITY PLANNING

FROM:

MICHELENE NOWAK, ADDRESSING REVIEW

SUBJECT:

DP13-0157/CHEDDERS AT ELCON (PAD 3) 2nd REVIEW

DATE:

SEPTEMBER 23, 2013



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project.

1.) Submit a 24 x 36 Reverse Reading Double Matte Photo Mylar or bond paper of approved Development Plan to City Planning. Signed and dated Mylar will be forwarded to Pima County Addressing prior to assignment of addresses.

2.) All addresses will need to be displayed per Pima County Address Standards at the time of final inspection.




***The Pima County Addressing Section can use digital CAD drawing files when
submitted with your final plat Mylar. These CAD files can be submitted through Pima
County Addressing. The digital CAD drawing files expedite the addressing
and permitting processes when we are able to insert this digital data into the County's
Geographic Information System. Your support is greatly appreciated.***
09/27/2013 ANDREW CONNOR LANDSCAPE REVIEW Approv-Cond All improvements and site information, such as adjacent rights-of-way and property lines, shown on the landscape plan will be identical in size and location to those shown on the base plan (site plan or tentative plat). Should amendments be required to the base plan through the review process, the same amendments will be made to the landscape plan which will then be resubmitted along with the base plan.

Ensure that all Zoning & Engineering comments and concerns are addressed prior NPP / Landscape approval signature.
10/03/2013 LOREN MAKUS ENGINEERING REVIEW Approved
10/04/2013 PGEHLEN1 ENV SVCS REVIEW Reqs Change · The plans provided show a structural tube over the top of the gates and a roof over the compactor/recycle enclosure. Please revise the plans to provide the twenty-five (25) foot minimum height clearance over the collection area. TSM Section 8.01.6.2.C



· The dimensions and clearances inside the enclosure for the compactor and recycling container must comply with Figure 3A of TSM Section 8.01. The enclosure shall have a minimum ten (10) foot by ten (10) foot unobstructed interior space per compactor and container within the bollards. Also, show how the gates will be securable in the open position.



· Show the required 10 ft. wide concrete service apron in front of the enclosure, and call out its six (6) inch thickness and reinforcement.



If there are questions, contact me at kperry@perryengineering.net
10/04/2013 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Reqs Change This review has been completed and resubmittal is required. Please include the following items:

1) 3 sets of the rolled plans
2) a disk containing all items submitted.
3) all items requested by review staff
4) all items needed to approve these plans.

Final Status

Task End Date Reviewer's Name Type of Review Description
10/24/2013 SHANAE POWELL OUT TO CUSTOMER Completed
10/24/2013 CPIERCE1 REJECT SHELF Completed